Attenuation Correction Methods Suitable for Brain Imaging with a PET/MRI Scanner: A Comparison of Tissue Atlas and Template Attenuation Map Approaches

被引:70
|
作者
Malone, Ian B. [1 ]
Ansorge, Richard E. [1 ]
Williams, Guy B. [2 ]
Nestor, Peter J. [3 ]
Carpenter, T. Adrian [2 ]
Fryer, Tim D. [2 ]
机构
[1] Univ Cambridge, Cavendish Lab, Cambridge CB3 0HE, England
[2] Univ Cambridge, Addenbrookes Hosp, Dept Clin Neurosci, Wolfson Brain Imaging Ctr, Cambridge CB3 0HE, England
[3] Univ Cambridge, Addenbrookes Hosp, Dept Clin Neurosci, Neurol Unit, Cambridge CB3 0HE, England
基金
英国工程与自然科学研究理事会; 英国医学研究理事会;
关键词
attenuation correction; brain; nonrigid registration; PET/MRI scanner; CEREBRAL 3D PET; IMAGES;
D O I
10.2967/jnumed.110.085076
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Modeled attenuation correction (AC) will be necessary for combined PET/MRI scanners not equipped with transmission scanning hardware. We compared 2 modeled AC approaches that use nonrigid registration with rotating Ge-68 rod-based measured AC for 10 subjects scanned with F-18-FDG. Methods: Two MRI and attenuation map pairs were evaluated: tissue atlas-based and measured templates. The tissue atlas approach used a composite of the BrainWeb and Zubal digital phantoms, whereas the measured templates were produced by averaging spatially normalized measured MR image and coregistered attenuation maps. The composite digital phantom was manually edited to include 2 additional tissue classes (paranasal sinuses, and ethmoidal air cells or nasal cavity). In addition, 3 attenuation values for bone were compared. The MRI and attenuation map pairs were used to generate subject-specific attenuation maps via nonrigid registration of the MRI to the MR image of the subject. SPM2 and a B-spline free-form deformation algorithm were used for the nonrigid registration. To determine the accuracy of the modeled AC approaches, radioactivity concentration was assessed on a voxelwise and regional basis. Results: The template approach produced better spatial consistency than the phantom-based atlas, with an average percentage error in radioactivity concentration across the regions, compared with measured AC, of -1.2% +/- 1.2% and 1.5% +/- 1.9% for B-spline and SPM2 registration, respectively. In comparison, the tissue atlas method with B-spline registration produced average percentage errors of 0.0% +/- 3.0%, 0.9% +/- 2.9%, and 2.9% +/- 2.8% for bone attenuation values of 0.143 cm(-1), 0.152 cm(-1), and 0.172 cm(-1), respectively. The largest errors for the template AC method were found in parts of the frontal cortex (-3%) and the cerebellar vermis (-5%). Intersubject variability was higher with SPM2 than with B-spline. Compared with measured AC, template AC with B-spline and SPM2 achieved a correlation coefficient (R-2) of 0.99 and 0.98, respectively, for regional radioactivity concentration. The corresponding R-2 for the tissue atlas approach with B-spline registration was 0.98, irrespective of the bone attenuation coefficient. Conclusion: Nonrigid registration of joint MRI and attenuation map templates can produce accurate AC for brain PET scans, particularly with measured templates and B-spline registration. Consequently, these methods are suitable for AC of brain scans acquired on combined PET/MRI systems.
引用
收藏
页码:1142 / 1149
页数:8
相关论文
共 50 条
  • [21] Importance of gender and BMI in atlas design for PET/MRI attenuation correction
    Patrick, John
    Marshall, Harry
    Sabondjian, Eric
    Butler, John
    Theberge, Jean
    Thompson, Robert
    Prato, Frank
    Stodilka, Robert
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [22] CT Based Attenuation Correction for PET Brain Imaging
    Lokitz, Stephen J.
    Coleman, R. Edward
    Yoshizumi, Terry T.
    Toncheva, Greta I.
    Daigle, Lauren T.
    Colsher, James G.
    Turkington, Timothy G.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3320 - 3325
  • [23] Comparison of template-guided and calculated attenuation corrections in FDG brain PET imaging
    Kim, Jin Su
    Lee, Jae Sung
    Kirn, Kyeong Min
    Cheon, Gi Jeong
    Song, In Chan
    Lee, Dong Soo
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [24] Comparison of MRI-guided attenuation correction strategies in PET/MRI
    Arabi, Hossein
    Rager, Olivier
    Alem, Asma
    Varoquaux, Arthur
    Becker, Minerva
    Zaidi, Habib
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [25] Three MRI-based attenuation correction methods for PET
    Marshall, Harry
    Laidley, David
    Patrick, John
    Butler, John
    Thompson, Robert
    Prato, Frank
    Rachinsky, Irina
    Stodilka, Robert
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [26] An automatic pipeline for PET/MRI attenuation correction validation in the brain
    Mahdjoub Hamdi
    Chunwei Ying
    Hongyu An
    Richard Laforest
    EJNMMI Physics, 10
  • [27] An automatic pipeline for PET/MRI attenuation correction validation in the brain
    Hamdi, Mahdjoub
    Ying, Chunwei
    An, Hongyu
    Laforest, Richard
    EJNMMI PHYSICS, 2023, 10 (01)
  • [28] EVALUATION OF SEVERAL MULTI-ATLAS METHODS FOR PSEUDO-CT GENERATION IN BRAIN MRI-PET ATTENUATION CORRECTION
    Merida, Ines
    Costes, Nicolas
    Heckemann, Rolf A.
    Drzezga, Alexander
    Forster, Stefan
    Hammers, Alexander
    2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI), 2015, : 1431 - 1434
  • [29] Template based attenuation correction for brain MR-PET scanners
    Kops, E. Rota
    Herzog, H.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2009, 29 : S337 - S337
  • [30] Evaluation of Atlas-Based Attenuation Correction for Integrated PET/MR in Human Brain: Application of a Head Atlas and Comparison to True CT-Based Attenuation Correction
    Sekine, Tetsuro
    Buck, Alfred
    Delso, Gaspar
    ter Voert, Edwin E. G. W.
    Huellner, Martin
    Veit-Haibach, Patrick
    Warnock, Geoffrey
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (02) : 215 - 220