Reliability of the Effect of Artificial Anterior Chamber Pressure and Corneal Drying on Corneal Graft Thickness

被引:16
|
作者
Romano, Vito [1 ]
Steger, Bernhard [2 ]
Chen, Jern Y. [3 ]
Hassaan, Sherif [3 ]
Batterbury, Mark [1 ]
Willoughby, Colin E. [1 ,2 ]
Ahmad, Sajjad [1 ,2 ]
Elsheikh, Ahmed [3 ]
Kaye, Stephen B. [1 ,2 ]
机构
[1] Royal Liverpool Univ Hosp, St Pauls Eye Unit, Dept Corneal & External Eye Dis, Liverpool L7 8XP, Merseyside, England
[2] Univ Liverpool, Dept Eye & Vision Sci, Liverpool L69 3BX, Merseyside, England
[3] Univ Liverpool, Sch Engn, Liverpool L69 3BX, Merseyside, England
关键词
corneal thickness; endothelial graft preparation; DSAEK; endothelial keratoplasty; AUTOMATED ENDOTHELIAL KERATOPLASTY; POSTERIOR LAMELLAR KERATOPLASTY; DMEK;
D O I
10.1097/ICO.0000000000000451
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the effect of artificial anterior chamber (AAC) pressure and corneal drying on the graft thickness in preparation for Descemet stripping automated endothelial keratoplasty. Methods: Twenty-seven corneoscleral discs were placed in an AAC. The AAC pressure (15, 45, 92, 109, and 198 mm Hg) was controlled using the height of an infusion bottle and a roller clamp. The endothelium was removed in 1 subgroup. Corneas were exposed to room air or repeatedly dried using cellulose spears. Central corneal thickness was measured every 90 seconds for the first 15 minutes and again at 20 minutes using an ultrasound pachymeter (SP-100, Tomey). Results: There was a significant linear relationship between the corneal thickness and both AAC pressure and corneal drying. Very high coefficients of determination and narrow 95% confidence intervals were present, in particular for high pressures and drying. The rate of thinning increased with increasing pressure and drying to 1.6% per minute. At the maximum rate of thinning, a 10% reduction in corneal thickness occurred in 6 minutes or 100 mu m in 8.8 minutes. Removal of the corneal endothelium reduced the rate of thinning to 0.3% per minute (R-2 = 0.72). Conclusions: Increasing AAC pressure and corneal drying reduced the graft thickness at a very predictable rate. Adequate corneal thinning can be achieved by increasing the pressure in the AAC by closing the clamp followed by removal of the residual corneal epithelium and repeated drying with a cellulose spear for 5 to 10 minutes, depending on the initial corneal thickness. This method is simple and is both suitable for use in the eye bank and by the surgeon.
引用
收藏
页码:866 / 869
页数:4
相关论文
共 50 条
  • [21] Central Corneal Thickness Correlates With Oxygen Levels in the Human Anterior Chamber Angle
    Yolcu, Umit
    Ilhan, Abdullah
    Gundogan, Fatih C.
    Erdem, Uzeyir
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 159 (03) : 610 - 610
  • [22] SILICONE OIL IN ANTERIOR CHAMBER OF EYE - EFFECT ON CORNEAL HYDRATION
    MARTOLA, EL
    DOHLMAN, CH
    ACTA OPHTHALMOLOGICA, 1963, 41 (01): : 75 - &
  • [23] Full-Thickness Compressive Corneal Sutures with Removal of Anterior Chamber Air Bubble in the Management of Acute Corneal Hydrops
    Ashena, Zahra
    Mukhija, Ritika
    Nanavaty, Mayank A.
    VISION, 2023, 7 (01)
  • [24] Quality of vision and graft thickness in deep anterior lamellar and penetrating corneal allografts
    Ardiomand, Navid
    Hau, Scott
    McAlister, James C.
    Bunce, Catey
    Galaretta, David
    Tuft, Stephen J.
    Larkin, Daniel F. P.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (02) : 228 - 235
  • [25] Corneal thickness and applanation pressure
    Naumann, GOH
    ARCHIVES OF OPHTHALMOLOGY, 1998, 116 (05) : 701 - 701
  • [26] Comparison of Central Corneal Thickness and Anterior Chamber Depth measured by Three Different Devices
    Shin, Minchul
    Chung, Se Yoon
    Lee, Hyo Kyung
    Hwang, Ho Sik
    Han, Kyung Eun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [27] Corneal thickness and anterior chamber depth of the normal adult horse as measured by ultrasound biomicroscopy
    Knickelbein, Kelly E.
    Lassaline, Mary E.
    Kim, Soohyun
    Scharbrough, Machal S.
    Thomasy, Sara M.
    VETERINARY OPHTHALMOLOGY, 2022, 25 : 17 - 24
  • [28] Quantitative changes in the corneal endothelium and central corneal thickness during anterior chamber inflammation: A systematic review and meta-analysis
    Mejia-Salgado, German
    Munoz-Vargas, Paula Tatiana
    Cifuentes-Gonzalez, Carlos
    Florez-Esparza, Gabriela
    Paquentin-Jimenez, Rebeca
    Castro-Monreal, Miguel Angel
    Medina-Galindo, Naomi
    Hernandez-Herrera, Gilma Norella
    Concha-del-Rio, Luz Elena
    de-la-Torre, Alejandra
    PLOS ONE, 2024, 19 (01):
  • [29] ANTERIOR-CHAMBER SCROLL AND CORNEAL EDEMA
    PERETZ, WL
    BLOOMFIELD, SE
    ANNALS OF OPHTHALMOLOGY, 1977, 9 (10): : 1315 - 1318
  • [30] Comparison of Anterior Chamber Depth and Central Corneal Thickness Measured Using Different Devices
    Jeung, Jae Gyun
    Gil, Tae Young
    Bae, Gi Hyun
    Shin, Seong Joo
    Chung, Sung Kun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (10): : 1570 - 1576