A comparison of i-gel(TM) and LMA Supreme(TM) in anesthetized and paralyzed children

被引:16
|
作者
Kim, Hyuk [1 ]
Lee, Ji Yeon [1 ]
Lee, Seung Yoon [1 ]
Park, Sang Yoong [1 ]
Lee, Seung Cheol [1 ]
Chung, Chan Jong [1 ]
机构
[1] Dong A Univ Hosp, Dept Anesthesiol & Pain Med, Busan, South Korea
关键词
Laryngeal masks; Pediatrics;
D O I
10.4097/kjae.2014.67.5.317
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Both the i-gel(TM) (i-gel) and LMA Supreme(TM) (Supreme) are new single-use second generation supraglottic airway devices available in pediatric sizes. This study was designed to investigate the i-gel in comparison with the Supreme in children undergoing general anesthesia. Methods: One hundred children with American Society of Anesthesiologists physical status I or II undergoing general anesthesia were randomly assigned to either the i-gel or the Supreme group (50 children in each group). The device size was chosen according to weight of the children. We assessed the insertion success rate, insertion time, oropharyngeal leak pressure, grade of the fiberoptic glottic view, number of airway manipulations required, and postoperative complications. Results: There were no differences in the demographic data between the two groups. The success rate of insertion was same in both groups. The insertion time of the i-gel was longer than that of Supreme (P = 0.004). The oropharyngeal leak pressure in the i-gel group was higher than that in the Supreme group (P = 0.013). On fiberoptic examination, the vocal cords were visible in 90% of the children in the i-gel group and in 96% of the children in the Supreme group. The number of airway manipulations required was higher in the i-gel group (14 cases) than in the Supreme group (1 case) (P < 0.001). There were no differences in complications including blood staining of the device and sore throat between both groups. Conclusions: Both the i-gel and Supreme provided a satisfactory airway during general anesthesia in children. Compared to the Supreme, the i-gel demonstrated a higher oropharyngeal leak pressure, longer time for insertion, and a greater number of airway manipulations during anesthesia.
引用
收藏
页码:317 / 322
页数:6
相关论文
共 50 条
  • [41] Comparison of I-gel and LMA Protector in Laparoscopic Cholecystectomy: A Randomized Controlled Trial
    Ari, D. E.
    Abitagaoglu, S.
    Koksal, C.
    YildirimAr, A.
    Emrem, D.
    Ustun, M.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2022, 25 (01) : 90 - 96
  • [42] A comparison of the i-gel and classic LMA insertion in manikins by experienced and novice physicians
    Stroumpoulis, Konstantinos
    Isaia, Christina
    Bassiakou, Eleni
    Pantazopoulos, Ioannis
    Troupis, Georgios
    Mazarakis, Antonios
    Demestiha, Theano
    Xanthos, Theodoros
    EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2012, 19 (01) : 24 - 27
  • [43] Self-knotting of a nasogastric tube passed through i-gel (TM)
    Garg, Shaloo
    Kapoor, Mukul Chandra
    INDIAN JOURNAL OF ANAESTHESIA, 2015, 59 (05) : 331 - 332
  • [44] A COMPARISON BETWEEN I-GEL AND THE LMA CLASSIC IN SPONTANEOUSLY VENTILATING ANAESTHETISED PATIENTS
    Arora, Vishal
    Fotedar, Shivani
    Khan, Mohd. Zafeer
    Awasthi, Gunjan
    Arya, Arvind Kumar
    Singh, Vivek
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2018, 7 (08): : 1034 - 1039
  • [45] Application of PEEP using the i-gel during volume-controlled ventilation in anesthetized, paralyzed patients
    Yong Beom Kim
    Young Jin Chang
    Wol Seon Jung
    Sang Ho Byen
    Youn Yi Jo
    Journal of Anesthesia, 2013, 27 : 827 - 831
  • [46] Application of PEEP using the i-gel during volume-controlled ventilation in anesthetized, paralyzed patients
    Kim, Yong Beom
    Chang, Young Jin
    Jung, Wol Seon
    Byen, Sang Ho
    Jo, Youn Yi
    JOURNAL OF ANESTHESIA, 2013, 27 (06) : 827 - 831
  • [47] A randomised comparison of the LMA Supreme™ and LMA ProSeal™ in children
    Jagannathan, N.
    Sohn, L. E.
    Sawardekar, A.
    Gordon, J.
    Langen, K. E.
    Anderson, K.
    ANAESTHESIA, 2012, 67 (06) : 632 - 639
  • [48] A RANDOMIZED COMPARISON OF I-GEL AND AMBU AURAGAIN TM LARYNGEAL MASK AIRWAY IN PATIENTS WITH SIMULATED CERVICAL IMMOBILIZATION
    Hur, Min
    Kim, Tae Kyong
    Lee, Hyung-Chul
    ANESTHESIA AND ANALGESIA, 2019, 128 : 17 - 20
  • [49] Randomized comparison of the i-gel™, the LMA Supreme™, and the Laryngeal Tube Suction-D using clinical and fibreoptic assessments in elective patients
    Sebastian G Russo
    Stephan Cremer
    Tamara Galli
    Christoph Eich
    Anselm Bräuer
    Thomas A Crozier
    Martin Bauer
    Micha Strack
    BMC Anesthesiology, 12
  • [50] Comparison of the I-gel Laryngeal Mask Airway With the LMA-Supreme for Airway Management in Patients Undergoing Elective Lumbar Vertebral Surgery
    Kang, Fang
    Li, Juan
    Chai, XiaoQing
    Yu, JinGui
    Zhang, HuaMing
    Tang, ChaoLiang
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2015, 27 (01) : 37 - 41