Reliability of the Effect of Artificial Anterior Chamber Pressure and Corneal Drying on Corneal Graft Thickness

被引:16
|
作者
Romano, Vito [1 ]
Steger, Bernhard [2 ]
Chen, Jern Y. [3 ]
Hassaan, Sherif [3 ]
Batterbury, Mark [1 ]
Willoughby, Colin E. [1 ,2 ]
Ahmad, Sajjad [1 ,2 ]
Elsheikh, Ahmed [3 ]
Kaye, Stephen B. [1 ,2 ]
机构
[1] Royal Liverpool Univ Hosp, St Pauls Eye Unit, Dept Corneal & External Eye Dis, Liverpool L7 8XP, Merseyside, England
[2] Univ Liverpool, Dept Eye & Vision Sci, Liverpool L69 3BX, Merseyside, England
[3] Univ Liverpool, Sch Engn, Liverpool L69 3BX, Merseyside, England
关键词
corneal thickness; endothelial graft preparation; DSAEK; endothelial keratoplasty; AUTOMATED ENDOTHELIAL KERATOPLASTY; POSTERIOR LAMELLAR KERATOPLASTY; DMEK;
D O I
10.1097/ICO.0000000000000451
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the effect of artificial anterior chamber (AAC) pressure and corneal drying on the graft thickness in preparation for Descemet stripping automated endothelial keratoplasty. Methods: Twenty-seven corneoscleral discs were placed in an AAC. The AAC pressure (15, 45, 92, 109, and 198 mm Hg) was controlled using the height of an infusion bottle and a roller clamp. The endothelium was removed in 1 subgroup. Corneas were exposed to room air or repeatedly dried using cellulose spears. Central corneal thickness was measured every 90 seconds for the first 15 minutes and again at 20 minutes using an ultrasound pachymeter (SP-100, Tomey). Results: There was a significant linear relationship between the corneal thickness and both AAC pressure and corneal drying. Very high coefficients of determination and narrow 95% confidence intervals were present, in particular for high pressures and drying. The rate of thinning increased with increasing pressure and drying to 1.6% per minute. At the maximum rate of thinning, a 10% reduction in corneal thickness occurred in 6 minutes or 100 mu m in 8.8 minutes. Removal of the corneal endothelium reduced the rate of thinning to 0.3% per minute (R-2 = 0.72). Conclusions: Increasing AAC pressure and corneal drying reduced the graft thickness at a very predictable rate. Adequate corneal thinning can be achieved by increasing the pressure in the AAC by closing the clamp followed by removal of the residual corneal epithelium and repeated drying with a cellulose spear for 5 to 10 minutes, depending on the initial corneal thickness. This method is simple and is both suitable for use in the eye bank and by the surgeon.
引用
收藏
页码:866 / 869
页数:4
相关论文
共 50 条
  • [1] The effect of anterior chamber pressure and corneal drying on corneal thickness in preparation for descemet stripping endothelial keratoplasty (DSAEK)
    Steger, Bernhard
    Romano, Vito
    Hassaan, Sherif
    Batterbury, Mark
    Ahmad, Sajjad
    Willoughby, Colin E.
    Elsheikh, Ahmed
    Chen, Jern Yee
    Kaye, Stephen B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [2] THE EFFECT OF CORNEAL DRYING ON CENTRAL CORNEAL THICKNESS
    V.Dayanir
    R.Sakarya
    A.Topaloglu
    E.Kir
    T.Aktunc
    S.B.Ozkan
    国际眼科杂志, 2003, (01) : 73 - 74
  • [3] Effect of corneal drying on central corneal thickness
    Dayanir, V
    Sakarya, R
    Özcura, F
    Kir, E
    Aktunç, T
    Özkan, BS
    Okyay, P
    JOURNAL OF GLAUCOMA, 2004, 13 (01) : 6 - 8
  • [4] The effect of scleral buckling surgery on corneal astigmatism, corneal thickness, and anterior chamber depth
    Cetin, E
    Ozbek, Z
    Saatci, O
    Durak, I
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (05) : 494 - 499
  • [5] Artificial Anterior Chamber Pressure and Corneal Thinning Rate in UT-DSAEK
    Parekh, Mohit
    Ruzza, Alessandro
    Borroni, Davide
    Kaye, Stephen B.
    Romano, Vito
    CORNEA, 2018, 37 (02) : E5 - E5
  • [6] Effect of Anterior Chamber Air on Central Corneal Thickness in Human Donor Eyes
    Huertas-Bello, Marcela
    Seery, Christopher W.
    Sem, Karen
    Fout, Elizabeth
    Triglia, Concetta
    Eghrari, Allen O.
    Koo, Ellen H.
    CORNEA, 2024, 43 (11) : 1355 - 1360
  • [9] Corneal lenticule harvest using a microkeratome and an artificial anterior chamber system at high intrachamber pressure
    Li, L
    Behrens, A
    Sweet, PM
    Osann, KE
    Chuck, RS
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (05): : 860 - 865
  • [10] Comparison of three methods of measuring corneal thickness and anterior chamber depth
    Buehl, W
    Stojanac, D
    Sacu, S
    Drexler, W
    Findl, O
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (01) : 7 - 12