Comparison of three methods of measuring corneal thickness and anterior chamber depth

被引:207
|
作者
Buehl, W
Stojanac, D
Sacu, S
Drexler, W
Findl, O
机构
[1] Med Univ Vienna, Dept Ophthalmol, A-1090 Vienna, Austria
[2] Med Univ Vienna, Dept Med Phys, Vienna, Austria
关键词
D O I
10.1016/j.ajo.2005.08.048
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare three different methods of measuring corneal thickness (CT) and anterior chamber depth (ACD). DESIGN: Prospective clinical trial (Medical University of Vienna, Austria). METHODS: Central CT (CCT), CT at four peripheral points, and central ACD were measured in 88 eyes of 44 healthy subjects with the Pentacam (rotating Scheimpflug camera; Oculus, Wetzlar, Germany), Orbscan I (scanning-slit topography system; Orbtek Inc, Salt Lake City, Utah, USA), and AC-Master (partial coherence interferome try; Zeiss Meditec, Jena, Germany), and the results were compared. RESULTS: The upper (lower) limits of agreement for CT measurements were 7.9 (-22.2) mu m between AC- Master and Pentacam, 17.6 (-32.5) mu m between AC- Master and Orbscan, and 25.2 (-25.9) mu m between Pentacam and Orbscan. Correlation was high between all three methods (r = 0.94 to 0.97). The upper and lower limits of agreement for ACD were 0.174 (-0.251) mm between AC-Master and Pentacam, 0.406 (-0.004) mm between AC-Master and Orbscan, and 0.384 (0.095) mm between Pentacam and Orbscan. Correlation was high between the three methods (r = 0.96 between Orbscan and Pentacam; others 0.92). Correlation was lower for the CT measurements at the four peripheral points. CONCLUSIONS: The CCT and ACD values obtained by Pentacam, Orbscan, and AC-Master measurements correlated well and showed few outliers. The two new systems (Pentacam, AC,Master) provide a reliable, easy-to-use, noncontact method of measuring CCT and ACD. Larger differences occurred only when measuring peripheral CT values, especially between AC,Master and the other two methods.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 50 条
  • [41] Lens-thickness correlation with pseudophakic anterior chamber depth Reply
    Shammas, H. John
    Shammas, Maya C.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (04): : 646 - 647
  • [42] Comparison of anterior chamber depth measurements using the IOLMaster, scanning peripheral anterior chamber depth analyser, and anterior segment optical coherence tomography
    Lavanya, Raghavan
    Teo, Livia
    Friedman, David S.
    Aung, Han T.
    Baskaran, Mani
    Gao, Hong
    Alfred, Tamuno
    Seah, Steve K.
    Kashiwagi, Kenji
    Foster, Paul J.
    Aung, Tin
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (08) : 1023 - 1026
  • [43] A COMPARISON OF THICKNESS-MEASURING METHODS
    LOUIE, M
    CHRISTY, R
    THIN SOLID FILMS, 1987, 154 (1-2) : 291 - 299
  • [44] COMPARISON OF 3 METHODS FOR THE MEASUREMENT OF CORNEAL THICKNESS
    AZEN, SP
    BURG, KA
    SMITH, RE
    MAGUEN, E
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1979, 18 (05) : 535 - 538
  • [45] The distribution of axial length, anterior chamber depth, lens thickness, and vitreous chamber depth in an adult population of Shahroud, Iran
    Hashemi, Hassan
    Khabazkhoob, Mehdi
    Miraftab, Mohammad
    Emamian, Mohammad Hassan
    Shariati, Mohammad
    Abdolahinia, Tahereh
    Fotouhi, Akbar
    BMC OPHTHALMOLOGY, 2012, 12
  • [46] EVALUATION OF 3 METHODS OF RECORDING ANTERIOR CHAMBER DEPTH OF EYE
    BLEEKER, GM
    ARCHIVES OF OPHTHALMOLOGY, 1961, 65 (03) : 369 - &
  • [47] The distribution of axial length, anterior chamber depth, lens thickness, and vitreous chamber depth in an adult population of Shahroud, Iran
    Hassan Hashemi
    Mehdi Khabazkhoob
    Mohammad Miraftab
    Mohammad Hassan Emamian
    Mohammad Shariati
    Tahereh Abdolahinia
    Akbar Fotouhi
    BMC Ophthalmology, 12
  • [49] Corneal radii and anterior chamber depth measurements using the IOLMaster versus the Pentacam
    Reuland, Mirjarn S.
    Reuland, Andreas J.
    Nishi, Yutaro
    Auffarth, Gerd U.
    JOURNAL OF REFRACTIVE SURGERY, 2007, 23 (04) : 368 - 373
  • [50] CORNEAL THICKNESS AFTER CATARACT-EXTRACTION WITH AIR IN ANTERIOR-CHAMBER
    NORN, MS
    ACTA OPHTHALMOLOGICA, 1975, 53 (05): : 747 - 750