INTEGRATION OF THERMAL ENERGY STORAGE MATERIALS IN HEAT PIPE EVACUATED TUBE SOLAR COLLECTOR SYSTEMS FOR ENHANCED SOLAR THERMAL PERFORMANCE

被引:0
|
作者
Hachim, Dhafer Manea [1 ]
Eidan, Adel A. [1 ]
Alshukri, Mohammed J. [2 ,3 ]
Al-Fahham, Mohamed [1 ]
Alsahlani, Assaad [1 ]
Al-Manea, Ahmed [4 ]
Al-Rbaihat, Raed [5 ]
Alahmer, Ali [6 ]
机构
[1] Al Furat Al Awsat Tech Univ, Engn Tech Coll, Al Najaf 31001, Iraq
[2] Kufa Univ, Fac Engn, Dept Mech Engn, Najaf 54002, Iraq
[3] Islamic Univ, Coll Tech Engn, Refrigerat & Air Conditioning Tech Engn Dept, Najaf, Iraq
[4] Al Furat Al Awsat Tech Univ, Dept Mech Engn, Najaf, Iraq
[5] Tafila Tech Univ, Fac Engn, Dept Mech Engn, POB 179, Tafila 66110, Jordan
[6] Tuskegee Univ, Dept Mech Engn, Tuskegee, AL 36088 USA
来源
COMPUTATIONAL THERMAL SCIENCES | 2024年 / 16卷 / 06期
关键词
solar water heater; evacuated tube; heat pipe solar collector; thermal energy storage; phase change material; numerical; PHASE-CHANGE MATERIALS; NUMERICAL-ANALYSIS; BUILDINGS; PCM;
D O I
10.1615/ComputThermalScien.2024053130
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study investigates integrating thermal energy storage materials (TESM) with a heat pipe evacuated tube solar collector (HP-ETSC) in a water tank. Three TESMs (paraffin wax, RT27, and RT35) were examined numerically using COMSOL software, and experiments were conducted. Different design parameters were discussed, including water tank thickness, TESM tank thickness, TESM types, flow rate, and environmental conditions. The integration of TESM into the HP-ETSC allows the evaluation of various thermal performances, including average water tank temperature, hot water outlet temperature, and duration of hot water availability after sunset. The findings indicate a maximum temperature difference of approximately 37 degrees C at 13:00 on March 19 without TESM. However, with RT35, the temperature difference is around 34.27 degrees C, and with RT27, it is approximately 33.4 degrees C. Additionally, the temperature difference is approximately 2 degrees C higher when TESM is not utilized during the three months at sunset. These results demonstrate improved thermal performance compared to a similar system without TESM. Thermal energy transmission from TESM to water is relatively low, resulting in slightly higher outlet water temperature at night. During cloudy periods, RT27 and RT35 TESM types maintain their melting temperature from 11:00 to 20:00. A water storage tank thickness of 35 mm yields the highest temperature difference with RT27 and RT35 TESM. Increasing TESM thickness allows for more mass and latent heat storage, leading to up to 3.5 hours of heat release. On a mostly sunny day, such as January 9, the HP-ETSC stops heat release around 16:30 without TESM, while the TESM plates prolong the discharge duration by three hours.
引用
收藏
页码:59 / 85
页数:28
相关论文
共 50 条
  • [21] Prediction of thermal performance of hot water system with the solar collector of concentric evacuated tube using heat pipe
    Chung, Kyung Taek
    Kim, Byoung Gi
    Jang, Hwan Young
    Bae, Chan Hyo
    Suh, Jeong Se
    PROCEEDINGS OF THE 3RD ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING VOLS I AND II, 2006, : 743 - +
  • [22] Thermal performance of a solar pressure cooker based on evacuated tube solar collector
    Kumar, R
    Adhikari, RS
    Garg, HP
    Kumar, A
    APPLIED THERMAL ENGINEERING, 2001, 21 (16) : 1699 - 1706
  • [23] Modification of a Solar Thermal Collector to Promote Heat Transfer inside an Evacuated Tube Solar Thermal Absorber
    Supankanok, Rasa
    Sriwong, Sukanpirom
    Ponpo, Phisan
    Wu, Wei
    Chandra-ambhorn, Walairat
    Anantpinijwatna, Amata
    APPLIED SCIENCES-BASEL, 2021, 11 (09):
  • [24] Solar thermal energy performance on mono/ trihybrid nanofluid flow through the evacuated thermal collector tube
    Rathore, Niraj
    Sandeep, N.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2023, 48 (94) : 36883 - 36899
  • [25] A novel thermal energy storage integrated evacuated tube heat pipe solar dryer for agricultural products: Performance and economic evaluation
    Mathew, Adarsh Abi
    Thangavel, Venugopal
    RENEWABLE ENERGY, 2021, 179 : 1674 - 1693
  • [26] Thermal performance of phase change material integrated heat pipe evacuated tube solar collector system: An experimental assessment
    Chopra, K.
    Pathak, Atin K.
    Tyagi, V. V.
    Pandey, A. K.
    Anand, Sanjeev
    Sari, Ahmet
    ENERGY CONVERSION AND MANAGEMENT, 2020, 203
  • [27] WATER DESALINATION BY EVACUATED TUBE HEAT PIPE SOLAR COLLECTOR
    Alwaer, A.
    Gryzagoridis, J.
    PROCEEDINGS OF THE 2014 11TH INTERNATIONAL CONFERENCE ON THE INDUSTRIAL AND COMMERCIAL USE OF ENERGY (ICUE), 2014, : 364 - 368
  • [28] Theoretical and experimental analysis of the thermal performance of a heat-pipe evacuated solar tube
    He, ZN
    HEAT TRANSFER SCIENCE AND TECHNOLOGY 2000, 2000, : 849 - 854
  • [29] Experimental analysis and thermal performance of evacuated tube solar collector assisted solar dryer
    Kushwah, Anand
    Kumar, Anil
    Pal, Amit
    Gaur, Manoj Kumar
    MATERIALS TODAY-PROCEEDINGS, 2021, 47 : 5846 - 5851
  • [30] Thermal Performance of Nanofluid Flow Inside Evacuated Tube Solar Collector
    Yazdi, Mohammad H.
    Solomin, Evgeny
    Fudholi, Ahmad
    Divandari, Ghasem
    Sopian, Kamanizzaman
    Chong, Perk Lin
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2021, 39 (04) : 1262 - 1270