Attenuation correction for the NIH ATLAS small animal PET scanner

被引:0
|
作者
Yao, RT [1 ]
Seidel, R [1 ]
Liow, JS [1 ]
Green, MV [1 ]
机构
[1] SUNY Buffalo, Dept Nucl Med, Buffalo, NY 14214 USA
关键词
D O I
10.1109/NSSMIC.2003.1352353
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We evaluated two methods of attenuation correction for the NIH ATLAS small animal PET scanner: 1) a CT-based method that derives 511 keV attenuation coefficients (mu) by extrapolation from spatially registered CT images; and 2) an analytic method based on the body outline of emission images and an empirical mu. A specially fabricated attenuation calibration phantom with cylindrical inserts that mimic different body tissues was used to derive the relationship to convert CT values to mu for PET. The methods were applied to three test data sets: 1) a uniform cylinder phantom, 2) the attenuation calibration phantom and 3) a mouse injected with [F-18] FDG. The CT-based attenuation correction factors were larger in non-uniform regions of the imaging subject, e.g. mouse head, than the analytic method. The two methods had similar correction factors for regions with uniform density and detectable emission source distributions.
引用
收藏
页码:2283 / 2287
页数:5
相关论文
共 50 条
  • [41] Raytest ClearPET™, a new generation small animal PET scanner
    Roldan, P. Sempere
    Chereul, E.
    Dietzel, O.
    Magnier, L.
    Pautrot, C.
    Rbah, L.
    Sappey-Marinier, D.
    Wagner, A.
    Zimmer, L.
    Janier, M.
    Tarazona, V.
    Dietzel, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2): : 498 - 501
  • [42] Performance evaluation of the Philips MOSAIC small animal PET scanner
    Marc C. Huisman
    Sybille Reder
    Axel W. Weber
    Sibylle I. Ziegler
    Markus Schwaiger
    European Journal of Nuclear Medicine and Molecular Imaging, 2007, 34 : 532 - 540
  • [43] Micropet: A dedicated PET scanner for small animal imaging.
    Cherry, SR
    Shao, Y
    Silverman, RW
    Siegel, S
    Meadors, K
    Mumcuoglu, E
    Young, J
    Jones, WF
    Moyers, C
    Andreaco, M
    Paulus, M
    Binkley, D
    Nutt, R
    Phelps, ME
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 334 - 334
  • [44] Temperature Dependence of the LabPET Small-Animal PET Scanner
    Keereman, Vincent
    Vanhove, Christian
    Van Holen, Roel
    Vandenberghe, Stefaan
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2896 - 2901
  • [45] Importance of gender and BMI in atlas design for PET/MRI attenuation correction
    Patrick, John
    Marshall, Harry
    Sabondjian, Eric
    Butler, John
    Theberge, Jean
    Thompson, Robert
    Prato, Frank
    Stodilka, Robert
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [46] The ClearPET™ neuro scanner:: A dedicated LSO/LuYAP phoswich small animal PET scanner
    Ziemons, K
    Achten, R
    Auffray, E
    Bauer, A
    Brandenburg, G
    Bruyndonckx, P
    Choi, Y
    Daemen, J
    Dehnhardt, M
    Devroede, O
    Fleischer, M
    Fuss, L
    Heinrichs, U
    Hollendung, A
    Holschbach, M
    Khodaverdi, M
    Kirchner, P
    Kleines, H
    Krieguer, M
    Larue, H
    Lecoq, P
    Leyendecker, M
    Moeller, R
    Morel, C
    Mosset, JB
    Parl, C
    Pietrzyk, U
    Schmitz, J
    Streun, M
    Tavernier, S
    Veggian, M
    Zimmermann, E
    Coenen, HH
    Halling, H
    Sievering, R
    Zilles, K
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2430 - 2433
  • [47] Correction for continuous motion in small animal PET
    Zhou, Victor W.
    Kyme, Andre Z.
    Meikle, Steven R.
    Lehnert, Wencke
    Fulton, Roger
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4725 - +
  • [48] Evaluation of transmission methodology and attenuation correction for the microPET Focus 220 animal scanner
    Lehnert, Wencke
    Meikle, Steven R.
    Siegel, Stefan
    Newport, Danny
    Banati, Richard B.
    Rosenfeld, Anatoly B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (16): : 4003 - 4016
  • [49] Registration of high resolution, small animal CT and PET images for visualization, quantification, and attenuation correction.
    Miller, MA
    Rouze, NC
    Hutchins, GD
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 115P - 115P
  • [50] Preclinical Evaluation of MR Attenuation Correction Versus CT Attenuation Correction on a Sequential Whole-Body MR/PET Scanner
    Bini, Jason
    Izquierdo-Garcia, David
    Mateo, Jesus
    Machac, Josef
    Narula, Jagat
    Fuster, Valentin
    Fayad, Zahi A.
    INVESTIGATIVE RADIOLOGY, 2013, 48 (05) : 313 - 322