Validation of the Sysmex XN-V hematology analyzer for feline specimens
被引:2
|作者:
Guerlin, Maud
[1
,2
]
Granat, Fanny
[1
,3
]
Grebert, Margot
[1
,2
]
Braun, Jean-Pierre
[4
]
Geffre, Anne
[1
,2
]
Bourges-Abella, Nathalie
[2
]
Trumel, Catherine
[1
,2
]
机构:
[1] Univ Toulouse, Dept Sci Clin Anim Co & Sport, ENVT, Toulouse, France
[2] Univ Toulouse, CREFRE, INSERM, ENVT,UPS, Toulouse, France
[3] Univ Toulouse, CRCT, INSERM, UMR 1037,ENVT, Toulouse, France
[4] Anim & Comparat Clin Pathol, Toulouse, France
关键词:
blood;
cat;
comparison study;
method validation;
platelet clumping;
REFERENCE INTERVALS;
ADVIA(R) 2120;
XT-2000IV;
CATS;
DOGS;
ACCURACY;
CANINE;
SYSTEM;
COUNT;
D O I:
10.1111/vcp.13377
中图分类号:
S85 [动物医学(兽医学)];
学科分类号:
0906 ;
摘要:
Background: The Sysmex XN- V is derived from the new Sysmex XN series of human hematology analyzers. The main changes from the previously validated XT- 2000iV analyzer include an optic- fluorescent analysis for platelets and a nucleated red blood cell (NRBC) count. Objective: We aimed to validate the Sysmex XN- V for feline blood following the American College for Veterinary Clinical Pathology and International Council for Standardization in Hematology recommendations. Methods: Feline EDTA blood specimens were analyzed on the Sysmex XN- V to evaluate repeatability, linearity, comparison with the XT- 2000iV analyzer and manual methods, stability, and to verify the previously established Sysmex XT- 2000iV RIs. Results: Repeatability was excellent for most variables. Visually determined linearity was excellent or good for most variables except eosinophils and platelet variables. The correlation between the XN- V and XT- 2000iV analyzers was good (>= 0.82) for all variables except reticulocyte indices. Correlations between the Sysmex XN- V and manual differential counts were good to excellent for most variables, acceptable for neutrophils, and fair for monocytes and NRBC. The previously established Sysmex XT- 2000iV RIs can be used to interpret results from the Sysmex XN- V analyzer for most variables except red cell distribution width and reticulocyte variables. The RI for platelet variables could not be evaluated because of platelet clumps. Changes in the Sysmex XN- V measurements after storage at 4 and 24 degrees C were similar to those described for the Sysmex XT- 2000iV analyzer. Conclusions: The performance of the Sysmex XN- V analyzer was good and compared favorably with the Sysmex XT- 2000iV analyzer.