Fatigue lifetime of reduced-diameter implants placed in different bone models

被引:0
|
作者
Tretto, Pedro Henrique Wentz [1 ]
Griggs, Jason Alan [2 ]
Jodha, Kartikeya Singh [2 ]
Duan, Yuanyuan [2 ]
Marocho, Susana Maria Salazar [2 ]
Della Bona, Alvaro [1 ]
机构
[1] Univ Passo Fundo, Sch Dent, Postgrad Program Dent, Campus I,BR 285, BR-99001970 Passo Fundo, RS, Brazil
[2] Univ Mississippi Med Ctr, Biomed Mat Sci, 2500 North State St, Jackson, MS 39216 USA
关键词
Dental implants; Fatigue fractures; Fractographic analysis; COMPUTED-TOMOGRAPHY; VOLUME FRACTION; PARAMETERS; STIFFNESS; FRACTURE;
D O I
10.1016/j.dental.2024.09.003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study assessed the fatigue lifetime of reduced-diameter implants placed in either bovine rib or polymer-based bone model. Methods: Bovine ribs were classified according to the criteria proposed by Lekholm and Zarb and were analyzed for bone fraction. Fourteen dental implants (3.25 mm in diameter x 15 mm in length) were placed in bovine ribs used as a bone model. They were subjected to resonance frequency analysis. Stainless steel loading hemisphere caps were bonded on the abutments position at 30-degree angle and with a moment arm of 11 mm. Accelerated life testing using the step-stress method was conducted at 2 Hz with a stress ratio of 0.1 until fracture on a servohydraulic load frames machine (MTS). Results were compared with those of a previous study wherein implants were placed in a polymer-based bone model. Fatigue lifetime statistics (characteristic lifetime and Weibull modulus) of physical specimens were estimated in a reliability analysis software (ALTA PRO). Fractured specimens were examined under an electron scanning microscope to determine the failure mode. Result: The implants exhibited high stability quotient values (75.07 +/- 3.81). Implants placed in bovine ribs showed better data dispersion and longer fatigue lifetime than those placed in polymer-based bone models, with no significant difference between groups. All fractures occurred in the implant body near the bone level and were indicative of fatigue fractures. Significance: Bovine ribs appear to be a more suitable material for accelerated life testing than the polymer-based material because of better data dispersion.
引用
收藏
页码:1920 / 1926
页数:7
相关论文
共 50 条
  • [11] Crestal Bone Changes Around Implants With Reduced Abutment Diameter Placed Non-Submerged and at Subcrestal Positions: A 1-Year Radiographic Evaluation
    Donovan, Ryan
    Fetner, Alan
    Koutouzis, Theofilos
    Lundgren, Tord
    JOURNAL OF PERIODONTOLOGY, 2010, 81 (03) : 428 - 434
  • [12] Biomechanical analysis of the effects of implant diameter and bone quality in short implants placed in the atrophic posterior maxilla
    Chang, Shih-Hao
    Lin, Chun-Li
    Hsue, Shue-Sang
    Lin, Yang-Sung
    Huang, Shiang-Rung
    MEDICAL ENGINEERING & PHYSICS, 2012, 34 (02) : 153 - 160
  • [13] Stress Analysis Around Reduced-Diameter Zirconia and Titanium One-Piece Implants With and Without Microthreads in the Neck: Experiments and Finite Element Analysis
    Al-Zordk, Walid
    Ghazy, Mohamed
    El-Anwar, Mohamed
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (02) : 305 - 312
  • [14] Clinical and radiographic indices around narrow diameter implants placed in different glycemic-level patients
    Alsahhaf, Abdulaziz
    Alshiddi, Ibraheem F.
    Alshagroud, Rana Saud
    Al-Aali, Khulud Abdulrahman
    Vohra, Fahim
    Abduljabbar, Tariq
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (04) : 621 - 626
  • [15] Deviation of Dental Implants Placed by Guided Implant Surgery in Bone Structures with Different Densities
    Dere, Kadriye Ayca
    Sahin, Sezgi Cinel
    Ozdede, Melih
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (02) : 268 - 276
  • [16] The Biomechanical Investigation of Osseointegration Levels in Titanium Implants Simultaniously Placed with Different Bone Grafts
    Guler, R.
    Dundar, S.
    Bozoglan, A.
    Ozcan, E. c
    Ozupek, M. f
    Acikan, I
    Gunes, N.
    Bingul, M. b
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2024, 27 (03) : 310 - 316
  • [17] Biomechanical Investigation of the Osseointegration of Titanium Implants With Different Surfaces Placed With Allogeneic Bone Transfer
    Ozcan, Erhan Cahit
    Aydin, Melek Atille
    Dundar, Serkan
    Tanrisever, Murat
    Bal, Ali
    Karasu, Necmettin
    Kirtay, Mustafa
    JOURNAL OF CRANIOFACIAL SURGERY, 2024, 35 (07) : 2184 - 2188
  • [18] Clinical performance of monolithic zirconia crowns on titanium-zirconium reduced-diameter implants in the molar area: Interim data at three years of a randomized controlled trial
    Zumstein, K.
    Waller, T.
    Hammerle, C. H. F.
    Jung, R. E.
    Benic, G.
    Muhlemann, S.
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (12) : 1354 - 1362
  • [19] Narrow-diameter versus standard-diameter implants placed in horizontally regenerated bone in the rehabilitation of partially and completely edentulous patients: A systematic review
    Valente, Nicola Alberto
    Marchio, Vincenzo
    Troiano, Giuseppe
    Gasparro, Roberta
    Balice, Pierluigi
    Marenzi, Gaetano
    Laino, Luigi
    Sammartino, Gilberto
    Iezzi, Giovanna
    Barone, Antonio
    INTERNATIONAL JOURNAL OF ORAL IMPLANTOLOGY, 2022, 15 (01) : 13 - 29
  • [20] Bone remodeling at implants with different configurations and placed immediately at different depth into extraction sockets. Experimental study in dogs
    Luis Calvo-Guirado, Jose
    Gomez Moreno, Gerardo
    Aguilar-Salvatierra, Antonio
    de Val, Jose Eduardo Mate Sanchez
    Abboud, Marcus
    Nemcovsky, Carlos E.
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (05) : 507 - 515