Measuring anterior chamber depth with the Orbscan Topography System

被引:81
|
作者
Auffarth, GU
Tetz, MR
Biazid, Y
Volcker, HE
机构
[1] Department of Ophthalmology, Ruprecht-Karls-Univ. of Heidelberg, D-69120 Heidelberg
来源
关键词
D O I
10.1016/S0886-3350(97)80114-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the reliability of the Orbscan Topography System in measuring anterior chamber depth (ACD). Setting: Department of Ophthalmology, Ruprecht-Karls-University of Heidelberg, Heidelberg, Germany. Methods: The Orbscan Topography System is a 3-D, scanning slit beam system for analyzing corneal surfaces as well as structures of the anterior segment, e.g., iris, lens. Reflected surface data points are measured in the x, y, and z axes, creating color-coded true surface topography maps. We measured ACD prior to cataract surgery in 56 eyes of 37 patients (mean age 70.4 years + 13.2 [SD]) using the Orbscan system and, as a control, the Grieshaber Biometric System (ultrasound) and the Jager ACD slitlamp measurement system. Results: Mean ACD values measured with the Orbscan system were 3.23 +/- 0.55 mm; ultrasound measurements were 3.27 +/- 0.54 mm and Jager measurements, 3.10 +/- 0.55 mm. The average difference between Orbscan and ultrasound values was 0.04 +/- 0.15 mm. The correlation coefficient between Orbscan and ultrasound was 0.96 (P < .00001) and between Orbscan and Jager, 0.899 (P < .0001). Conclusion: The ACD measurements by the Orbscan system were equivalent to common reference measurements.
引用
收藏
页码:1351 / 1355
页数:5
相关论文
共 50 条
  • [31] Anterior Chamber Depth After Phacovitrectomy
    De Bernardo, Maddalena
    Di Paola, Ilenia
    Rosa, Nicola
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 2741 - 2742
  • [32] Assessing the accuracy of Orbscan II post-LASIK: apparent keratectasia is paradoxically associated with anterior chamber depth reduction in successful procedures
    Cairns, G
    Ormonde, SE
    Gray, T
    Hadden, OB
    Morris, T
    Ring, P
    McGhee, CNJ
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 33 (02): : 147 - 152
  • [33] Anterior chamber depth during hemodialysis
    Barbosa Gracitelli, Carolina Pelegrini
    Stefanini, Francisco Rosa
    Penha, Fernando
    Goes, Miguel Angelo
    Draibe, Sergio Antonio
    Canziani, Maria Eugenia
    Junior, Augusto Paranhos
    CLINICAL OPHTHALMOLOGY, 2013, 7 : 1635 - 1639
  • [34] Race gender and anterior chamber depth
    Congdon, NG
    Foster, P
    Seah, S
    Spaeth, GL
    Wamsley, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S566 - S566
  • [35] SERIAL RECORDINGS OF THE DEPTH OF THE ANTERIOR CHAMBER
    BLEEKER, GM
    ARCHIVES OF OPHTHALMOLOGY, 1960, 63 (05) : 821 - 829
  • [36] Anterior chamber depth measurement variation
    Seah, SKL
    Foster, PJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 812 - 812
  • [37] Determining postoperative anterior chamber depth
    Kriechbaum, K
    Findl, O
    Preussner, PR
    Köppl, C
    Wahl, J
    Drexler, W
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (11): : 2122 - 2126
  • [38] Anterior chamber depth in elderly Chinese
    He, Mingguang
    Huang, Wenyong
    Zheng, Yingfeng
    Alsbirk, Pout Helge
    Foster, Paul J.
    OPHTHALMOLOGY, 2008, 115 (08) : 1286 - 1290
  • [39] Anterior Chamber Depth in Hispanic Population
    Lozano, Jesus
    de Alba, Manuel A.
    Lozano, Juan F.
    Mendoza, Guillermo
    Tamez, Alejandro
    Valdez, Jorge E.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [40] Pseudophakic anterior chamber depth measurement
    Cartwright, N. E. Knox
    Tole, D. M.
    EYE, 2009, 23 (11) : 2120 - 2120