The Effect of Three Different Crown Heights and Two Different Bone Types on Implants Placed in the Posterior Maxilla: Three-Dimensional Finite Element Analysis

被引:11
|
作者
Cinar, Duygu [1 ]
Imirzalioglu, Pervin [1 ]
机构
[1] Baskent Univ, Fac Dent, Dept Prosthodont, 82 St 26 Bahcelievler Cankaya, Ankara, Turkey
关键词
single-tooth implants; crown-implant ratio; crown length; LIFE TABLE ANALYSIS; STRESS-DISTRIBUTION; DENTAL IMPLANTS; OSSEOINTEGRATED IMPLANTS; EDENTULOUS MAXILLAE; TOOTH EXTRACTION; SUPPORTING BONE; CERVICAL LESION; ORAL IMPLANTS; ITI-IMPLANTS;
D O I
10.11607/jomi.4048
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purose: The purpose of this study was to determine the amount and localization of functional stresses in implants placed in two different bone types (type 3 and type 4) with three different crown heights in the atrophic posterior maxilla using finite element analysis. Materials and Methods: A three-dimensional finite element model of the posterior maxilla was created from a computerized tomography image by using the Marc 2005 (MSC Software) program. Three different crown/implant ratios (1/1, 1.5/1, 2/1) in the first molar tooth zone were modeled. Type 3 and type 4 bone quality according to the classiication system of Lekholm and Zarb was created. The total oblique force of 300 N with a 30-degree angle was applied from the locations of the mesiobuccal cusp (150 N) and the distobuccal cusp (150 N) of first molar teeth. Results: For the implants, the highest stresses were observed around the implant neck at the crown/implant ratio of 2/1 (430.57 MPa). As the crown/implant ratio increased two times, the von Mises stresses increased at a rate of 47%. The highest tensile values exceeded the ultimate tensile strength of the cortical bone for all the designs. Also, the highest compressive values exceeded the ultimate compressive strength of the cortical bone in the 2/1 design for type 3 bone, and in the 1.5/1 and 2/1 designs for type 4 bone. As the crown/implant ratio increased from 1/1 to 2/1, the highest tensile value and the highest compressive value increased 13%. For the spongious bone, as the crown/implant ratio increased, the highest tensile value increased 42% and 85%, respectively. Tensile stresses increased at a rate of 26% in the 1/1 ratio, 30% in the 1.5/1 ratio, and 32% in the 2/1 ratio when the density of spongious bone decreased. Compression-related values also increased 34% in the 1/1 ratio, 35% in the 1.5/1 ratio, and 36% in the 2/1 ratio when the density of spongious bone decreased. Conclusion: Compressive and tensile stresses formed mostly at the alveolar bone around the implant neck that was cortical bone. Thus, it had to be preserved during the surgical procedures. Deformation due to the stresses had great importance for the type IV spongious bone due to the increase caused by the higher crown height levels.
引用
收藏
页码:E1 / E10
页数:10
相关论文
共 50 条
  • [1] Three-Dimensional Finite Element Analysis of Osseointegrated Implants Placed in Bone of Different Densities With Cemented Fixed Prosthetic Restoration
    Chidambaravalli, Kasthuri
    Krishnan, Vinod
    JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (05) : 480 - 490
  • [2] Three-dimensional Finite Element Analysis of Implants with Different Crown-to-Root Ratio and Different High Thread
    Duan, Yingjie
    Chen, Ling
    Xiong, Tao
    Niu, Xinghua
    EXPERIMENTAL AND APPLIED MECHANICS, 2014, 518 : 190 - 195
  • [3] Splinted and Nonsplinted Crowns with Different Implant Lengths in the Posterior Maxilla by Three-Dimensional Finite Element Analysis
    Araujo Lemos, Cleidiel Aparecido
    Verri, Fellippo Ramos
    Santiago Junior, Joel Ferreira
    de Souza Batista, Victor Eduardo
    Kemmoku, Daniel Takanori
    Noritomi, Pedro Yoshito
    Pellizzer, Eduardo Piza
    JOURNAL OF HEALTHCARE ENGINEERING, 2018, 2018
  • [4] Three-dimensional finite-element analysis of functional stresses in different bone locations produced by implants placed in the maxillary posterior region of the sinus floor
    Koca, OL
    Eskitascioglu, G
    Usumez, A
    JOURNAL OF PROSTHETIC DENTISTRY, 2005, 93 (01): : 38 - 44
  • [5] Three-Dimensional Finite Element Analysis of the Effect of Endosteal Implants with Different Macro Designs on Stress Distribution in Different Bone Qualities
    Yalcin, Mustafa
    Kaya, Beyza
    Lacin, Nihat
    Ari, Emre
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (03) : E43 - E50
  • [6] Three-dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown
    Sevimay, M
    Turhan, F
    Kiliçarslan, MA
    Eskitascioglu, G
    JOURNAL OF PROSTHETIC DENTISTRY, 2005, 93 (03): : 227 - 234
  • [7] Effect of different restorative crown and customized abutment materials on stress distribution in single implants and peripheral bone: A three-dimensional finite element analysis study
    Kaleli, Necati
    Sarac, Duygu
    Kulunk, Safak
    Ozturk, Ozgur
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (03): : 437 - 445
  • [8] Evaluation of Stresses Occurring on Three Different Zirconia Dental Implants: Three-Dimensional Finite Element Analysis
    Caglar, Alper
    Bal, Bilge Turhan
    Aydin, Cemal
    Yilmaz, Handan
    Ozkan, Secil
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (01) : 95 - 103
  • [9] Three-dimensional finite element analysis of stress distribution on short implants with different bone conditions and osseointegration rates
    Yunhe Yang
    Yuchen Liu
    Xi Yuan
    Mingfa Ren
    Xiaodong Chen
    Lailong Luo
    Lang Zheng
    Yang Liu
    BMC Oral Health, 23
  • [10] Three-dimensional finite element analysis of stress distribution on short implants with different bone conditions and osseointegration rates
    Yang, Yunhe
    Liu, Yuchen
    Yuan, Xi
    Ren, Mingfa
    Chen, Xiaodong
    Luo, Lailong
    Zheng, Lang
    Liu, Yang
    BMC ORAL HEALTH, 2023, 23 (01)