A comparison of i-gel(TM) and LMA Supreme(TM) in anesthetized and paralyzed children

被引:16
|
作者
Kim, Hyuk [1 ]
Lee, Ji Yeon [1 ]
Lee, Seung Yoon [1 ]
Park, Sang Yoong [1 ]
Lee, Seung Cheol [1 ]
Chung, Chan Jong [1 ]
机构
[1] Dong A Univ Hosp, Dept Anesthesiol & Pain Med, Busan, South Korea
关键词
Laryngeal masks; Pediatrics;
D O I
10.4097/kjae.2014.67.5.317
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Both the i-gel(TM) (i-gel) and LMA Supreme(TM) (Supreme) are new single-use second generation supraglottic airway devices available in pediatric sizes. This study was designed to investigate the i-gel in comparison with the Supreme in children undergoing general anesthesia. Methods: One hundred children with American Society of Anesthesiologists physical status I or II undergoing general anesthesia were randomly assigned to either the i-gel or the Supreme group (50 children in each group). The device size was chosen according to weight of the children. We assessed the insertion success rate, insertion time, oropharyngeal leak pressure, grade of the fiberoptic glottic view, number of airway manipulations required, and postoperative complications. Results: There were no differences in the demographic data between the two groups. The success rate of insertion was same in both groups. The insertion time of the i-gel was longer than that of Supreme (P = 0.004). The oropharyngeal leak pressure in the i-gel group was higher than that in the Supreme group (P = 0.013). On fiberoptic examination, the vocal cords were visible in 90% of the children in the i-gel group and in 96% of the children in the Supreme group. The number of airway manipulations required was higher in the i-gel group (14 cases) than in the Supreme group (1 case) (P < 0.001). There were no differences in complications including blood staining of the device and sore throat between both groups. Conclusions: Both the i-gel and Supreme provided a satisfactory airway during general anesthesia in children. Compared to the Supreme, the i-gel demonstrated a higher oropharyngeal leak pressure, longer time for insertion, and a greater number of airway manipulations during anesthesia.
引用
收藏
页码:317 / 322
页数:6
相关论文
共 50 条
  • [31] LMA Supreme (TM): New design or a pig in a poke?
    Lopez, A. M.
    Valero, R.
    Lopez, S.
    Zaballos, M.
    Garcia, M. L.
    REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2013, 60 (10): : 597 - 598
  • [32] Clinical Performance Comparison of LMA Protector™ Cuff Pilot™ and LMA Supreme™ When Used in Anesthetized, Non-paralyzed Patients
    Chan, Weng Ken
    Liu, Chian Yong
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (03)
  • [33] Crossover Comparison of the Laryngeal Mask Supreme™ and the i-gel™ in Simulated Difficult Airway Scenario in Anesthetized Patients
    Theiler, Lorenz G.
    Kleine-Brueggeney, Maren
    Kaiser, Dagmar
    Urwyler, Natalie
    Luyet, Cedric
    Vogt, Andreas
    Greif, Robert
    Unibe, M. M. E.
    ANESTHESIOLOGY, 2009, 111 (01) : 55 - 62
  • [34] Comparison of the Proseal LMA and intersurgical I-gel during gynecological laparoscopy
    Jeon, Woo Jae
    Cho, Sang Yun
    Baek, Seong Jin
    Kim, Kyoung Hun
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2012, 63 (06) : 510 - 514
  • [35] Effects of Supraglottic Airway Devices on Hemodynamic Response and Optic Nerve Sheath Diameter: Proseal LMA, LMA Supreme, and I-gel LMA
    Okyay, Rahsan Dilek
    Kucukosman, Gamze
    Koksal, Bengu Gulhan
    Piskin, Ozcan
    Ayoglu, Hilal
    MEDICINA-LITHUANIA, 2023, 59 (04):
  • [36] A case of breakage of LMA Supreme (TM) on its first use
    Simon, Binu Puthur
    INDIAN JOURNAL OF ANAESTHESIA, 2011, 55 (06) : 635 - +
  • [37] Application of the LMA-Supreme™ and i-gel™ laryngeal masks during pelvic operations in adults
    Wang, Fei
    Zhang, Rui
    ASIAN JOURNAL OF SURGERY, 2016, 39 (01) : 1 - 5
  • [38] Randomized prospective trial comparing two supraglottic airway devices: i-gel™ and LMA-Supreme™ in paralyzed patients [Étude prospective randomisée comparant deux dispositifs pour voie aérienne supraglottique: i-gel™ et LMA-Supreme™ chez des patients paralysés]
    Joly N.
    Poulin L.-P.
    Tanoubi I.
    Drolet P.
    Donati F.
    St-Pierre P.
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2014, 61 (9): : 794 - 800
  • [39] Comparison of Proseal LMA with i-Gel in children under controlled ventilation: a prospective randomised clinical study
    Shiveshi, Praveen
    Anandaswamy, Tejesh Channasandra
    BRAZILIAN JOURNAL OF ANESTHESIOLOGY, 2022, 72 (02): : 247 - 252
  • [40] A study to evaluate fibreoptic-guided intubation through the i-gel (TM)
    Taxak, S.
    Vashisht, K.
    Kaur, K. P.
    Ahlawat, G.
    Bhardwaj, M.
    SOUTHERN AFRICAN JOURNAL OF ANAESTHESIA AND ANALGESIA, 2013, 19 (02) : 120 - 123