Fatigue lifetime of reduced-diameter implants placed in different bone models

被引:0
|
作者
Tretto, Pedro Henrique Wentz [1 ]
Griggs, Jason Alan [2 ]
Jodha, Kartikeya Singh [2 ]
Duan, Yuanyuan [2 ]
Marocho, Susana Maria Salazar [2 ]
Della Bona, Alvaro [1 ]
机构
[1] Univ Passo Fundo, Sch Dent, Postgrad Program Dent, Campus I,BR 285, BR-99001970 Passo Fundo, RS, Brazil
[2] Univ Mississippi Med Ctr, Biomed Mat Sci, 2500 North State St, Jackson, MS 39216 USA
关键词
Dental implants; Fatigue fractures; Fractographic analysis; COMPUTED-TOMOGRAPHY; VOLUME FRACTION; PARAMETERS; STIFFNESS; FRACTURE;
D O I
10.1016/j.dental.2024.09.003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study assessed the fatigue lifetime of reduced-diameter implants placed in either bovine rib or polymer-based bone model. Methods: Bovine ribs were classified according to the criteria proposed by Lekholm and Zarb and were analyzed for bone fraction. Fourteen dental implants (3.25 mm in diameter x 15 mm in length) were placed in bovine ribs used as a bone model. They were subjected to resonance frequency analysis. Stainless steel loading hemisphere caps were bonded on the abutments position at 30-degree angle and with a moment arm of 11 mm. Accelerated life testing using the step-stress method was conducted at 2 Hz with a stress ratio of 0.1 until fracture on a servohydraulic load frames machine (MTS). Results were compared with those of a previous study wherein implants were placed in a polymer-based bone model. Fatigue lifetime statistics (characteristic lifetime and Weibull modulus) of physical specimens were estimated in a reliability analysis software (ALTA PRO). Fractured specimens were examined under an electron scanning microscope to determine the failure mode. Result: The implants exhibited high stability quotient values (75.07 +/- 3.81). Implants placed in bovine ribs showed better data dispersion and longer fatigue lifetime than those placed in polymer-based bone models, with no significant difference between groups. All fractures occurred in the implant body near the bone level and were indicative of fatigue fractures. Significance: Bovine ribs appear to be a more suitable material for accelerated life testing than the polymer-based material because of better data dispersion.
引用
收藏
页码:1920 / 1926
页数:7
相关论文
共 50 条
  • [31] Evaluation of four designs of short implants placed in atrophic areas with reduced bone height: a three-year, retrospective, clinical and radiographic study
    Lopez Torres, J. A.
    Gehrke, S. A.
    Calvo Guirado, J. L.
    Aristazabal, L. F. R.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2017, 55 (07): : 703 - 708
  • [32] Fatigue lifetime under uniaxial random loading with different mean values according to some selected models
    Kluger, Krzysztof
    Lagoda, Tadeusz
    MATERIALS & DESIGN, 2007, 28 (10) : 2604 - 2610
  • [33] Comparison of Periodontal Health and Marginal Bone Loss in Mandibular First Molar Single-Crown Dental Implants Placed in Different Positions
    Dereci Ö.
    Mumcu E.
    Gojayeva G.
    Dayan Ç.
    Journal of Long-Term Effects of Medical Implants, 2023, 33 (04) : 59 - 65
  • [34] A prospective, randomized-controlled clinical trial to evaluate bone preservation using implants with different geometry placed into extraction sockets in the maxilla
    Sanz, Mariano
    Cecchinato, Denis
    Ferrus, Jorge
    Pjetursson, E. Bjarni
    Lang, Niklaus P.
    Lindhe, Jan
    CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (01) : 13 - 21
  • [35] Marginal Bone Loss in Posterior Implants Placed at Different Levels and Different Prosthetic Designs: A Retrospective Study With a Minimum of 1-Year Follow-Up
    Kasabreh, Najla S.
    Khurshid, Hadyia
    Khan, Musa Q.
    Malaikah, Shima
    Wang, Hom-Lay
    JOURNAL OF ORAL IMPLANTOLOGY, 2024, 50 (03) : 232 - 237
  • [36] Probability of Failure of Internal Hexagon and Morse Taper Implants with Different Bone Levels: A Mechanical Test and Probabilistic Fatigue
    Prados-Privado, Maria
    Gehrke, Sergio A.
    Rojo, Rosa
    Prados-Frutos, Juan Carlos
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (06) : 1266 - 1273
  • [37] Crestal bone loss around dental implants placed in head and neck cancer patients treated with different radiotherapy techniques: a prospective cohort study
    Papi, P.
    Brauner, E.
    Di Carlo, S.
    Musio, D.
    Tombolini, M.
    De Angelis, F.
    Valentini, V.
    Tombolini, V.
    Polimeni, A.
    Pompa, G.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2019, 48 (05) : 691 - 696
  • [38] Immediate and delayed loading of two-piece reduced-diameter implants with locator-analog attachments in edentulous mandibles: One-year results from a randomized clinical trial examining clinical outcome and patient expectation
    Giannakopoulos, Nikolaos Nikitas
    Ariaans, Kirsten
    Eberhard, Lydia
    Klotz, Anna-Luisa
    Oh, Keunyoung
    Kappel, Stefanie
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (04) : 643 - 653
  • [39] Randomised study for the 1-year crestal bone maintenance around modified diameter implants with different loading protocols: a radiographic evaluation
    Danza, Matteo
    Tortora, Pietro
    Quaranta, Alessandro
    Perrotti, Vittoria
    Vozza, Iole
    Piattelli, Adriano
    CLINICAL ORAL INVESTIGATIONS, 2010, 14 (04) : 417 - 426
  • [40] Randomised study for the 1-year crestal bone maintenance around modified diameter implants with different loading protocols: a radiographic evaluation
    Matteo Danza
    Pietro Tortora
    Alessandro Quaranta
    Vittoria Perrotti
    Iole Vozza
    Adriano Piattelli
    Clinical Oral Investigations, 2010, 14 : 417 - 426