Validation of the Sysmex XN-V hematology analyzer for feline specimens

被引:2
|
作者
Guerlin, Maud [1 ,2 ]
Granat, Fanny [1 ,3 ]
Grebert, Margot [1 ,2 ]
Braun, Jean-Pierre [4 ]
Geffre, Anne [1 ,2 ]
Bourges-Abella, Nathalie [2 ]
Trumel, Catherine [1 ,2 ]
机构
[1] Univ Toulouse, Dept Sci Clin Anim Co & Sport, ENVT, Toulouse, France
[2] Univ Toulouse, CREFRE, INSERM, ENVT,UPS, Toulouse, France
[3] Univ Toulouse, CRCT, INSERM, UMR 1037,ENVT, Toulouse, France
[4] Anim & Comparat Clin Pathol, Toulouse, France
关键词
blood; cat; comparison study; method validation; platelet clumping; REFERENCE INTERVALS; ADVIA(R) 2120; XT-2000IV; CATS; DOGS; ACCURACY; CANINE; SYSTEM; COUNT;
D O I
10.1111/vcp.13377
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background: The Sysmex XN- V is derived from the new Sysmex XN series of human hematology analyzers. The main changes from the previously validated XT- 2000iV analyzer include an optic- fluorescent analysis for platelets and a nucleated red blood cell (NRBC) count. Objective: We aimed to validate the Sysmex XN- V for feline blood following the American College for Veterinary Clinical Pathology and International Council for Standardization in Hematology recommendations. Methods: Feline EDTA blood specimens were analyzed on the Sysmex XN- V to evaluate repeatability, linearity, comparison with the XT- 2000iV analyzer and manual methods, stability, and to verify the previously established Sysmex XT- 2000iV RIs. Results: Repeatability was excellent for most variables. Visually determined linearity was excellent or good for most variables except eosinophils and platelet variables. The correlation between the XN- V and XT- 2000iV analyzers was good (>= 0.82) for all variables except reticulocyte indices. Correlations between the Sysmex XN- V and manual differential counts were good to excellent for most variables, acceptable for neutrophils, and fair for monocytes and NRBC. The previously established Sysmex XT- 2000iV RIs can be used to interpret results from the Sysmex XN- V analyzer for most variables except red cell distribution width and reticulocyte variables. The RI for platelet variables could not be evaluated because of platelet clumps. Changes in the Sysmex XN- V measurements after storage at 4 and 24 degrees C were similar to those described for the Sysmex XT- 2000iV analyzer. Conclusions: The performance of the Sysmex XN- V analyzer was good and compared favorably with the Sysmex XT- 2000iV analyzer.
引用
收藏
页码:294 / 308
页数:15
相关论文
共 50 条
  • [21] Performance of the Sysmex XN-V body fluid module for canine cerebrospinal fluid cell count
    Ortiz-Nisa, Sonia
    Sanz, Alba
    Pastor, Josep
    De la Fuente, Cristian
    Anor, Sonia
    VETERINARY CLINICAL PATHOLOGY, 2021, 50 (03) : 359 - 368
  • [22] PERFORMANCE EVALUATION OF Q-FLAG OF HEMATOLOGY ANALYZER, SYSMEX XN-20
    Kim, H. R.
    Kweon, O. J.
    HAEMATOLOGICA, 2016, 101 : 749 - 749
  • [23] Evaluation of immature granulocyte parameters in myeloid neoplasms assayed by Sysmex XN hematology analyzer
    Lu, Qifeng
    Li, Ying
    Li, Tian
    Hou, Tingting
    Zhao, Yajuan
    Feng, Shu
    Yang, Xixian
    Zhu, Mengyu
    Shen, Yajuan
    JOURNAL OF HEMATOPATHOLOGY, 2022, 15 (01) : 1 - 6
  • [24] Evaluation of the Flagging Performance of the Hematology Analyzer Sysmex XN Series on the Basis of "Q Values''
    Kweon, Oh Joo
    Lee, Mi-Kyung
    Kim, Hye Ryoun
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2018, 142 (01) : 83 - 88
  • [25] Evaluation of immature granulocyte parameters in myeloid neoplasms assayed by Sysmex XN hematology analyzer
    Qifeng Lu
    Ying Li
    Tian Li
    Tingting Hou
    Yajuan Zhao
    Shu Feng
    Xixian Yang
    Mengyu Zhu
    Yajuan Shen
    Journal of Hematopathology, 2022, 15 : 1 - 6
  • [26] Clinical value of smear review of flagged samples analyzed with the Sysmex XN hematology analyzer
    Winther-Larsen, Anne
    Vestergaard, Else Marie
    Abildgaard, Anders
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2025, 63 (03) : 636 - 644
  • [27] EVALUATION OF FLAGGING PERFORMANCE OF THE HEMATOLOGY ANALYZER SYSMEX XN SERIES ON THE BASIS OF "Q VALUES"
    Kim, Hye Ryoun
    Kweon, Oh Joo
    Cho, Sung Ran
    Ahn, Jeong-Yeal
    Moon, Yeonsook
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2017, 39 : 56 - 56
  • [28] Performance evaluation of recently launched Sysmex XN-550 Automatic Hematology Analyzer
    Jo, S. Y.
    Park, S. H.
    Kim, I. -S.
    Yi, J.
    Kim, H. -H.
    Chang, C. L.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2017, 39 (01) : E4 - E9
  • [29] Reference interval for immature platelet fraction on Sysmex XN hematology analyzer: a comparison study with Sysmex XE-2100
    Ko, Young Jin
    Hur, Mina
    Kim, Hanah
    Choi, Sang Gyeu
    Moon, Hee-Won
    Yun, Yeo-Min
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2015, 53 (07) : 1091 - 1097
  • [30] Performance evaluation of Sysmex XN hematology analyzer in umbilical cord blood: a comparison study with Sysmex XE-2100
    Kim, Hanah
    Hur, Mina
    Choi, Sang-Gyeu
    Moon, Hee-Won
    Yun, Yeo-Min
    Hwang, Han Sung
    Kwon, Han Sung
    Sohn, In Sook
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2014, 52 (12) : 1771 - 1779