INTEGRATION OF THERMAL ENERGY STORAGE MATERIALS IN HEAT PIPE EVACUATED TUBE SOLAR COLLECTOR SYSTEMS FOR ENHANCED SOLAR THERMAL PERFORMANCE

被引:0
|
作者
Hachim, Dhafer Manea [1 ]
Eidan, Adel A. [1 ]
Alshukri, Mohammed J. [2 ,3 ]
Al-Fahham, Mohamed [1 ]
Alsahlani, Assaad [1 ]
Al-Manea, Ahmed [4 ]
Al-Rbaihat, Raed [5 ]
Alahmer, Ali [6 ]
机构
[1] Al Furat Al Awsat Tech Univ, Engn Tech Coll, Al Najaf 31001, Iraq
[2] Kufa Univ, Fac Engn, Dept Mech Engn, Najaf 54002, Iraq
[3] Islamic Univ, Coll Tech Engn, Refrigerat & Air Conditioning Tech Engn Dept, Najaf, Iraq
[4] Al Furat Al Awsat Tech Univ, Dept Mech Engn, Najaf, Iraq
[5] Tafila Tech Univ, Fac Engn, Dept Mech Engn, POB 179, Tafila 66110, Jordan
[6] Tuskegee Univ, Dept Mech Engn, Tuskegee, AL 36088 USA
来源
COMPUTATIONAL THERMAL SCIENCES | 2024年 / 16卷 / 06期
关键词
solar water heater; evacuated tube; heat pipe solar collector; thermal energy storage; phase change material; numerical; PHASE-CHANGE MATERIALS; NUMERICAL-ANALYSIS; BUILDINGS; PCM;
D O I
10.1615/ComputThermalScien.2024053130
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study investigates integrating thermal energy storage materials (TESM) with a heat pipe evacuated tube solar collector (HP-ETSC) in a water tank. Three TESMs (paraffin wax, RT27, and RT35) were examined numerically using COMSOL software, and experiments were conducted. Different design parameters were discussed, including water tank thickness, TESM tank thickness, TESM types, flow rate, and environmental conditions. The integration of TESM into the HP-ETSC allows the evaluation of various thermal performances, including average water tank temperature, hot water outlet temperature, and duration of hot water availability after sunset. The findings indicate a maximum temperature difference of approximately 37 degrees C at 13:00 on March 19 without TESM. However, with RT35, the temperature difference is around 34.27 degrees C, and with RT27, it is approximately 33.4 degrees C. Additionally, the temperature difference is approximately 2 degrees C higher when TESM is not utilized during the three months at sunset. These results demonstrate improved thermal performance compared to a similar system without TESM. Thermal energy transmission from TESM to water is relatively low, resulting in slightly higher outlet water temperature at night. During cloudy periods, RT27 and RT35 TESM types maintain their melting temperature from 11:00 to 20:00. A water storage tank thickness of 35 mm yields the highest temperature difference with RT27 and RT35 TESM. Increasing TESM thickness allows for more mass and latent heat storage, leading to up to 3.5 hours of heat release. On a mostly sunny day, such as January 9, the HP-ETSC stops heat release around 16:30 without TESM, while the TESM plates prolong the discharge duration by three hours.
引用
收藏
页码:59 / 85
页数:28
相关论文
共 50 条
  • [31] Optimization and thermal performance of evacuated tube solar collector with various nanofluids
    Yurddas, Ali
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 152
  • [32] Estimation and optimization of thermal performance of evacuated tube solar collector system
    Erkan Dikmen
    Mahir Ayaz
    H. Hüseyin Ezen
    Ecir U. Küçüksille
    Arzu Şencan Şahin
    Heat and Mass Transfer, 2014, 50 : 711 - 719
  • [33] Estimation and optimization of thermal performance of evacuated tube solar collector system
    Dikmen, Erkan
    Ayaz, Mahir
    Ezen, H. Huseyin
    Kucuksille, Ecir U.
    Sahin, Arzu Sencan
    HEAT AND MASS TRANSFER, 2014, 50 (05) : 711 - 719
  • [34] EVACUATED HEAT PIPE SOLAR COLLECTOR
    MAHDJURI, F
    ENERGY CONVERSION, 1979, 19 (02): : 85 - 90
  • [35] AN INTERNAL CUSP REFLECTOR FOR AN EVACUATED TUBULAR HEAT PIPE SOLAR THERMAL COLLECTOR
    ORTABASI, U
    BUEHL, WM
    SOLAR ENERGY, 1980, 25 (01) : 67 - 78
  • [36] CUSP MIRROR-HEAT PIPE EVACUATED TUBULAR SOLAR THERMAL COLLECTOR
    ORTABASI, U
    FEHLNER, FP
    SOLAR ENERGY, 1980, 24 (05) : 477 - 489
  • [37] Enhanced honey badger optimization of performance analysis of evacuated tube heat pipe solar collector integrated with PCM storage unit
    Ramesh, C.
    Vijayakumar, M.
    Kumaresan, G.
    Selvanayagam, Benjamin Franklin
    ENERGY & ENVIRONMENT, 2023,
  • [38] Experimental evaluation of a self storage integrated evacuated tube solar thermal collector
    Aramesh, Mohamad
    Shabani, Bahman
    JOURNAL OF ENERGY STORAGE, 2023, 62
  • [39] Enhanced performance assessment of an integrated evacuated tube and flat plate collector solar air heater with thermal storage material
    El-Fakharany, Magda K.
    Abo-Samra, Aly-Eldeen A.
    Abdelmaqsoud, A. M.
    Marzouk, S. A.
    APPLIED THERMAL ENGINEERING, 2024, 243
  • [40] Thermochemical energy storage materials for combination with solar thermal collector systems
    Mueller, Danny
    Knoll, Christian
    Welch, Jan
    Werner, Andreas
    Harasek, Michael
    Schnabl, Christoph
    Weinberger, Peter
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257