AN EVALUATION OF THE SYSMEX NE-8000 HEMATOLOGY ANALYZER

被引:14
|
作者
HALLAWELL, R
OMALLEY, C
HUSSEIN, S
DAUER, RJ
TANTI, M
WOOTTON, AM
MCGRATH, KM
机构
[1] ROYAL MELBOURNE HOSP,DEPT DIAGNOST HEMATOL,C-RMH PO,PARKVILLE,VIC 3050,AUSTRALIA
[2] ROYAL MELBOURNE HOSP,DEPT BIOCHEM,PARKVILLE,VIC 3050,AUSTRALIA
关键词
AUTOMATED LEUKOCYTE 5-PART DIFFERENTIAL COUNT; SYSMEX NE-8000; COULTER COUNTER-S PLUS-IV; NCCLS REFERENCE DIFFERENTIAL METHOD;
D O I
10.1093/ajcp/96.5.594
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
The Sysmex NE-8000(R) is a new, fully automated hematology analyzer capable of providing a five-part white blood cell differential count and identifying abnormal specimens. This instrument was evaluated on 5,000 consecutive blood specimens and compared to the Coulter S Plus-IV(R) analyzer and manual differential cell counts to determine the efficacy of its five-cell differential and screening capabilities. There was a high correlation between the commercial counters for the standard parameters, white blood cell count, red blood cell count, hemoglobin level, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin concentration, and platelet count (r > 0.95), except for the mean corpuscular hemoglobin concentration (r = 0.51), for which the NE-8000 was considered the more accurate measurement. Precision and linearity studies were excellent. The white blood cell count, red blood cell count, hemoglobin level, and platelet count were reproducible on specimens stored at 4-degrees-C or room temperature for 72 hours and the differential counts were reproducible for 12 hours. The correlations between automated and manual counts for neutrophils, eosinophils, basophils, and lymphocytes were excellent: r = 0.912, 0.945, 0.332, and 0.964, respectively. The monocyte correlation improved with software modification from 0.306 to 0.801. The NE-8000 gave accurate and reproducible differential counts for neutrophils, lymphocytes, and monocytes on specimens with white blood cell counts as low as 0.6 X 10(9)/1. The ability of the instrument to 'flag' abnormal specimens was excellent. The false-positive rate on normal samples was 1.8%, and the false-negative rate on known abnormal samples was 0.3%, due only to nonrecognition of a mild left shift. The identification of specific abnormalities was less precise. The NE-8000 is a powerful hematology analyzer that can perform a five-part white blood cell differential count accurately for a wide range of WBCs and reliably indicate abnormal specimens. It is an excellent screening tool for distinguishing between normal and abnormal specimens and identifying those that require microscopy. Its reliability significantly reduces the need for manual film examination.
引用
收藏
页码:594 / 601
页数:8
相关论文
共 50 条
  • [31] Evaluation of bone marrow aspirates using the automated hematology analyzer Sysmex XN-3000
    Tsuchiya, Koji
    Kimura, Konobu
    Ai, Tomohiko
    Yamamoto, Takamasa
    Nagasaka, Kaori
    Takemura, Hiroyuki
    Edahiro, Yoko
    Saito, Kaori
    Horiuchi, Yuki
    Misawa, Shigeki
    Takaku, Tomoiku
    Ando, Jun
    Ando, Miki
    Miida, Takashi
    Uchihashi, Kinya
    Tabe, Yoko
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2023, 45 (04) : 460 - 468
  • [32] Performance evaluation of Hematology assays on Sysmex SE 950 analyzer using sigma-metrics
    Pilger, D.
    Berlitz, F. A.
    Fernandes, F.
    Silva, F.
    Garcia, S.
    Moreira, T.
    CLINICAL CHEMISTRY, 2006, 52 (06) : A28 - A28
  • [33] Performance evaluation of the new measurement channels on the automated Sysmex XN-9000 hematology analyzer
    Schapkaitz, E.
    Raburabu, S.
    CLINICAL BIOCHEMISTRY, 2018, 53 : 132 - 138
  • [34] PERFORMANCE EVALUATION OF THE WHITE CELL PRECURSOR CHANNEL ON THE SYSMEX XN-9000 HEMATOLOGY ANALYZER
    Schapkaitz, Elise
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2018, 40 : 128 - 128
  • [35] CLINICAL-EVALUATION OF THE TOA SYSMEX CC-800 8 PARAMETER HEMATOLOGY ANALYZER
    GIANDOMENICO, AR
    JOURNAL OF CLINICAL HEMATOLOGY AND ONCOLOGY, 1985, 15 (01): : 9 - 19
  • [36] Evaluating the Sysmex XE2100D Automated Hematology Analyzer
    Emery, R. L.
    Hammel, S.
    Gilles, E. J.
    Wendt, D. M.
    van Buskirk, C. M.
    Stubbs, J. R.
    TRANSFUSION, 2012, 52 : 107A - 107A
  • [37] Validation of the Sysmex XN-V hematology analyzer for feline specimens
    Guerlin, Maud
    Granat, Fanny
    Grebert, Margot
    Braun, Jean-Pierre
    Geffre, Anne
    Bourges-Abella, Nathalie
    Trumel, Catherine
    VETERINARY CLINICAL PATHOLOGY, 2024, 53 (03) : 294 - 308
  • [38] CELL POPULATION DATA OF AUTOMATED HEMATOLOGY ANALYZER SYSMEX XN FOR SEPSIS
    Park, Mikyoung
    Kim, Hanah
    Hur, Mina
    Chung, Hee-Jung
    Moon, Hee-Won
    Yun, Yeo-Min
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2019, 41 : 136 - 136
  • [39] Validation of the Sysmex XN-V hematology analyzer for canine specimens
    Grebert, Margot
    Granat, Fanny
    Braun, Jean-Pierre
    Leroy, Quentin
    Bourges-Abella, Nathalie
    Trumel, Catherine
    VETERINARY CLINICAL PATHOLOGY, 2021, 50 (02) : 184 - 197
  • [40] EVALUATION OF AUTOMATED HEMATOLOGY ANALYZER DYMIND DH76 COMPARED TO SYSMEX XN 1000 SYSTEM
    Velizarova, Milena
    Yacheva, Teodora
    Genova, Mariana
    Svinarov, Dobrin
    JOURNAL OF MEDICAL BIOCHEMISTRY, 2021, 40 (04) : 367 - 377