Corneal radii and anterior chamber depth measurements using the IOLMaster versus the Pentacam

被引:0
|
作者
Reuland, Mirjarn S. [1 ]
Reuland, Andreas J. [1 ]
Nishi, Yutaro [1 ]
Auffarth, Gerd U. [1 ]
机构
[1] Univ Heidelberg, Dept Ophthalmol, Heidelberg Intraocular Lens & Refract Surg Res Gr, D-69120 Heidelberg, Germany
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: Corneal radii (R1, R2) and anterior chamber depth are important parameters for biometry and refractive surgery. This study aimed to investigate whether the IOLMaster, a biometric device, and the Pentacam, a rotating Scheimpflug camera, provide comparable results. METHODS: In this prospective study, corneal radii and anterior chamber depth were analyzed in 82 eyes of 41 phakic patients (median age 72 years) using the IOLMaster and Pentacam. Normal distribution was confirmed using the Kolmogorov-Smimov test. A paired t test was used for statistical. analysis. RESULTS: No statistically significant difference was noted for R2 using the Pentacam versus the IOLMaster (P=.40). There was a small statistical difference of 0.03 mm (P <.01) for R1 (corresponding to 0.08 diopters [D]). The IOLMaster measured a mean R1 of 7.87 mm and R2 of 7.67 mm. The Pentacam measured mean R1 of 7.90 mm and R2 of 7.69 mm. For anterior chamber depth values, a small statistically significant difference of 0.05 mm (P <.001) was found (corresponding to 0.01 D). Mean anterior chamber depth measured from the epithelium was 3.20 mm for the IOLMaster and 3.25 mm for the Pentacam. The Bland-Altman plot showed no distorting trends for either variable. CONCLUSIONS: Keratometry and anterior chamber depth were comparable for the two devices. If the axial length is known, the Pentacam can be used as a biometric device.
引用
收藏
页码:368 / 373
页数:6
相关论文
共 50 条
  • [1] Comparison of Anterior Chamber Depth Measurements Conducted With Pentacam HR® and IOLMaster®
    Nemeth, Gabor
    Hassan, Ziad
    Modis, Laszlo, Jr.
    Szalai, Eszter
    Katona, Kristof
    Berta, Andras
    OPHTHALMIC SURGERY LASERS & IMAGING, 2011, 42 (02) : 144 - 147
  • [2] Agreement of phakic and pseudophakic anterior chamber depth measurements in IOLMaster and Pentacam
    Hamoudi, Hassan
    Christensen, Ulrik Correll
    la Cour, Morten
    ACTA OPHTHALMOLOGICA, 2018, 96 (03) : E403 - E403
  • [3] Comparability and intra-/interobserver reliability of anterior chamber depth measurements with the Pentacam and IOLMaster
    Savant, Vijay
    Chavan, Randhir
    Pushpoth, Sreekumari
    Ilango, B.
    JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (06) : 615 - 618
  • [4] Comparison of anterior chamber depth measurements taken with the Pentacam, Orbscan IIz and IOLMaster in myopic and emmetropic eyes
    Utine, Canan Asli
    Altin, Feyza
    Cakir, Hanefi
    Perente, Irfan
    ACTA OPHTHALMOLOGICA, 2009, 87 (04) : 386 - 391
  • [5] Comparison of anterior chamber depth measurements using Orbscan II and IOLMaster
    Frisch, I. B.
    Rabsilber, T. M.
    Becker, K. A.
    Reuland, A. J.
    Auffarth, G. U.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2007, 17 (03) : 327 - 331
  • [6] Agreement of Corneal Diameter and Anterior Chamber Depth Measurements with the IOLMaster 500 and the IOLMaster 700 Optical Biometers in Myopic Eyes
    Tana-Rivero, Pedro
    Tello-Elordi, Cristina
    Orts-Vila, Paz
    Tana-Sanz, Pedro
    Tana-Sanz, Santiago
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 1245 - 1253
  • [7] Central Corneal Thickness, Anterior Chamber Depth, and Pupil Diameter Measurements Using Visante OCT, Orbscan, and Pentacam
    Yazici, Ahmet Taylan
    Bozkurt, Ercument
    Alagoz, Cengiz
    Alagoz, Nese
    Pekel, Gokhan
    Kaya, Vedat
    Yilmaz, Omer Faruk
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (02) : 127 - 133
  • [8] Anterior chamber depth measurements in phakic and pseudophakic eyes: Pentacam versus ultrasound device
    Nemeth, Gabor
    Vajas, Attila
    Kolozsvari, Bence
    Berta, Andras
    Modis, Laszlo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (08): : 1331 - 1335
  • [9] Comparison of anterior chamber depth measurements using the IOLMaster, scanning peripheral anterior chamber depth analyser, and anterior segment optical coherence tomography
    Lavanya, Raghavan
    Teo, Livia
    Friedman, David S.
    Aung, Han T.
    Baskaran, Mani
    Gao, Hong
    Alfred, Tamuno
    Seah, Steve K.
    Kashiwagi, Kenji
    Foster, Paul J.
    Aung, Tin
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (08) : 1023 - 1026
  • [10] Validity and Repeatability of Anterior Chamber Depth Measurements With Pentacam and Orbscan
    Lackner, Birgit
    Schmidinger, Gerald
    Skorpik, Christian
    OPTOMETRY AND VISION SCIENCE, 2005, 82 (09) : 858 - 861