Attenuation correction for the NIH ATLAS small animal PET scanner

被引:0
|
作者
Yao, RT [1 ]
Seidel, R [1 ]
Liow, JS [1 ]
Green, MV [1 ]
机构
[1] SUNY Buffalo, Dept Nucl Med, Buffalo, NY 14214 USA
关键词
D O I
10.1109/NSSMIC.2003.1352353
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We evaluated two methods of attenuation correction for the NIH ATLAS small animal PET scanner: 1) a CT-based method that derives 511 keV attenuation coefficients (mu) by extrapolation from spatially registered CT images; and 2) an analytic method based on the body outline of emission images and an empirical mu. A specially fabricated attenuation calibration phantom with cylindrical inserts that mimic different body tissues was used to derive the relationship to convert CT values to mu for PET. The methods were applied to three test data sets: 1) a uniform cylinder phantom, 2) the attenuation calibration phantom and 3) a mouse injected with [F-18] FDG. The CT-based attenuation correction factors were larger in non-uniform regions of the imaging subject, e.g. mouse head, than the analytic method. The two methods had similar correction factors for regions with uniform density and detectable emission source distributions.
引用
收藏
页码:2283 / 2287
页数:5
相关论文
共 50 条
  • [21] System Integration of the LabPET™ Small Animal PET Scanner
    Tetrault, M. -A.
    Viscogliosi, N.
    Riendeau, J.
    Belanger, F.
    Michaud, J. B.
    Semmaoui, H.
    Berard, P.
    Lemieux, F.
    Arpin, L.
    Cadorette, J.
    Pepin, C. M.
    Robert, G.
    Lepage, M. D.
    Lecomte, R.
    Fontaine, R.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1880 - 1884
  • [22] Design of a small animal MR compatible PET scanner
    Slates, R
    Cherry, S
    Boutefnouchet, A
    Shao, YP
    Dahlbom, M
    Farahani, K
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) : 565 - 570
  • [23] Design of a small animal MR compatible PET scanner
    UCLA Sch of Medicine, Los Angeles, United States
    IEEE Trans Nucl Sci, 3 II (565-570):
  • [24] System Architecture of the LabPET Small Animal PET Scanner
    Tetrault, Mare-Andre
    Viscogliosi, Nicolas
    Riendeau, Joel
    Belanger, Francois
    Michaud, Jean-Baptiste
    Semmaoui, Hicham
    Berard, Philippe
    Lemieux, Francois
    Arpin, Louis
    Bergeron, Melanie
    Cadorette, Jules
    Pepin, Catherine M.
    Robert, Ghislain
    Lepage, Martin D.
    Lecomte, Roger
    Fontaine, Rejean
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (05) : 2546 - 2550
  • [25] Design of a small animal MR compatible PET scanner
    Slates, Randal
    Cherry, Simon
    Boutefnouchet, Abdel
    Shao, Yiping
    Dahlbom, Magnus
    Farahani, Keyvan
    IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 2 : 1268 - 1273
  • [26] Addressing PET Attenuation Correction Challenges for the ACR Accreditation of a Simultaneous PET/MR Scanner
    Kulkarni, H.
    Samuels, A.
    Faasse, T.
    Sridhar, V.
    Hu, L.
    Botti, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S693 - S693
  • [27] Attenuation correction for a combined 3D PET/CT scanner
    Kinahan, PE
    Townsend, DW
    Beyer, T
    Sashin, D
    MEDICAL PHYSICS, 1998, 25 (10) : 2046 - 2053
  • [28] MR-based attenuation correction for cardiac FDG PET on a hybrid PET/MRI scanner: comparison with standard CT attenuation correction
    Jan Vontobel
    Riccardo Liga
    Mathias Possner
    Olivier F. Clerc
    Fran Mikulicic
    Patrick Veit-Haibach
    Edwin E. G. W. ter Voert
    Tobias A. Fuchs
    Julia Stehli
    Aju P. Pazhenkottil
    Dominik C. Benz
    Christoph Gräni
    Oliver Gaemperli
    Bernhard Herzog
    Ronny R. Buechel
    Philipp A. Kaufmann
    European Journal of Nuclear Medicine and Molecular Imaging, 2015, 42 : 1574 - 1580
  • [29] MR-based attenuation correction for cardiac FDG PET on a hybrid PET/MRI scanner: comparison with standard CT attenuation correction
    Vontobel, Jan
    Liga, Riccardo
    Possner, Mathias
    Clerc, Olivier F.
    Mikulicic, Fran
    Veit-Haibach, Patrick
    ter Voert, Edwin E. G. W.
    Fuchs, Tobias A.
    Stehli, Julia
    Pazhenkottil, Aju P.
    Benz, Dominik C.
    Graeni, Christoph
    Gaemperli, Oliver
    Herzog, Bernhard
    Buechel, Ronny R.
    Kaufmann, Philipp A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (10) : 1574 - 1580
  • [30] Predicting Small Lesion Detectability for a Small Animal TOF PET Scanner
    Yussefian, Nikta Zarif
    Gaudin, Emilie
    Lecomte, Roger
    Fontaine, Rejean
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2022, 6 (05) : 601 - 608