Attenuation correction for the NIH ATLAS small animal PET scanner

被引:0
|
作者
Yao, RT [1 ]
Seidel, R [1 ]
Liow, JS [1 ]
Green, MV [1 ]
机构
[1] SUNY Buffalo, Dept Nucl Med, Buffalo, NY 14214 USA
关键词
D O I
10.1109/NSSMIC.2003.1352353
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We evaluated two methods of attenuation correction for the NIH ATLAS small animal PET scanner: 1) a CT-based method that derives 511 keV attenuation coefficients (mu) by extrapolation from spatially registered CT images; and 2) an analytic method based on the body outline of emission images and an empirical mu. A specially fabricated attenuation calibration phantom with cylindrical inserts that mimic different body tissues was used to derive the relationship to convert CT values to mu for PET. The methods were applied to three test data sets: 1) a uniform cylinder phantom, 2) the attenuation calibration phantom and 3) a mouse injected with [F-18] FDG. The CT-based attenuation correction factors were larger in non-uniform regions of the imaging subject, e.g. mouse head, than the analytic method. The two methods had similar correction factors for regions with uniform density and detectable emission source distributions.
引用
收藏
页码:2283 / 2287
页数:5
相关论文
共 50 条
  • [1] Attenuation correction for the NIH ATLAS small animal PET scanner
    Yao, RT
    Seidel, J
    Liow, JS
    Green, MV
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (03) : 664 - 668
  • [2] Features of the NIH atlas small animal PET scanner and its use with a coaxial small animal volume CT scanner
    Seidel, J
    Vaquero, JJ
    Pascau, J
    Desco, M
    Johnson, CA
    Green, MV
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 545 - 548
  • [3] Attenuation correction for small animal PET tomographs
    Chow, PL
    Rannou, FR
    Chatziioannou, AF
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (08): : 1837 - 1850
  • [4] Attenuation correction for pre-clinical PET images using a small animal CT scanner
    D'Ambrosio, D.
    Spinelli, A. E.
    Boschi, S.
    Quarta, C.
    Franchi, R.
    Pagotto, U.
    Marengo, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S227 - S228
  • [5] Attenuation correction for freely moving small animal brain PET studies based on a virtual scanner geometry
    Angelis, G. I.
    Kyme, A. Z.
    Ryder, W. J.
    Fulton, R. R.
    Meikle, S. R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (19): : 5651 - 5666
  • [6] Importance of Attenuation Correction (AC) for Small Animal PET Imaging
    El Ali, Henrik H.
    Bodholdt, Rasmus Poul
    Jorgensen, Jesper Tranekjr
    Myschetzky, Rebecca
    Kjaer, Andreas
    DIAGNOSTICS, 2012, 2 (04) : 42 - 51
  • [7] A single slice rebinning/2D exact positioning OSEM reconstruction for the NIH ATLAS small animal PET scanner.
    Liow, J
    Seidel, J
    Johnson, CA
    Toyama, H
    Green, MV
    Innis, RB
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 163P - 163P
  • [8] Quantification accuracy and partial volume effect in dependence of the attenuation correction of a state-of-the-art small animal PET scanner
    Mannheim, Julia G.
    Judenhofer, Martin S.
    Schmid, Andreas
    Tillmanns, Julia
    Stiller, Detlef
    Sossi, Vesna
    Pichler, Bernd J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (12): : 3981 - 3993
  • [9] A Wearable Small Animal PET Scanner
    Yu, Xin
    Liu, Han
    Zhu, Wenjing
    Liang, Da
    Zhao, Huiping
    Zhu, Zhiliang
    Tao, Jinyong
    Zeng, Jiayang
    Zhang, Yibin
    Xu Jianfeng
    Xie, Siwei
    Peng, Qiyu
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [10] Resolution uniformity and sensitivity of the NIH ATLAS small animal PET scanner: Comparison to simulated LSO scanners without depth-of-interaction capability
    Seidel, J
    Vaquero, JJ