Enhanced performance assessment of an integrated evacuated tube and flat plate collector solar air heater with thermal storage material

被引:19
|
作者
El-Fakharany, Magda K. [1 ]
Abo-Samra, Aly-Eldeen A. [1 ]
Abdelmaqsoud, A. M. [1 ]
Marzouk, S. A. [1 ]
机构
[1] Kafrelsheikh Univ, Fac Engn, Mech Engn Dept, Kafrelsheikh, Egypt
关键词
Solar air heater; Flat plate collector; PCM; Thermal efficacy; Evacuated tube;
D O I
10.1016/j.applthermaleng.2024.122653
中图分类号
O414.1 [热力学];
学科分类号
摘要
The solar air heater incorporating flat plate solar collectors is a straightforward system suitable for domestic use. Nonetheless, it faces challenges with lower thermal efficiency, especially when applied to moderate-temperature purposes. This study aimed to enhance the solar air heater performance by integrating an evacuated tube collector with a flat plate collector and incorporating paraffin C20-C33 as thermal storage material. Inside the flat plate solar collector, the phase change material (paraffin C20-C33) is placed under the absorber surface where the copper air pipes are immersed. Different parameters like outlet temperature, temperature rise, heat gain, thermal efficiency, and pressure drop have been analyzed and discussed for varying weather conditions and mass air flow rates. Also, the system performance is compared by using phase change material (paraffin C20-C33) and without it. The experimental results show that the innovative design achieves higher efficiency, temperature output, and operation hours compared to the standard SAHs. In the presented SAH, the maximum air outlet temperature reached 119 C at a flow rate of 0.015 kg/s. The maximum ratios of temperature rise to solar radiation at mass air flow rates 0.015, 0.02, and 0.025 kg/s were about 28 %, 26 %, and 25.5 % without PCM and 31 %, 28.5 %, and 27.6 % with PCM, respectively. The average daily thermal efficiency reached the highest values of 47.46 %, 56.12 %, and 64.53 % at air mass flow rates of 0.015, 0.02, and 0.025 kg/s respectively with PCM. The increase in the ratio of accumulated useful energy to average solar radiation through the day was found at 16 %, 14 %, and 13 % with PCM at 0.015, 0.02, and 0.025 kg/s respectively compared to the one without PCM. This developed solar air heater shows promising potential for various applications such as drying and industrial process heating.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Thermal performance of integrated collector storage solar air heater with evacuated tube and lap joint-type flat micro-heat pipe arrays
    Wang, Zeyu
    Diao, Yanhua
    Zhao, Yaohua
    Chen, Chuanqi
    Liang, Lin
    Wang, Tengyue
    APPLIED ENERGY, 2020, 261 (261)
  • [2] On the thermal performance of evacuated tube solar collector integrated with phase change material
    Olfian, Hassan
    Ajarostaghi, Seyed Soheil Mousavi
    Ebrahimnataj, Mohammadreza
    Farhadi, Mousa
    Arici, Muslum
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 53
  • [3] Evacuated tube solar thermal collector with enhanced phase change material thermal storage: An experimental study
    Senobar, Hossein
    Aramesh, Mohamad
    Shabani, Bahman
    JOURNAL OF ENERGY STORAGE, 2022, 46
  • [4] Performance investigation of flat plate solar collector with nanoparticle enhanced integrated thermal energy storage system
    Sharma, Harish Kumar
    Kumar, Satish
    Kumar, Shalendra
    Verma, Sujit Kumar
    JOURNAL OF ENERGY STORAGE, 2022, 55
  • [5] Experimental evaluation of a self storage integrated evacuated tube solar thermal collector
    Aramesh, Mohamad
    Shabani, Bahman
    JOURNAL OF ENERGY STORAGE, 2023, 62
  • [6] Thermal performance of phase change material integrated heat pipe evacuated tube solar collector system: An experimental assessment
    Chopra, K.
    Pathak, Atin K.
    Tyagi, V. V.
    Pandey, A. K.
    Anand, Sanjeev
    Sari, Ahmet
    ENERGY CONVERSION AND MANAGEMENT, 2020, 203
  • [7] Investigation of solar water heater by using flat plate collector and evacuated tubes
    Jayakanth, J. J.
    Ramasubramanian, S.
    Chandrasekaran, M.
    Manavalan, S.
    INTERNATIONAL CONFERENCE ON EMERGING TRENDS IN ENGINEERING RESEARCH, 2017, 183
  • [8] Thermal Performance Enhancement in Flat Plate Solar Collector Solar Water Heater: A Review
    Azha, Nurril Ikmal Shamsul
    Hussin, Hilmi
    Nasif, Mohammad Shakir
    Hussain, Tanweer
    PROCESSES, 2020, 8 (07)
  • [9] A comparative assessment of distributive mode active solar dryers: Flat plate collector vs evacuated tube collector with thermal energy storage and perforated baffled trays
    Sai Kandukuri, Krishna
    Kishor Sharma, Prashant
    Kumar Arun, Ravi
    Solar Energy, 2024, 271
  • [10] A comparative assessment of distributive mode active solar dryers: Flat plate collector vs evacuated tube collector with thermal energy storage and perforated baffled trays
    Kandukuri, Krishna Sai
    Sharma, Prashant Kishor
    Arun, Ravi Kumar
    SOLAR ENERGY, 2024, 271