Fatigue lifetime of reduced-diameter implants placed in different bone models

被引:0
|
作者
Tretto, Pedro Henrique Wentz [1 ]
Griggs, Jason Alan [2 ]
Jodha, Kartikeya Singh [2 ]
Duan, Yuanyuan [2 ]
Marocho, Susana Maria Salazar [2 ]
Della Bona, Alvaro [1 ]
机构
[1] Univ Passo Fundo, Sch Dent, Postgrad Program Dent, Campus I,BR 285, BR-99001970 Passo Fundo, RS, Brazil
[2] Univ Mississippi Med Ctr, Biomed Mat Sci, 2500 North State St, Jackson, MS 39216 USA
关键词
Dental implants; Fatigue fractures; Fractographic analysis; COMPUTED-TOMOGRAPHY; VOLUME FRACTION; PARAMETERS; STIFFNESS; FRACTURE;
D O I
10.1016/j.dental.2024.09.003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study assessed the fatigue lifetime of reduced-diameter implants placed in either bovine rib or polymer-based bone model. Methods: Bovine ribs were classified according to the criteria proposed by Lekholm and Zarb and were analyzed for bone fraction. Fourteen dental implants (3.25 mm in diameter x 15 mm in length) were placed in bovine ribs used as a bone model. They were subjected to resonance frequency analysis. Stainless steel loading hemisphere caps were bonded on the abutments position at 30-degree angle and with a moment arm of 11 mm. Accelerated life testing using the step-stress method was conducted at 2 Hz with a stress ratio of 0.1 until fracture on a servohydraulic load frames machine (MTS). Results were compared with those of a previous study wherein implants were placed in a polymer-based bone model. Fatigue lifetime statistics (characteristic lifetime and Weibull modulus) of physical specimens were estimated in a reliability analysis software (ALTA PRO). Fractured specimens were examined under an electron scanning microscope to determine the failure mode. Result: The implants exhibited high stability quotient values (75.07 +/- 3.81). Implants placed in bovine ribs showed better data dispersion and longer fatigue lifetime than those placed in polymer-based bone models, with no significant difference between groups. All fractures occurred in the implant body near the bone level and were indicative of fatigue fractures. Significance: Bovine ribs appear to be a more suitable material for accelerated life testing than the polymer-based material because of better data dispersion.
引用
收藏
页码:1920 / 1926
页数:7
相关论文
共 50 条
  • [21] Dental Implants Placed in Extraction Sites Grafted With Different Bone Substitutes: Radiographic Evaluation at 24 Months
    Crespi, Roberto
    Cappare, Paolo
    Gherlone, Enrico
    JOURNAL OF PERIODONTOLOGY, 2009, 80 (10) : 1616 - 1621
  • [22] A comparative study on the initial stability of different implants placed above the bone level using resonance frequency analysis
    Kang, In-Ho
    Kim, Chang-Whe
    Lim, Young-Jun
    Kim, Myung-Joo
    JOURNAL OF ADVANCED PROSTHODONTICS, 2011, 3 (04): : 190 - 195
  • [23] Biological width formation to immediate implants placed at different level in relation to the crestal bone: an experimental study in dogs
    Negri, Bruno
    Lopez Mari, Marta
    Sanchez de Val, Jose Eduardo Mate
    Iezzi, Giovanna
    Bravo Gonzalez, Luis Alberto
    Calvo Guirado, Jose Luis
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (07) : 788 - 798
  • [24] Assessment of the Correlation Between Insertion Torque and Resonance Frequency Analysis of Implants Placed in Bone Tissue of Different Densities
    Magno Filho, Luiz Carlos
    Cirano, Fabiano Ribeiro
    Hayashi, Fernando
    Feng, Hsu Shao
    Conte, Alexandre
    Dib, Luciano Lauria
    Casati, Marcio Zaffalon
    JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (03) : 259 - 262
  • [25] Primary stability of narrow-diameter dental implants with a multiple condensing thread design placed in bone with and without osteotomes: An in vitro study
    Romanos, Georgios E.
    Lau, Jessica
    Delgado-Ruiz, Rafael
    Javed, Fawad
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (03) : 409 - 414
  • [26] Impact of different placement depths on the crestal bone level of immediate versus delayed placed platform-switched implants
    Madani, Elika
    Smeets, Ralf
    Freiwald, Eric
    Sanj, Maryam Setareh
    Jung, Ole
    Grubeanu, Daniel
    Hanken, Henning
    Henningsen, Anders
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2018, 46 (07) : 1139 - 1146
  • [27] Insertion and removal torque of dental implants placed using different drilling protocols: An experimental study on artificial bone substitutes
    Romeo, Davide
    Chochlidakis, Konstantinos
    Barmak, Abdul Basir
    Agliardi, Enrico
    Lo Russo, Lucio
    Ercoli, Carlo
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (07): : 633 - 638
  • [28] Evaluation of the implant diameter on the initial-stability of narrow- and standard-diameter implants placed in simulated Type-I and Type-IV bone-blocks
    Alresayes, Saad
    Mokeem, Sameer A.
    Alhenaki, Aasem M.
    Vohra, Fahim
    Abduljabbar, Tariq
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2021, 37 (03) : 812 - 815
  • [29] Three-Dimensional Finite Element Analysis of Osseointegrated Implants Placed in Bone of Different Densities With Cemented Fixed Prosthetic Restoration
    Chidambaravalli, Kasthuri
    Krishnan, Vinod
    JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (05) : 480 - 490
  • [30] The Effect of Three Different Crown Heights and Two Different Bone Types on Implants Placed in the Posterior Maxilla: Three-Dimensional Finite Element Analysis
    Cinar, Duygu
    Imirzalioglu, Pervin
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (02) : E1 - E10