Comparison of three methods of measuring corneal thickness and anterior chamber depth

被引:207
|
作者
Buehl, W
Stojanac, D
Sacu, S
Drexler, W
Findl, O
机构
[1] Med Univ Vienna, Dept Ophthalmol, A-1090 Vienna, Austria
[2] Med Univ Vienna, Dept Med Phys, Vienna, Austria
关键词
D O I
10.1016/j.ajo.2005.08.048
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare three different methods of measuring corneal thickness (CT) and anterior chamber depth (ACD). DESIGN: Prospective clinical trial (Medical University of Vienna, Austria). METHODS: Central CT (CCT), CT at four peripheral points, and central ACD were measured in 88 eyes of 44 healthy subjects with the Pentacam (rotating Scheimpflug camera; Oculus, Wetzlar, Germany), Orbscan I (scanning-slit topography system; Orbtek Inc, Salt Lake City, Utah, USA), and AC-Master (partial coherence interferome try; Zeiss Meditec, Jena, Germany), and the results were compared. RESULTS: The upper (lower) limits of agreement for CT measurements were 7.9 (-22.2) mu m between AC- Master and Pentacam, 17.6 (-32.5) mu m between AC- Master and Orbscan, and 25.2 (-25.9) mu m between Pentacam and Orbscan. Correlation was high between all three methods (r = 0.94 to 0.97). The upper and lower limits of agreement for ACD were 0.174 (-0.251) mm between AC-Master and Pentacam, 0.406 (-0.004) mm between AC-Master and Orbscan, and 0.384 (0.095) mm between Pentacam and Orbscan. Correlation was high between the three methods (r = 0.96 between Orbscan and Pentacam; others 0.92). Correlation was lower for the CT measurements at the four peripheral points. CONCLUSIONS: The CCT and ACD values obtained by Pentacam, Orbscan, and AC-Master measurements correlated well and showed few outliers. The two new systems (Pentacam, AC,Master) provide a reliable, easy-to-use, noncontact method of measuring CCT and ACD. Larger differences occurred only when measuring peripheral CT values, especially between AC,Master and the other two methods.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 50 条
  • [21] Comparison of Corneal Diameter and Anterior Chamber Depth Measurements Using 4 Different Devices
    Shajari, Mehdi
    Lehmann, Ulrike C.
    Kohnen, Thomas
    CORNEA, 2016, 35 (06) : 838 - 842
  • [22] Comparison of Central Corneal Thickness and Anterior Chamber Depth Measured Using LenStar LS900, Pentacam, and Visante AS-OCT
    O'Donnell, Clare
    Hartwig, Andreas
    Radhakrishnan, Hema
    CORNEA, 2012, 31 (09) : 983 - 988
  • [23] Evaluation of biometric methods for measuring the anterior chamber depth in the non-contact mode
    B. Meinhardt
    O. Stachs
    J. Stave
    R. Beck
    R. Guthoff
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2006, 244 : 559 - 564
  • [24] Evaluation of biometric methods for measuring the anterior chamber depth in the non-contact mode
    Meinhardt, B
    Stachs, O
    Stave, J
    Beck, R
    Guthoff, R
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 244 (05) : 559 - 564
  • [25] Measuring anterior chamber depth with the Orbscan Topography System
    Auffarth, GU
    Tetz, MR
    Biazid, Y
    Volcker, HE
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (09): : 1351 - 1355
  • [26] Changes in the anterior and posterior radii of the corneal curvature and anterior chamber depth by orthokeratology
    Tsukiyama, Junko
    Miyamoto, Yuko
    Higaki, Shiro
    Fukuda, Masahiko
    Shimomura, Yoshikazu
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2008, 34 (01): : 17 - 20
  • [27] Comparison of Keratometry, Central Corneal Thickness, and Anterior Chamber Depth Results Measured With Nidek-AL Scan Biometry and Sirius Topography Devices
    Bayramoglu, Sadik Etka
    Sayin, Nihat
    Ekinci, Dilbade Yildiz
    Erdogan, Mehmet
    ISTANBUL MEDICAL JOURNAL, 2018, 19 (02): : 158 - 161
  • [28] Correlation of corneal thickness, endothelial cell density and anterior chamber depth with ocular surface temperature in normal subjects
    Pattmoeller, Johanna
    Wang, Jiong
    Zemova, Elena
    Seitz, Berthold
    Eppig, Timo
    Langenbucher, Achim
    Szentmary, Nora
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2015, 25 (03): : 243 - 250
  • [29] Central Corneal Thickness, Anterior Chamber Depth, and Pupil Diameter Measurements Using Visante OCT, Orbscan, and Pentacam
    Yazici, Ahmet Taylan
    Bozkurt, Ercument
    Alagoz, Cengiz
    Alagoz, Nese
    Pekel, Gokhan
    Kaya, Vedat
    Yilmaz, Omer Faruk
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (02) : 127 - 133
  • [30] Body mass index, peripheral corneal thickness and anterior chamber depth in young European adults - A pilot study
    Jonuscheit, Sven
    Doughty, Michael
    Martin, Raul
    San Cristobal, Ana del Rio
    Mackintosh, Lisa
    MacTaggart, David
    Hiscock, Michael
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)