Measuring anterior chamber depth with the Orbscan Topography System

被引:81
|
作者
Auffarth, GU
Tetz, MR
Biazid, Y
Volcker, HE
机构
[1] Department of Ophthalmology, Ruprecht-Karls-Univ. of Heidelberg, D-69120 Heidelberg
来源
关键词
D O I
10.1016/S0886-3350(97)80114-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the reliability of the Orbscan Topography System in measuring anterior chamber depth (ACD). Setting: Department of Ophthalmology, Ruprecht-Karls-University of Heidelberg, Heidelberg, Germany. Methods: The Orbscan Topography System is a 3-D, scanning slit beam system for analyzing corneal surfaces as well as structures of the anterior segment, e.g., iris, lens. Reflected surface data points are measured in the x, y, and z axes, creating color-coded true surface topography maps. We measured ACD prior to cataract surgery in 56 eyes of 37 patients (mean age 70.4 years + 13.2 [SD]) using the Orbscan system and, as a control, the Grieshaber Biometric System (ultrasound) and the Jager ACD slitlamp measurement system. Results: Mean ACD values measured with the Orbscan system were 3.23 +/- 0.55 mm; ultrasound measurements were 3.27 +/- 0.54 mm and Jager measurements, 3.10 +/- 0.55 mm. The average difference between Orbscan and ultrasound values was 0.04 +/- 0.15 mm. The correlation coefficient between Orbscan and ultrasound was 0.96 (P < .00001) and between Orbscan and Jager, 0.899 (P < .0001). Conclusion: The ACD measurements by the Orbscan system were equivalent to common reference measurements.
引用
收藏
页码:1351 / 1355
页数:5
相关论文
共 50 条
  • [1] Anterior chamber depth in relation to refractive status measured with the Orbscan II Topography System
    Rabsilber, TM
    Becker, KA
    Frisch, IB
    Auffarth, GU
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (11): : 2115 - 2121
  • [2] Comparasion of Orbscan II Topography and Ultrasound Biometry in the Measurement of Anterior Chamber Depth
    Zengin, Ozgur
    Selver, Ozlem Barut
    Ozbek, Zeynep
    Yaman, Aylin
    Durak, Ismel
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2009, 39 (01): : 27 - 31
  • [3] Evaluation of anterior chamber depth and iridocorneal angle with Orbscan II slit scanning system
    Schroeder, A
    Ueckerseifer, F
    Bader, C
    Gockeln, R
    Erb, C
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U968 - U968
  • [4] Validity and Repeatability of Anterior Chamber Depth Measurements With Pentacam and Orbscan
    Lackner, Birgit
    Schmidinger, Gerald
    Skorpik, Christian
    OPTOMETRY AND VISION SCIENCE, 2005, 82 (09) : 858 - 861
  • [5] Comparison of anterior chamber depth measurements using Orbscan II and IOLMaster
    Frisch, I. B.
    Rabsilber, T. M.
    Becker, K. A.
    Reuland, A. J.
    Auffarth, G. U.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2007, 17 (03) : 327 - 331
  • [6] Comparative estimation of anterior chamber depth by ultrasonography, Orbscan II, and IOLMaster
    Reddy, AR
    Pande, MV
    Finn, P
    El-Gogary, H
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (06): : 1268 - 1271
  • [7] Comparison of anterior chamber depth measurement between Orbscan IIz and ultrasound biomicroscopy
    Lee, Jong Yun
    Kim, Jun-Heon
    Kim, Hyo-Myung
    Song, Jong-Suk
    JOURNAL OF REFRACTIVE SURGERY, 2007, 23 (05) : 487 - 491
  • [8] Comparison of techniques for measuring anterior chamber depth: Orbscan imaging, Smith’s technique, and van Herick’s method
    Frank Eperjesi
    Claire Holden
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2011, 249 : 449 - 454
  • [9] Comparison of techniques for measuring anterior chamber depth: Orbscan imaging, Smith's technique, and van Herick's method
    Eperjesi, Frank
    Holden, Claire
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (03) : 449 - 454
  • [10] Anterior chamber depth measurement with A-scan ultrasonography, Orbscan II, and IOLMaster
    Hashemi, H
    Yazdani, K
    Mehravaran, S
    Fotouhi, A
    OPTOMETRY AND VISION SCIENCE, 2005, 82 (10) : 900 - 904