AN EVALUATION OF THE SYSMEX NE-8000 HEMATOLOGY ANALYZER

被引:14
|
作者
HALLAWELL, R
OMALLEY, C
HUSSEIN, S
DAUER, RJ
TANTI, M
WOOTTON, AM
MCGRATH, KM
机构
[1] ROYAL MELBOURNE HOSP,DEPT DIAGNOST HEMATOL,C-RMH PO,PARKVILLE,VIC 3050,AUSTRALIA
[2] ROYAL MELBOURNE HOSP,DEPT BIOCHEM,PARKVILLE,VIC 3050,AUSTRALIA
关键词
AUTOMATED LEUKOCYTE 5-PART DIFFERENTIAL COUNT; SYSMEX NE-8000; COULTER COUNTER-S PLUS-IV; NCCLS REFERENCE DIFFERENTIAL METHOD;
D O I
10.1093/ajcp/96.5.594
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
The Sysmex NE-8000(R) is a new, fully automated hematology analyzer capable of providing a five-part white blood cell differential count and identifying abnormal specimens. This instrument was evaluated on 5,000 consecutive blood specimens and compared to the Coulter S Plus-IV(R) analyzer and manual differential cell counts to determine the efficacy of its five-cell differential and screening capabilities. There was a high correlation between the commercial counters for the standard parameters, white blood cell count, red blood cell count, hemoglobin level, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin concentration, and platelet count (r > 0.95), except for the mean corpuscular hemoglobin concentration (r = 0.51), for which the NE-8000 was considered the more accurate measurement. Precision and linearity studies were excellent. The white blood cell count, red blood cell count, hemoglobin level, and platelet count were reproducible on specimens stored at 4-degrees-C or room temperature for 72 hours and the differential counts were reproducible for 12 hours. The correlations between automated and manual counts for neutrophils, eosinophils, basophils, and lymphocytes were excellent: r = 0.912, 0.945, 0.332, and 0.964, respectively. The monocyte correlation improved with software modification from 0.306 to 0.801. The NE-8000 gave accurate and reproducible differential counts for neutrophils, lymphocytes, and monocytes on specimens with white blood cell counts as low as 0.6 X 10(9)/1. The ability of the instrument to 'flag' abnormal specimens was excellent. The false-positive rate on normal samples was 1.8%, and the false-negative rate on known abnormal samples was 0.3%, due only to nonrecognition of a mild left shift. The identification of specific abnormalities was less precise. The NE-8000 is a powerful hematology analyzer that can perform a five-part white blood cell differential count accurately for a wide range of WBCs and reliably indicate abnormal specimens. It is an excellent screening tool for distinguishing between normal and abnormal specimens and identifying those that require microscopy. Its reliability significantly reduces the need for manual film examination.
引用
收藏
页码:594 / 601
页数:8
相关论文
共 50 条
  • [21] Evaluation of the Flagging Performance of the Hematology Analyzer Sysmex XN Series on the Basis of "Q Values''
    Kweon, Oh Joo
    Lee, Mi-Kyung
    Kim, Hye Ryoun
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2018, 142 (01) : 83 - 88
  • [22] Evaluation of immature granulocyte parameters in myeloid neoplasms assayed by Sysmex XN hematology analyzer
    Qifeng Lu
    Ying Li
    Tian Li
    Tingting Hou
    Yajuan Zhao
    Shu Feng
    Xixian Yang
    Mengyu Zhu
    Yajuan Shen
    Journal of Hematopathology, 2022, 15 : 1 - 6
  • [23] EVALUATION OF FLAGGING PERFORMANCE OF THE HEMATOLOGY ANALYZER SYSMEX XN SERIES ON THE BASIS OF "Q VALUES"
    Kim, Hye Ryoun
    Kweon, Oh Joo
    Cho, Sung Ran
    Ahn, Jeong-Yeal
    Moon, Yeonsook
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2017, 39 : 56 - 56
  • [24] Performance evaluation of recently launched Sysmex XN-550 Automatic Hematology Analyzer
    Jo, S. Y.
    Park, S. H.
    Kim, I. -S.
    Yi, J.
    Kim, H. -H.
    Chang, C. L.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2017, 39 (01) : E4 - E9
  • [25] Performance evaluation of Sysmex XN hematology analyzer in umbilical cord blood: a comparison study with Sysmex XE-2100
    Kim, Hanah
    Hur, Mina
    Choi, Sang-Gyeu
    Moon, Hee-Won
    Yun, Yeo-Min
    Hwang, Han Sung
    Kwon, Han Sung
    Sohn, In Sook
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2014, 52 (12) : 1771 - 1779
  • [26] A data management software for the Sysmex NE 8000 haematology analyser
    Cambus, JP
    Nguyen, F
    Cambus, F
    COMPUTERS IN BIOLOGY AND MEDICINE, 1996, 26 (04) : 355 - 359
  • [27] Clinical case: Malaria detection by the Sysmex XN hematology analyzer
    Thomlimson, L.
    Ortega, N.
    Samaniego, L.
    Calvo, A.
    Martin, S.
    CLINICA CHIMICA ACTA, 2019, 493 : S256 - S256
  • [28] Performance evaluation of the white cell precursor channel on the Sysmex XN hematology analyzer in HIV specimens
    Schapkaitz, Elise
    Khoza, Phoyisile
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2018, 32 (04)
  • [29] PERFORMANCE EVALUATION OF THE NEW MEASUREMENT CHANNELS ON THE AUTOMATED SYSMEX XN-9000 HEMATOLOGY ANALYZER
    Schapkaitz, Elise
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2018, 40 : 127 - 127
  • [30] Evaluation of the performance of sysmex XN-3100 automated hematology analyzer regarding the sysmex XE-2100 and microscopic examination
    Incir, Said
    Palaoglu, Kerim Erhan
    TURKISH JOURNAL OF BIOCHEMISTRY-TURK BIYOKIMYA DERGISI, 2021, 46 (01): : 27 - 35