Evaluation of transmission methodology and attenuation correction for the microPET Focus 220 animal scanner

被引:25
|
作者
Lehnert, Wencke
Meikle, Steven R.
Siegel, Stefan
Newport, Danny
Banati, Richard B.
Rosenfeld, Anatoly B.
机构
[1] Univ Sydney, Fac Hlth Sci, Sch Med Radiat Sci, Lidcombe, NSW 1825, Australia
[2] Brain & Mind Res Inst, Ramaciotti Imaging Ctr, Camperdown, NSW 2050, Australia
[3] Siemens Preclin Solut, Knoxville, TN 37932 USA
[4] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW 2522, Australia
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2006年 / 51卷 / 16期
关键词
D O I
10.1088/0031-9155/51/16/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An accurate, low noise estimate of photon attenuation in the subject is required for quantitative microPET studies of molecular tracer distributions in vivo. In this work, several transmission-based measurement techniques were compared, including coincidence mode with and without rod windowing, singles mode with two different energy sources (Ge-68 and Co-57), and postinjection transmission scanning. In addition, the effectiveness of transmission segmentation and the propagation of transmission bias and noise into the emission images were examined. The Co-57 singles measurements provided the most accurate attenuation coefficients and superior signal-to-noise ratio, while Ge-68 singles measurements were degraded due to scattering from the object. Scatter correction of Ge-68 transmission data improved the accuracy for a 10 cm phantom but over-corrected for a mouse phantom. Co-57 scanning also resulted in low bias and noise in postinjection transmission scans for emission activities up to 20 MBq. Segmentation worked most reliably for transmission data acquired with Co-57 but the minor improvement in accuracy of attenuation coefficients and signal-to-noise may not justify its use, particularly for small subjects. We conclude that Co-57 singles transmission scanning is the most suitable method for measured attenuation correction on the microPET Focus 220 animal scanner.
引用
收藏
页码:4003 / 4016
页数:14
相关论文
共 50 条
  • [1] Evaluation of transmission methodology for the microPET Focus 220 animal scanner
    Lehnert, Wencke
    Meikle, Steven R.
    Siegel, Stefan
    Bailey, David
    Banati, Richard
    Rosenfeld, Anatoly B.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2519 - 2523
  • [2] Count Rate Performance of the MicroPET Focus 220 Animal Scanner in Singles Transmission Scanning Mode
    Lehnert, Wencke
    Meikle, Steven R.
    Newport, Danny F.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (05) : 2493 - 2500
  • [3] Evaluation of the maximum a posteriori (MAP) reconstruction on a microPET Focus220 scanner
    Bao, Q.
    Bae, B.
    Li, Q.
    Smith, A. M.
    Vu, N.
    Chatziioannou, A.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3605 - +
  • [4] Performance evaluation of the microPET focus: A third-generation microPET scanner dedicated to animal imaging
    Tai, YC
    Ruangma, A
    Rowland, D
    Siegel, S
    Newport, DF
    Chow, PL
    Laforest, R
    JOURNAL OF NUCLEAR MEDICINE, 2005, 46 (03) : 455 - 463
  • [5] Count Rate Performance and Dead Time in Singles Transmission Scanning for the microPET Focus 220 Scanner
    Lehnert, Wencke
    Meikle, Steven R.
    Newport, Danny F.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2484 - 2487
  • [6] Impact of Detector Defects on Image Quality and Quantification for the microPET Focus 220 Scanner
    Lehnert, Wencke
    Meikle, Steven R.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3032 - 3036
  • [7] Transmission imaging and attenuation correction for the microPET® P4 tomograph
    Chow, PL
    Bai, B
    Siegel, S
    Leahy, RM
    Chatziioannou, AF
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1298 - 1302
  • [8] Image quality of Zr-89 PET imaging in the Siemens microPET Focus 220 preclinical scanner
    Tyler J. Bradshaw
    Martin J. Voorbach
    David R. Reuter
    Anthony M. Giamis
    Sarah R. Mudd
    John D. Beaver
    Molecular Imaging and Biology, 2016, 18 : 377 - 385
  • [9] Image quality of Zr-89 PET imaging in the Siemens microPET Focus 220 preclinical scanner
    Bradshaw, Tyler J.
    Voorbach, Martin J.
    Reuter, David R.
    Giamis, Anthony M.
    Mudd, Sarah R.
    Beaver, John D.
    MOLECULAR IMAGING AND BIOLOGY, 2016, 18 (03) : 377 - 385
  • [10] Attenuation correction for the NIH ATLAS small animal PET scanner
    Yao, RT
    Seidel, J
    Liow, JS
    Green, MV
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (03) : 664 - 668