The Effect of Three Different Crown Heights and Two Different Bone Types on Implants Placed in the Posterior Maxilla: Three-Dimensional Finite Element Analysis

被引:11
|
作者
Cinar, Duygu [1 ]
Imirzalioglu, Pervin [1 ]
机构
[1] Baskent Univ, Fac Dent, Dept Prosthodont, 82 St 26 Bahcelievler Cankaya, Ankara, Turkey
关键词
single-tooth implants; crown-implant ratio; crown length; LIFE TABLE ANALYSIS; STRESS-DISTRIBUTION; DENTAL IMPLANTS; OSSEOINTEGRATED IMPLANTS; EDENTULOUS MAXILLAE; TOOTH EXTRACTION; SUPPORTING BONE; CERVICAL LESION; ORAL IMPLANTS; ITI-IMPLANTS;
D O I
10.11607/jomi.4048
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purose: The purpose of this study was to determine the amount and localization of functional stresses in implants placed in two different bone types (type 3 and type 4) with three different crown heights in the atrophic posterior maxilla using finite element analysis. Materials and Methods: A three-dimensional finite element model of the posterior maxilla was created from a computerized tomography image by using the Marc 2005 (MSC Software) program. Three different crown/implant ratios (1/1, 1.5/1, 2/1) in the first molar tooth zone were modeled. Type 3 and type 4 bone quality according to the classiication system of Lekholm and Zarb was created. The total oblique force of 300 N with a 30-degree angle was applied from the locations of the mesiobuccal cusp (150 N) and the distobuccal cusp (150 N) of first molar teeth. Results: For the implants, the highest stresses were observed around the implant neck at the crown/implant ratio of 2/1 (430.57 MPa). As the crown/implant ratio increased two times, the von Mises stresses increased at a rate of 47%. The highest tensile values exceeded the ultimate tensile strength of the cortical bone for all the designs. Also, the highest compressive values exceeded the ultimate compressive strength of the cortical bone in the 2/1 design for type 3 bone, and in the 1.5/1 and 2/1 designs for type 4 bone. As the crown/implant ratio increased from 1/1 to 2/1, the highest tensile value and the highest compressive value increased 13%. For the spongious bone, as the crown/implant ratio increased, the highest tensile value increased 42% and 85%, respectively. Tensile stresses increased at a rate of 26% in the 1/1 ratio, 30% in the 1.5/1 ratio, and 32% in the 2/1 ratio when the density of spongious bone decreased. Compression-related values also increased 34% in the 1/1 ratio, 35% in the 1.5/1 ratio, and 36% in the 2/1 ratio when the density of spongious bone decreased. Conclusion: Compressive and tensile stresses formed mostly at the alveolar bone around the implant neck that was cortical bone. Thus, it had to be preserved during the surgical procedures. Deformation due to the stresses had great importance for the type IV spongious bone due to the increase caused by the higher crown height levels.
引用
收藏
页码:E1 / E10
页数:10
相关论文
共 50 条
  • [31] Bone Stress Analysis of Various Angulations of Mesiodistal Implants with Splinted Crowns in the Posterior Mandible: A Three-Dimensional Finite Element Study
    Lan, Ting-Hsun
    Pan, Chin-Yun
    Lee, Huey-Er
    Huang, Heng-Li
    Wang, Chau-Hsiang
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (04) : 763 - 770
  • [32] Three-Dimensional Finite Element Analysis of Prosthetic Finger Joint Implants
    E.A. Biddis
    E.R. Bogoch
    S.A. Meguid
    International Journal of Mechanics and Materials in Design, 2004, 1 (4) : 317 - 328
  • [33] Stress distribution and displacement with four different types of MARPE on craniofacial complex: A three-dimensional finite element analysis
    Gupta, Veenita
    Rai, Priyank
    Tripathi, Tulika
    Kanase, Anup
    INTERNATIONAL ORTHODONTICS, 2023, 21 (04)
  • [34] Three-dimensional finite-element analysis of two ceramic inlay restorations with different cavity designs
    Guven, Sedat
    Akdogan, Mehmet
    Oz, Cihan
    Dogan, Mehmet Sinan
    Unal, Mehmet
    Unal, Server
    Sahbaz, Cafer
    BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2015, 29 (03) : 579 - 585
  • [35] Three-dimensional finite element analysis of the maxillary central incisor in two different situations of traumatic impact
    da Silva, B. R.
    Moreira Neto, J. J. S.
    da Silva, F. I., Jr.
    de Aguiar, A. S. W.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2013, 16 (02) : 158 - 164
  • [36] Three-dimensional finite element analysis of three removable partial dentures under different loading conditions
    Cui, Wen
    Wang, Dong-Mei
    Wang, Cheng-Tao
    Huang, Qing-Feng
    Zhang, Fu-Qiang
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2010, 44 (11): : 1588 - 1594
  • [37] Influence of Thread Pitch, Helix Angle, and Compactness on Micromotion of Immediately Loaded Implants in Three Types of Bone Quality: A Three-Dimensional Finite Element Analysis
    Ma, Pan
    Xiong, Wei
    Tan, Baosheng
    Geng, Wei
    Liu, Jiaqiang
    Li, Weihong
    Li, Dehua
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [38] Influence of different implant-abutment connections on stress distribution in single tilted implants and peripheral bone: A three-dimensional finite element analysis
    Ozturk, Ozgur
    Kulunk, Tolga
    Kulunk, Safak
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2018, 29 (04) : 513 - 526
  • [39] Stress distribution and displacement by different bone-borne palatal expanders with micro-implants: a three-dimensional finite-element analysis
    Lee, Hye Kyung
    Bayome, Mohamed
    Ahn, Chee Soo
    Kim, Seong-Hun
    Kim, Ki Beom
    Mo, Sung-Seo
    Kook, Yoon-Ah
    EUROPEAN JOURNAL OF ORTHODONTICS, 2014, 36 (05) : 531 - 540
  • [40] Evaluation of Different Heights of Prosthetic Crowns Supported by an Ultra-Short Implant Using Three-Dimensional Finite Element Analysis
    Elias, Douglas Maximo
    Valerio, Claudia Scigliano
    de Oliveira, Dauro Douglas
    Manzi, Flavio Ricardo
    Zenobio, Elton Goncalves
    Seraidarian, Paulo Isaias
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2020, 33 (01) : 81 - 90