Fatigue lifetime of reduced-diameter implants placed in different bone models

被引:0
|
作者
Tretto, Pedro Henrique Wentz [1 ]
Griggs, Jason Alan [2 ]
Jodha, Kartikeya Singh [2 ]
Duan, Yuanyuan [2 ]
Marocho, Susana Maria Salazar [2 ]
Della Bona, Alvaro [1 ]
机构
[1] Univ Passo Fundo, Sch Dent, Postgrad Program Dent, Campus I,BR 285, BR-99001970 Passo Fundo, RS, Brazil
[2] Univ Mississippi Med Ctr, Biomed Mat Sci, 2500 North State St, Jackson, MS 39216 USA
关键词
Dental implants; Fatigue fractures; Fractographic analysis; COMPUTED-TOMOGRAPHY; VOLUME FRACTION; PARAMETERS; STIFFNESS; FRACTURE;
D O I
10.1016/j.dental.2024.09.003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study assessed the fatigue lifetime of reduced-diameter implants placed in either bovine rib or polymer-based bone model. Methods: Bovine ribs were classified according to the criteria proposed by Lekholm and Zarb and were analyzed for bone fraction. Fourteen dental implants (3.25 mm in diameter x 15 mm in length) were placed in bovine ribs used as a bone model. They were subjected to resonance frequency analysis. Stainless steel loading hemisphere caps were bonded on the abutments position at 30-degree angle and with a moment arm of 11 mm. Accelerated life testing using the step-stress method was conducted at 2 Hz with a stress ratio of 0.1 until fracture on a servohydraulic load frames machine (MTS). Results were compared with those of a previous study wherein implants were placed in a polymer-based bone model. Fatigue lifetime statistics (characteristic lifetime and Weibull modulus) of physical specimens were estimated in a reliability analysis software (ALTA PRO). Fractured specimens were examined under an electron scanning microscope to determine the failure mode. Result: The implants exhibited high stability quotient values (75.07 +/- 3.81). Implants placed in bovine ribs showed better data dispersion and longer fatigue lifetime than those placed in polymer-based bone models, with no significant difference between groups. All fractures occurred in the implant body near the bone level and were indicative of fatigue fractures. Significance: Bovine ribs appear to be a more suitable material for accelerated life testing than the polymer-based material because of better data dispersion.
引用
收藏
页码:1920 / 1926
页数:7
相关论文
共 50 条
  • [41] Influence of Inter-Radicular Septal Bone Quantity in Primary Stability of Immediate Molar Implants with Different Length and Diameter Placed in Mandibular Region. A Cone-Beam Computed Tomography-Based Simulated Implant Study
    Sayed, Arshad Jamal
    Shaikh, Safia Shoeb
    Shaikh, Shoeb Yakub
    Hussain, Mohammed Abid
    Tareen, Sabahat Ullah Khan
    Awinashe, Vaibhav
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2021, 13 (05): : 484 - 491
  • [42] RETRACTION: Crestal bone reactions to immediate implants placed at different levels in relation to crestal bone. A pilot study in Foxhound dogs (Retraction of Vol 25, Pg 344, 2014)
    Calvo-Guirado, J. L.
    Boquete-Cast, ro A.
    Negri, B.
    Delgado, Ruiz R.
    Gomez-Moreno, G.
    Iezzi, G.
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (07) : 814 - 814
  • [43] Three-dimensional finite-element analysis of functional stresses in different bone locations produced by implants placed in the maxillary posterior region of the sinus floor
    Koca, OL
    Eskitascioglu, G
    Usumez, A
    JOURNAL OF PROSTHETIC DENTISTRY, 2005, 93 (01): : 38 - 44
  • [44] Comparison of the primary stability achieved by using dental implants with variable thread designs when placed using different drilling techniques. An in vitro bone modular analysis
    Shetty, P. P.
    Chowdhary, R.
    JOURNAL OF OSSEOINTEGRATION, 2023, 15 (01) : 53 - 61
  • [45] Primary Apical Stability of Tapered Implants Through Reduction of Final Drilling Dimensions in Different Bone Density Models: A Biomechanical Study
    Sierra-Rebolledo, Alejandro
    Allais-Leon, Marvis
    Maurette-O'Brien, Paul
    Gay-Escoda, Cosme
    IMPLANT DENTISTRY, 2016, 25 (06) : 775 - 782
  • [46] Clinics Outcome of Implants Placed in Staged Maxillary Sinus Augmentation Using Bovine Bone Mineral Mixed with Autogenous Bone at Three Different Ratios: A 5-Year Prospective Follow-up Study
    Krennmair, Stefan
    Weinlaender, Michael
    Malek, Michael
    Forstner, Thomas
    Krennmair, Gerald
    Stimmelmayr, Michael
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (06) : 1351 - 1361
  • [47] RETRACTION: Peri-implant bone reactions to immediate implants placed at different levels in relation to crestal bone. Part I: a pilot study in dogs (Retraction of Vol 23, Pg 228, 2012)
    Negri, B.
    Calvo-Guirado, J. L.
    Pardo-Zamora, G.
    Ramirez-Fernandez, M. P.
    Delgado-Ruiz, R. A.
    Munoz-Guzon, F.
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (06) : 668 - 668
  • [48] A Prospective Randomized Clinical Trial on Radiographic Crestal Bone Loss Around Dental Implants Placed Using Two Different Drilling Protocols: 12-Month Follow-up
    Tabassum, Afsheen
    Kazmi, Farhat
    Wismeijer, Daniel
    Siddiqui, Intisar Ahmad
    Tahmaseb, Ali
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (06) : E172 - E179
  • [49] Comparison of clinical peri-implant indices and crestal bone levels around narrow and regular diameter implants placed in diabetic and non-diabetic patients: A 3-year follow-up study
    Al-Shibani, Nouf
    Al-Aali, Khulud Abdulrahman
    Al-Hamdan, Rana Sulaiman
    Alrabiah, Mohammed
    Basunbul, Ghadeer
    Abduljabbar, Tariq
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (02) : 247 - 252
  • [50] RETRACTED: Crestal bone reactions to immediate implants placed at different levels in relation to crestal bone. A pilot study in Foxhound dogs (Retracted article. See vol. 29, pg. 814, 2018)
    Calvo-Guirado, Jose L.
    Boquete-Castro, Ana
    Negri, Bruno
    Delgado Ruiz, Rafael
    Gomez-Moreno, Gerardo
    Iezzi, Giovanna
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (03) : 344 - 351