Attenuation Correction Methods Suitable for Brain Imaging with a PET/MRI Scanner: A Comparison of Tissue Atlas and Template Attenuation Map Approaches

被引:70
|
作者
Malone, Ian B. [1 ]
Ansorge, Richard E. [1 ]
Williams, Guy B. [2 ]
Nestor, Peter J. [3 ]
Carpenter, T. Adrian [2 ]
Fryer, Tim D. [2 ]
机构
[1] Univ Cambridge, Cavendish Lab, Cambridge CB3 0HE, England
[2] Univ Cambridge, Addenbrookes Hosp, Dept Clin Neurosci, Wolfson Brain Imaging Ctr, Cambridge CB3 0HE, England
[3] Univ Cambridge, Addenbrookes Hosp, Dept Clin Neurosci, Neurol Unit, Cambridge CB3 0HE, England
基金
英国工程与自然科学研究理事会; 英国医学研究理事会;
关键词
attenuation correction; brain; nonrigid registration; PET/MRI scanner; CEREBRAL 3D PET; IMAGES;
D O I
10.2967/jnumed.110.085076
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Modeled attenuation correction (AC) will be necessary for combined PET/MRI scanners not equipped with transmission scanning hardware. We compared 2 modeled AC approaches that use nonrigid registration with rotating Ge-68 rod-based measured AC for 10 subjects scanned with F-18-FDG. Methods: Two MRI and attenuation map pairs were evaluated: tissue atlas-based and measured templates. The tissue atlas approach used a composite of the BrainWeb and Zubal digital phantoms, whereas the measured templates were produced by averaging spatially normalized measured MR image and coregistered attenuation maps. The composite digital phantom was manually edited to include 2 additional tissue classes (paranasal sinuses, and ethmoidal air cells or nasal cavity). In addition, 3 attenuation values for bone were compared. The MRI and attenuation map pairs were used to generate subject-specific attenuation maps via nonrigid registration of the MRI to the MR image of the subject. SPM2 and a B-spline free-form deformation algorithm were used for the nonrigid registration. To determine the accuracy of the modeled AC approaches, radioactivity concentration was assessed on a voxelwise and regional basis. Results: The template approach produced better spatial consistency than the phantom-based atlas, with an average percentage error in radioactivity concentration across the regions, compared with measured AC, of -1.2% +/- 1.2% and 1.5% +/- 1.9% for B-spline and SPM2 registration, respectively. In comparison, the tissue atlas method with B-spline registration produced average percentage errors of 0.0% +/- 3.0%, 0.9% +/- 2.9%, and 2.9% +/- 2.8% for bone attenuation values of 0.143 cm(-1), 0.152 cm(-1), and 0.172 cm(-1), respectively. The largest errors for the template AC method were found in parts of the frontal cortex (-3%) and the cerebellar vermis (-5%). Intersubject variability was higher with SPM2 than with B-spline. Compared with measured AC, template AC with B-spline and SPM2 achieved a correlation coefficient (R-2) of 0.99 and 0.98, respectively, for regional radioactivity concentration. The corresponding R-2 for the tissue atlas approach with B-spline registration was 0.98, irrespective of the bone attenuation coefficient. Conclusion: Nonrigid registration of joint MRI and attenuation map templates can produce accurate AC for brain PET scans, particularly with measured templates and B-spline registration. Consequently, these methods are suitable for AC of brain scans acquired on combined PET/MRI systems.
引用
收藏
页码:1142 / 1149
页数:8
相关论文
共 50 条
  • [31] Evaluation of zero-echo-time attenuation correction for integrated PET/MR brain imaging—comparison to head atlas and 68Ge-transmission-based attenuation correction
    João M. Sousa
    Lieuwe Appel
    Mathias Engström
    Stergios Papadimitriou
    Dag Nyholm
    Elna-Marie Larsson
    Håkan Ahlström
    Mark Lubberink
    EJNMMI Physics, 5
  • [32] Attenuation correction for myocardial perfusion imaging - A comparison between SPECT and PET imaging by polar map analysis
    Graf, S.
    Khorsand, A.
    Stix, G.
    Nekolla, S.
    Becherer, A.
    Kletter, K.
    Dudczak, R.
    Sochor, H.
    Maurer, G.
    Parenta, G.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2006, 45 (04): : 171 - 176
  • [33] Hybrid segmentation-atlas method for PET-MRI attenuation correction
    Tanigawa, Asuka
    Yamaya, Taiga
    Kawaguchi, Hiroshi
    Hirano, Oshiyuki
    Shiraishi, Takahiro
    Tanimoto, Katsuyuki
    Yoshida, Eiji
    Ito, Hiroshi
    Obata, Takayuki
    Suga, Mikio
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2727 - 2729
  • [34] The Role of Body Mass and Gender in Atlas Construction for Attenuation Correction in PET/MRI
    Patrick, J.
    Marshall, H.
    Sabondjian, E.
    Butler, J.
    Rachinsky, I.
    Thompson, T.
    Theberge, J.
    Prato, F.
    Stodilka, R.
    MEDICAL PHYSICS, 2012, 39 (07) : 4641 - 4641
  • [35] Assessment of attenuation correction for myocardial PET imaging using combined PET/MRI
    Martin Lyngby Lassen
    Sazan Rasul
    Dietrich Beitzke
    Marie-Elisabeth Stelzmüller
    Jacobo Cal-Gonzalez
    Marcus Hacker
    Thomas Beyer
    Journal of Nuclear Cardiology, 2019, 26 : 1107 - 1118
  • [36] Assessment of attenuation correction for myocardial PET imaging using combined PET/MRI
    Lassen, Martin Lyngby
    Rasul, Sazan
    Beitzke, Dietrich
    Stelzmueller, Marie-Elisabeth
    Cal-Gonzalez, Jacobo
    Hacker, Marcus
    Beyer, Thomas
    JOURNAL OF NUCLEAR CARDIOLOGY, 2019, 26 (04) : 1107 - 1118
  • [37] Low Dose CT Attenuation Correction for Brain imaging with PET
    Bonab, A. A.
    Alpert, N. M.
    Liu, B.
    Fischman, A. J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S258 - S258
  • [38] Evaluation of calculated attenuation correction method in brain PET imaging
    Da Costa, A.
    Cassol, E.
    Arribarat, G.
    Peran, P.
    Blanc, P.
    Hitzel, A.
    Payoux, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S561 - S561
  • [39] Automated PET attenuation correction model for functional brain imaging
    Weinzapfel, BT
    Hutchins, GD
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (03) : 483 - 491
  • [40] Pseudo-CT generation in brain MR-PET attenuation correction: comparison of several multi-atlas methods
    Ines Merida
    Nicolas Costes
    Rolf Heckemann
    Alexander Hammers
    EJNMMI Physics, 2 (Suppl 1)