INTEGRATION OF THERMAL ENERGY STORAGE MATERIALS IN HEAT PIPE EVACUATED TUBE SOLAR COLLECTOR SYSTEMS FOR ENHANCED SOLAR THERMAL PERFORMANCE

被引:0
|
作者
Hachim, Dhafer Manea [1 ]
Eidan, Adel A. [1 ]
Alshukri, Mohammed J. [2 ,3 ]
Al-Fahham, Mohamed [1 ]
Alsahlani, Assaad [1 ]
Al-Manea, Ahmed [4 ]
Al-Rbaihat, Raed [5 ]
Alahmer, Ali [6 ]
机构
[1] Al Furat Al Awsat Tech Univ, Engn Tech Coll, Al Najaf 31001, Iraq
[2] Kufa Univ, Fac Engn, Dept Mech Engn, Najaf 54002, Iraq
[3] Islamic Univ, Coll Tech Engn, Refrigerat & Air Conditioning Tech Engn Dept, Najaf, Iraq
[4] Al Furat Al Awsat Tech Univ, Dept Mech Engn, Najaf, Iraq
[5] Tafila Tech Univ, Fac Engn, Dept Mech Engn, POB 179, Tafila 66110, Jordan
[6] Tuskegee Univ, Dept Mech Engn, Tuskegee, AL 36088 USA
来源
COMPUTATIONAL THERMAL SCIENCES | 2024年 / 16卷 / 06期
关键词
solar water heater; evacuated tube; heat pipe solar collector; thermal energy storage; phase change material; numerical; PHASE-CHANGE MATERIALS; NUMERICAL-ANALYSIS; BUILDINGS; PCM;
D O I
10.1615/ComputThermalScien.2024053130
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study investigates integrating thermal energy storage materials (TESM) with a heat pipe evacuated tube solar collector (HP-ETSC) in a water tank. Three TESMs (paraffin wax, RT27, and RT35) were examined numerically using COMSOL software, and experiments were conducted. Different design parameters were discussed, including water tank thickness, TESM tank thickness, TESM types, flow rate, and environmental conditions. The integration of TESM into the HP-ETSC allows the evaluation of various thermal performances, including average water tank temperature, hot water outlet temperature, and duration of hot water availability after sunset. The findings indicate a maximum temperature difference of approximately 37 degrees C at 13:00 on March 19 without TESM. However, with RT35, the temperature difference is around 34.27 degrees C, and with RT27, it is approximately 33.4 degrees C. Additionally, the temperature difference is approximately 2 degrees C higher when TESM is not utilized during the three months at sunset. These results demonstrate improved thermal performance compared to a similar system without TESM. Thermal energy transmission from TESM to water is relatively low, resulting in slightly higher outlet water temperature at night. During cloudy periods, RT27 and RT35 TESM types maintain their melting temperature from 11:00 to 20:00. A water storage tank thickness of 35 mm yields the highest temperature difference with RT27 and RT35 TESM. Increasing TESM thickness allows for more mass and latent heat storage, leading to up to 3.5 hours of heat release. On a mostly sunny day, such as January 9, the HP-ETSC stops heat release around 16:30 without TESM, while the TESM plates prolong the discharge duration by three hours.
引用
收藏
页码:59 / 85
页数:28
相关论文
共 50 条
  • [11] Experimental studies of thermal performance of an evacuated tube heat pipe solar collector in Polish climatic conditions
    Alicja Siuta-Olcha
    Tomasz Cholewa
    Kinga Dopieralska-Howoruszko
    Environmental Science and Pollution Research, 2021, 28 : 14319 - 14328
  • [12] Experimental analysis of thermal performance according to heat pipe working fluids for evacuated tube solar collector
    Hong-Jin Joo
    Hee-Youl Kwak
    Heat and Mass Transfer, 2017, 53 : 3267 - 3275
  • [13] Thermal performance of a heat-pipe evacuated-tube solar collector at high inlet temperatures
    Elsheniti, Mahmoud B.
    Kotb, Amr
    Elsamni, Osama
    APPLIED THERMAL ENGINEERING, 2019, 154 : 315 - 325
  • [14] Experimental analysis of thermal performance according to heat pipe working fluids for evacuated tube solar collector
    Joo, Hong-Jin
    Kwak, Hee-Youl
    HEAT AND MASS TRANSFER, 2017, 53 (11) : 3267 - 3275
  • [15] Thermal performance of a solar cooker based on an evacuated tube solar collector with a PCM storage unit
    Sharma, SD
    Iwata, T
    Kitano, H
    Sagara, K
    SOLAR ENERGY, 2005, 78 (03) : 416 - 426
  • [16] Thermal performance and parameter analysis of a U-pipe evacuated solar tube collector
    Gao, Y.
    Fan, R.
    Zhang, X. Y.
    An, Y. J.
    Wang, M. X.
    Gao, Y. K.
    Yu, Y.
    SOLAR ENERGY, 2014, 107 : 714 - 727
  • [17] Thermal performance of heat pipe evacuated tube solar collector integrated with different types of phase change materials at various location
    Alshukri, Mohammed J.
    Eidan, Adel A.
    Najim, Saleh Ismail
    RENEWABLE ENERGY, 2021, 171 : 635 - 646
  • [18] Design of Evacuated Tube Solar Collector with Heat Pipe
    Kumar, S. Siva
    Kumar, K. Mohan
    Kumar, S. R. Sanjeev
    MATERIALS TODAY-PROCEEDINGS, 2017, 4 (14) : 12641 - 12646
  • [19] Evacuated tube solar thermal collector with enhanced phase change material thermal storage: An experimental study
    Senobar, Hossein
    Aramesh, Mohamad
    Shabani, Bahman
    JOURNAL OF ENERGY STORAGE, 2022, 46
  • [20] Theoretical and experimental analysis of thermal performance of a solar water heating system with evacuated tube heat pipe collector
    Daghigh, Roonak
    Shafieian, Abdellah
    APPLIED THERMAL ENGINEERING, 2016, 103 : 1219 - 1227