Comparison of three methods of measuring corneal thickness and anterior chamber depth

被引:207
|
作者
Buehl, W
Stojanac, D
Sacu, S
Drexler, W
Findl, O
机构
[1] Med Univ Vienna, Dept Ophthalmol, A-1090 Vienna, Austria
[2] Med Univ Vienna, Dept Med Phys, Vienna, Austria
关键词
D O I
10.1016/j.ajo.2005.08.048
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare three different methods of measuring corneal thickness (CT) and anterior chamber depth (ACD). DESIGN: Prospective clinical trial (Medical University of Vienna, Austria). METHODS: Central CT (CCT), CT at four peripheral points, and central ACD were measured in 88 eyes of 44 healthy subjects with the Pentacam (rotating Scheimpflug camera; Oculus, Wetzlar, Germany), Orbscan I (scanning-slit topography system; Orbtek Inc, Salt Lake City, Utah, USA), and AC-Master (partial coherence interferome try; Zeiss Meditec, Jena, Germany), and the results were compared. RESULTS: The upper (lower) limits of agreement for CT measurements were 7.9 (-22.2) mu m between AC- Master and Pentacam, 17.6 (-32.5) mu m between AC- Master and Orbscan, and 25.2 (-25.9) mu m between Pentacam and Orbscan. Correlation was high between all three methods (r = 0.94 to 0.97). The upper and lower limits of agreement for ACD were 0.174 (-0.251) mm between AC-Master and Pentacam, 0.406 (-0.004) mm between AC-Master and Orbscan, and 0.384 (0.095) mm between Pentacam and Orbscan. Correlation was high between the three methods (r = 0.96 between Orbscan and Pentacam; others 0.92). Correlation was lower for the CT measurements at the four peripheral points. CONCLUSIONS: The CCT and ACD values obtained by Pentacam, Orbscan, and AC-Master measurements correlated well and showed few outliers. The two new systems (Pentacam, AC,Master) provide a reliable, easy-to-use, noncontact method of measuring CCT and ACD. Larger differences occurred only when measuring peripheral CT values, especially between AC,Master and the other two methods.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 50 条
  • [31] Corneal thickness and anterior chamber depth by Orbscan in normal and primary open-angle glaucoma patients in Korea
    Kim, Na Rae
    Kim, Chan Yun
    Oh, Jung Hyub
    Lee, Eun Suk
    JOURNAL OF GLAUCOMA, 2008, 17 (06) : 465 - 469
  • [32] Comparison between newly developed scanning peripheral anterior chamber depth analyzer and conventional methods of evaluating anterior chamber configuration
    Kashiwagi, Kenji
    Tsumura, Toyoaki
    Tsukahara, Shigeo
    JOURNAL OF GLAUCOMA, 2006, 15 (05) : 380 - 387
  • [33] Lens-thickness correlation with pseudophakic anterior chamber depth
    Galvis, Virgilio
    Tello, Alejandro
    Frederick, Gabriel A.
    Serrano, Andres
    Camacho, Paul A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (04): : 645 - 646
  • [34] Comparison of different devices for measuring corneal thickness
    Mohammadpour, M
    JOURNAL OF REFRACTIVE SURGERY, 2005, 21 (05) : S666 - S666
  • [35] Reliability of the Effect of Artificial Anterior Chamber Pressure and Corneal Drying on Corneal Graft Thickness
    Romano, Vito
    Steger, Bernhard
    Chen, Jern Y.
    Hassaan, Sherif
    Batterbury, Mark
    Willoughby, Colin E.
    Ahmad, Sajjad
    Elsheikh, Ahmed
    Kaye, Stephen B.
    CORNEA, 2015, 34 (08) : 866 - 869
  • [36] Change in central corneal thickness, corneal endothelial cell density, anterior chamber depth and axial length after repair of rhegmatogenous retinal detachment
    Mukhtar, Ahsan
    Mehboob, Mohammad Asim
    Babar, Zaheer Uddin
    Ishaq, Mazhar
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2017, 33 (06) : 1412 - 1417
  • [37] Comparison of three methods of intraocular pressure measurement and their relation to central corneal thickness
    F Carbonaro
    T Andrew
    D A Mackey
    T D Spector
    C J Hammond
    Eye, 2010, 24 : 1165 - 1170
  • [38] Comparison of three methods of intraocular pressure measurement and their relation to central corneal thickness
    Carbonaro, F.
    Andrew, T.
    Mackey, D. A.
    Spector, T. D.
    Hammond, C. J.
    EYE, 2010, 24 (07) : 1165 - 1170
  • [39] Anterior chamber depth, lens thickness and intraocular lens calculation formula accuracy: nine formulas comparison
    Hipolito-Fernandes, Diogo
    Luis, Maria Elisa
    Serras-Pereira, Rita
    Gil, Pedro
    Maduro, Vitor
    Feijao, Joao
    Alves, Nuno
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2022, 106 (03) : 349 - 355
  • [40] DEPTH OF ANTERIOR-CHAMBER AND LENS THICKNESS IN SENILE CATARACTOUS EYES
    OBAZAWA, H
    MIKUNI, I
    FUJIWARA, T
    KAWAHARA, T
    FOLIA OPHTHALMOLOGICA JAPONICA, 1978, 29 (06): : 873 - 880