Evaluation of transmission methodology and attenuation correction for the microPET Focus 220 animal scanner

被引:25
|
作者
Lehnert, Wencke
Meikle, Steven R.
Siegel, Stefan
Newport, Danny
Banati, Richard B.
Rosenfeld, Anatoly B.
机构
[1] Univ Sydney, Fac Hlth Sci, Sch Med Radiat Sci, Lidcombe, NSW 1825, Australia
[2] Brain & Mind Res Inst, Ramaciotti Imaging Ctr, Camperdown, NSW 2050, Australia
[3] Siemens Preclin Solut, Knoxville, TN 37932 USA
[4] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW 2522, Australia
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2006年 / 51卷 / 16期
关键词
D O I
10.1088/0031-9155/51/16/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An accurate, low noise estimate of photon attenuation in the subject is required for quantitative microPET studies of molecular tracer distributions in vivo. In this work, several transmission-based measurement techniques were compared, including coincidence mode with and without rod windowing, singles mode with two different energy sources (Ge-68 and Co-57), and postinjection transmission scanning. In addition, the effectiveness of transmission segmentation and the propagation of transmission bias and noise into the emission images were examined. The Co-57 singles measurements provided the most accurate attenuation coefficients and superior signal-to-noise ratio, while Ge-68 singles measurements were degraded due to scattering from the object. Scatter correction of Ge-68 transmission data improved the accuracy for a 10 cm phantom but over-corrected for a mouse phantom. Co-57 scanning also resulted in low bias and noise in postinjection transmission scans for emission activities up to 20 MBq. Segmentation worked most reliably for transmission data acquired with Co-57 but the minor improvement in accuracy of attenuation coefficients and signal-to-noise may not justify its use, particularly for small subjects. We conclude that Co-57 singles transmission scanning is the most suitable method for measured attenuation correction on the microPET Focus 220 animal scanner.
引用
收藏
页码:4003 / 4016
页数:14
相关论文
共 50 条
  • [21] Small animal tumour imaging with MRI and the ECAT EXACT scanner: application of partial volume correction and comparison with microPET data
    Helisch, Andreas
    Thews, Oliver
    Buchholz, Hans-Georg
    Tillmanns, Julia
    Kronfeld, Andrea
    Schreiber, Laura M.
    Schreckenberger, Mathias
    Bartenstein, Peter
    NUCLEAR MEDICINE COMMUNICATIONS, 2010, 31 (04) : 294 - 300
  • [22] Preclinical Evaluation of MR Attenuation Correction Versus CT Attenuation Correction on a Sequential Whole-Body MR/PET Scanner
    Bini, Jason
    Izquierdo-Garcia, David
    Mateo, Jesus
    Machac, Josef
    Narula, Jagat
    Fuster, Valentin
    Fayad, Zahi A.
    INVESTIGATIVE RADIOLOGY, 2013, 48 (05) : 313 - 322
  • [23] Attenuation correction for pre-clinical PET images using a small animal CT scanner
    D'Ambrosio, D.
    Spinelli, A. E.
    Boschi, S.
    Quarta, C.
    Franchi, R.
    Pagotto, U.
    Marengo, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S227 - S228
  • [24] 137Cs transmission imaging and segmented attenuation corrections in a small animal PET scanner
    Nai Y.-H.
    Ose T.
    Shidahara M.
    Watabe H.
    Radiological Physics and Technology, 2017, 10 (3) : 321 - 330
  • [25] Evaluation of Scatter Fraction and Noise Equivalent Count Rate Performance of the microPET F-220 Scanner Integrated with the Micro Insert Device
    Wu, Chih-Chieh
    Wu, Heyu
    Tai, Yuan-Chuan
    Lin, Kang-Ping
    Liu, Ren-Shyan
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2010, 30 (04) : 261 - 266
  • [26] Attenuation correction for freely moving small animal brain PET studies based on a virtual scanner geometry
    Angelis, G. I.
    Kyme, A. Z.
    Ryder, W. J.
    Fulton, R. R.
    Meikle, S. R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (19): : 5651 - 5666
  • [27] Improved attenuation correction for freely moving animal brain PET studies using a virtual scanner geometry
    Angelis, Georgios I.
    Ryder, William J.
    Kyme, Andre Z.
    Fulton, Roger R.
    Meikle, Steven R.
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [28] Evaluation of attenuation correction requirement in small animal PET and SPECT imaging
    Konik, Arda
    Madsen, Mark
    Sunderland, John
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [29] Quantification accuracy and partial volume effect in dependence of the attenuation correction of a state-of-the-art small animal PET scanner
    Mannheim, Julia G.
    Judenhofer, Martin S.
    Schmid, Andreas
    Tillmanns, Julia
    Stiller, Detlef
    Sossi, Vesna
    Pichler, Bernd J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (12): : 3981 - 3993
  • [30] QUANTITATIVE SPECT BY ATTENUATION CORRECTION OF THE PROJECTION SET USING TRANSMISSION DATA - EVALUATION OF A METHOD
    ALMQUIST, H
    PALMER, J
    LJUNGBERG, M
    WOLLMER, P
    STRAND, SE
    JONSON, B
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1990, 16 (8-10): : 587 - 594