Correlation of corneal thickness, endothelial cell density and anterior chamber depth with ocular surface temperature in normal subjects

被引:11
|
作者
Pattmoeller, Johanna [1 ]
Wang, Jiong [1 ,2 ]
Zemova, Elena [1 ]
Seitz, Berthold [1 ]
Eppig, Timo
Langenbucher, Achim [3 ]
Szentmary, Nora [1 ]
机构
[1] Univ Saarland, Med Ctr, Dept Ophthalmol, D-66421 Homburg, Germany
[2] Wuhan Univ, Renmin Hosp, Dept Ophthalmol, Wuhan 430072, Peoples R China
[3] Univ Saarland, Expt Ophthalmol, D-66421 Homburg, Germany
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2015年 / 25卷 / 03期
关键词
Corneal surface thermography; noncontact measurement; temperature profile; temperature change; corneal thickness; anterior chamber depth; endothelial cell density; HEALTHY-SUBJECTS; TEAR FILM; DRY EYE; THERMOGRAPHY; ADULTS; BODY;
D O I
10.1016/j.zemedi.2014.09.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To analyze corneal surface temperature profile in a young and healthy study population and to determine the impact of corneal thickness (CT), anterior chamber depth (ACD), and endothelial cell density (ECD) on surface temperature. Methods: In this prospective, single-center study 61 healthy right eyes of 61 subjects without tear film pathologies (mean age 24.9 +/- 6.7 years) were recruited. Ocular surface temperature (OST) was measured with the Ocular Surface Thermographer TG-1000. From Pentacam HR CT and ACD, and from specular microscopy ECD and central corneal thickness (CCT) were acquired. From the raw measurement data (OST, CT and ACD) we extracted a) local OST the corneal center and 3 mm away from the center at the 3, 6, and 9 o'clock positions, and b) Zernike parameters Z1, Z2 and Z3 to evaluate the general temperature profile within a 6 mm circular area around the center Results: Overall, there was no correlation between OST and CT, ACD or ECD. Local OST did not correlate with CT at any measurement position. On average local OST was highest at measurement positions where CT was lowest, but without reaching statistical significance. Baseline OST was highest at thin corneal regions and temperature decay over time was smallest in those regions. Z1, Z2 and Z3 correlated well with CT Conclusions: In healthy subjects corneal thickness, endothelial cell density and anterior chamber depth have no effect on corneal surface temperature. The general temperature profile seems to be influenced by the corneal thickness profile effecting a higher temperature and lower decay at thinner corneal regions.
引用
收藏
页码:243 / 250
页数:8
相关论文
共 50 条
  • [1] Correlation between Corneal Endothelial Cell Density and Central Ocular Surface Temperature in Normal and Keratoconus Eyes
    Nemeth, Orsolya
    Langenbucher, Achim
    Eppig, Timo
    Lepper, Sabine
    Milioti, Georgia
    Abdin, Aladin
    Nagy, Zoltan Zsolt
    Seitz, Berthold
    Szentmary, Nora
    CURRENT EYE RESEARCH, 2021, 46 (04) : 445 - 451
  • [2] Change in central corneal thickness, corneal endothelial cell density, anterior chamber depth and axial length after repair of rhegmatogenous retinal detachment
    Mukhtar, Ahsan
    Mehboob, Mohammad Asim
    Babar, Zaheer Uddin
    Ishaq, Mazhar
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2017, 33 (06) : 1412 - 1417
  • [3] Effects of anterior chamber depth and axial length on corneal endothelial cell density after phacoemulsification
    Khalid, Muhammad
    Ameen, Sameer Shahid
    Ayub, Nauman
    Mehboob, Muhammad Asim
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2019, 35 (01) : 200 - 204
  • [4] Corneal thickness and anterior chamber depth of the normal adult horse as measured by ultrasound biomicroscopy
    Knickelbein, Kelly E.
    Lassaline, Mary E.
    Kim, Soohyun
    Scharbrough, Machal S.
    Thomasy, Sara M.
    VETERINARY OPHTHALMOLOGY, 2022, 25 : 17 - 24
  • [6] Axial length, anterior chamber depth, lens thickness and horizontal corneal diameter in normal children
    Costa, AMC
    Calixto, N
    Milhomens, EG
    Cronemberger, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [7] Correlation between Blood Flow and Temperature of the Ocular Anterior Segment in Normal Subjects
    Itokawa, Takashi
    Suzuki, Takashi
    Okajima, Yukinobu
    Kobayashi, Tatsuhiko
    Iwashita, Hiroko
    Gotoda, Satoshi
    Kakisu, Koji
    Tei, Yuto
    Hori, Yuichi
    DIAGNOSTICS, 2020, 10 (09)
  • [8] Comparison of three methods of measuring corneal thickness and anterior chamber depth
    Buehl, W
    Stojanac, D
    Sacu, S
    Drexler, W
    Findl, O
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (01) : 7 - 12
  • [9] The effect of scleral buckling surgery on corneal astigmatism, corneal thickness, and anterior chamber depth
    Cetin, E
    Ozbek, Z
    Saatci, O
    Durak, I
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (05) : 494 - 499
  • [10] Lens-thickness correlation with pseudophakic anterior chamber depth
    Galvis, Virgilio
    Tello, Alejandro
    Frederick, Gabriel A.
    Serrano, Andres
    Camacho, Paul A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (04): : 645 - 646