Attenuation correction for the NIH ATLAS small animal PET scanner

被引:0
|
作者
Yao, RT [1 ]
Seidel, R [1 ]
Liow, JS [1 ]
Green, MV [1 ]
机构
[1] SUNY Buffalo, Dept Nucl Med, Buffalo, NY 14214 USA
关键词
D O I
10.1109/NSSMIC.2003.1352353
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We evaluated two methods of attenuation correction for the NIH ATLAS small animal PET scanner: 1) a CT-based method that derives 511 keV attenuation coefficients (mu) by extrapolation from spatially registered CT images; and 2) an analytic method based on the body outline of emission images and an empirical mu. A specially fabricated attenuation calibration phantom with cylindrical inserts that mimic different body tissues was used to derive the relationship to convert CT values to mu for PET. The methods were applied to three test data sets: 1) a uniform cylinder phantom, 2) the attenuation calibration phantom and 3) a mouse injected with [F-18] FDG. The CT-based attenuation correction factors were larger in non-uniform regions of the imaging subject, e.g. mouse head, than the analytic method. The two methods had similar correction factors for regions with uniform density and detectable emission source distributions.
引用
收藏
页码:2283 / 2287
页数:5
相关论文
共 50 条
  • [31] A method for estimating the attenuation correction for the MR hardware of an MR/PET scanner
    Eldib, Mootaz
    Faul, David
    Ladebeck, Ralf
    Pawlak, John
    Doshi, Niraj
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [32] Multi-Atlas-Based Attenuation Correction for Brain 18F-FDG PET Imaging Using a Time-of-Flight PET/MR Scanner: Comparison with Clinical Single-Atlas- and CT-Based Attenuation Correction
    Sekine, Tetsuro
    Burgos, Ninon
    Warnock, Geoffrey
    Huellner, Martin
    Buck, Alfred
    ter Voert, Edwin E. G. W.
    Cardoso, M. Jorge
    Hutton, Brian F.
    Ourselin, Sebastien
    Veit-Haibach, Patrick
    Delso, Gaspar
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (08) : 1258 - 1264
  • [33] Evaluation of Attenuation and Scatter Correction Requirements as a Function of Object Size in PET Small Animal Imaging
    Konik, A.
    Koesters, T.
    Madsen, M. T.
    Sunderland, J. J.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3458 - 3465
  • [34] Evaluation of Attenuation and Scatter Correction Requirements as a Function of Object Size in Small Animal PET Imaging
    Konik, A.
    Koesters, T.
    Madsen, M. T.
    Sunderland, J. J.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (05) : 2308 - 2314
  • [35] Performance evaluation of the Philips MOSAIC small animal PET scanner
    Huisman, Marc C.
    Reder, Sybille
    Weber, Axel W.
    Ziegler, Sibylle I.
    Schwaiger, Markus
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (04) : 532 - 540
  • [36] Temperature dependence of the LabPET small-animal PET scanner
    Keereman, Vincent
    Van Holen, Roel
    Vanhove, Christian
    Vandenberghe, Stefaan
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [37] Analog processing board for the MiCES small animal PET scanner
    Park, B
    Lewellen, TK
    Miyaoka, RS
    Janes, M
    Kinahan, P
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3920 - 3923
  • [38] System integration of the MiCES small animal PET scanner.
    Lewellen, TK
    Janes, M
    Miyaoka, RS
    Gillespie, SB
    Park, B
    Lee, KS
    Kinahan, P
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3316 - 3320
  • [39] Development of a small animal PET scanner using DOI detectors
    Yamada, R.
    Watanabe, M.
    Omura, T.
    Sato, N.
    Shimizu, K.
    Takahashi, M.
    Ote, K.
    Katabe, A.
    Moriya, T.
    Sakai, K.
    Yamashita, T.
    Tanaka, E.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) : 906 - 911
  • [40] A small animal PET scanner with millimeter spatial resolution.
    Del Guerra, A
    Di Domenico, G
    Scandola, M
    Zavattini, G
    Giganti, M
    Uccelli, L
    Piffanelli, A
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 133P - 133P