AN EVALUATION OF THE SYSMEX NE-8000 HEMATOLOGY ANALYZER

被引:14
|
作者
HALLAWELL, R
OMALLEY, C
HUSSEIN, S
DAUER, RJ
TANTI, M
WOOTTON, AM
MCGRATH, KM
机构
[1] ROYAL MELBOURNE HOSP,DEPT DIAGNOST HEMATOL,C-RMH PO,PARKVILLE,VIC 3050,AUSTRALIA
[2] ROYAL MELBOURNE HOSP,DEPT BIOCHEM,PARKVILLE,VIC 3050,AUSTRALIA
关键词
AUTOMATED LEUKOCYTE 5-PART DIFFERENTIAL COUNT; SYSMEX NE-8000; COULTER COUNTER-S PLUS-IV; NCCLS REFERENCE DIFFERENTIAL METHOD;
D O I
10.1093/ajcp/96.5.594
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
The Sysmex NE-8000(R) is a new, fully automated hematology analyzer capable of providing a five-part white blood cell differential count and identifying abnormal specimens. This instrument was evaluated on 5,000 consecutive blood specimens and compared to the Coulter S Plus-IV(R) analyzer and manual differential cell counts to determine the efficacy of its five-cell differential and screening capabilities. There was a high correlation between the commercial counters for the standard parameters, white blood cell count, red blood cell count, hemoglobin level, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin concentration, and platelet count (r > 0.95), except for the mean corpuscular hemoglobin concentration (r = 0.51), for which the NE-8000 was considered the more accurate measurement. Precision and linearity studies were excellent. The white blood cell count, red blood cell count, hemoglobin level, and platelet count were reproducible on specimens stored at 4-degrees-C or room temperature for 72 hours and the differential counts were reproducible for 12 hours. The correlations between automated and manual counts for neutrophils, eosinophils, basophils, and lymphocytes were excellent: r = 0.912, 0.945, 0.332, and 0.964, respectively. The monocyte correlation improved with software modification from 0.306 to 0.801. The NE-8000 gave accurate and reproducible differential counts for neutrophils, lymphocytes, and monocytes on specimens with white blood cell counts as low as 0.6 X 10(9)/1. The ability of the instrument to 'flag' abnormal specimens was excellent. The false-positive rate on normal samples was 1.8%, and the false-negative rate on known abnormal samples was 0.3%, due only to nonrecognition of a mild left shift. The identification of specific abnormalities was less precise. The NE-8000 is a powerful hematology analyzer that can perform a five-part white blood cell differential count accurately for a wide range of WBCs and reliably indicate abnormal specimens. It is an excellent screening tool for distinguishing between normal and abnormal specimens and identifying those that require microscopy. Its reliability significantly reduces the need for manual film examination.
引用
收藏
页码:594 / 601
页数:8
相关论文
共 50 条
  • [41] Biological variation of platelet parameters determined by the Sysmex XN hematology analyzer
    Buoro, Sabrina
    Seghezzi, Michela
    Manenti, Barbara
    Pacioni, Aurelio
    Carobene, Anna
    Ceriotti, Ferruccio
    Ottomano, Cosimo
    Lippi, Giuseppe
    CLINICA CHIMICA ACTA, 2017, 470 : 125 - 132
  • [42] COMPARATIVE-STUDY OF THE DIFFERENTIAL WHITE BLOOD-CELL COUNT USING 3 AUTOMATED ANALYZERS - COULTER STKS, SYSMEX NE-8000 AND TECHNICON H-1
    LESESVE, JF
    LACOMBE, F
    BOISSEAU, MR
    BERNARD, P
    ANNALES DE BIOLOGIE CLINIQUE, 1994, 52 (04) : 295 - 297
  • [43] Performance evaluation of the digital cell imaging analyzer DI-60 integrated into the fully automated Sysmex XN hematology analyzer system
    Tabe, Yoko
    Yamamoto, Takemasa
    Maenou, Imiko
    Nakai, Rie
    Idei, Mayumi
    Horii, Takashi
    Miida, Takashi
    Ohsaka, Akimichi
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2015, 53 (02) : 281 - 289
  • [44] Evaluation the diagnostic performance of immature granulocyte cells flag on automated hematology analyzer sysmex XN-series
    Chieh-Hsi, W.
    Fang-Yu, W.
    Hsiang-Ling, H.
    CLINICA CHIMICA ACTA, 2022, 530 : S187 - S187
  • [45] PERFORMANCE EVALUATION OF THE HEMATOLOGY ANALYZER SYSMEX XE-5000 FOR WHITE BLOOD CELL ANALYSIS IN CEREBROSPINAL FLUID
    Perne, Andrea
    Hainfellner, Johannes A.
    Szekeres, Thomas
    Schwarzinger, Ilse
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S770 - S770
  • [46] Screening for hematopoietic progenitor cells by the Sysmex SE-9000 hematology analyzer
    Houwen, B
    Wang, FS
    Stewart, N
    BRITISH JOURNAL OF HAEMATOLOGY, 1998, 102 (01) : 76 - 76
  • [47] EVALUATION OF A NEW METHOD FOR THE ENUMERATION OF NUCLEATED RED BLOOD CELLS ON THE NEW SYSMEX XN™ AUTOMATED HEMATOLOGY ANALYZER
    Rosenthal, Nancy
    Brown, Bonnie
    Connell, Barbara
    Kruger, Julie
    Capper, Mary
    Blaine, Kimberly
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2012, 34 : 131 - 131
  • [48] Measurement uncertainty of platelet concentration using the Sysmex XN automated hematology analyzer
    Lim, Yong Kwan
    Kweon, Oh Joo
    Choi, Jee-Hye
    Lee, Woonhyoung
    Park, Ae Ja
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2018, 78 (03): : 224 - 229
  • [49] Design of Malaria Diagnostic Criteria for the Sysmex XE-2100 Hematology Analyzer
    Campuzano-Zuluaga, German
    Alvarez-Sanchez, Gonzalo
    Elcy Escobar-Gallo, Gloria
    Marina Valencia-Zuluaga, Luz
    Marcela Rios-Orrego, Alexandra
    Pabon-Vidal, Adriana
    Felipe Miranda-Arboleda, Andres
    Blair-Trujillo, Silvia
    Campuzano-Maya, German
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2010, 82 (03): : 402 - 411
  • [50] Performance Evaluation of the Sysmex XE-5000 Hematology Analyzer for White Blood Cell Analysis in Cerebrospinal Fluid
    Perne, Andrea
    Hainfellner, Johannes A.
    Womastek, Irene
    Haushofer, Alexander
    Szekeres, Thomas
    Schwarzinger, Ilse
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2012, 136 (02) : 194 - 198