A comparison of i-gel(TM) and LMA Supreme(TM) in anesthetized and paralyzed children

被引:16
|
作者
Kim, Hyuk [1 ]
Lee, Ji Yeon [1 ]
Lee, Seung Yoon [1 ]
Park, Sang Yoong [1 ]
Lee, Seung Cheol [1 ]
Chung, Chan Jong [1 ]
机构
[1] Dong A Univ Hosp, Dept Anesthesiol & Pain Med, Busan, South Korea
关键词
Laryngeal masks; Pediatrics;
D O I
10.4097/kjae.2014.67.5.317
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Both the i-gel(TM) (i-gel) and LMA Supreme(TM) (Supreme) are new single-use second generation supraglottic airway devices available in pediatric sizes. This study was designed to investigate the i-gel in comparison with the Supreme in children undergoing general anesthesia. Methods: One hundred children with American Society of Anesthesiologists physical status I or II undergoing general anesthesia were randomly assigned to either the i-gel or the Supreme group (50 children in each group). The device size was chosen according to weight of the children. We assessed the insertion success rate, insertion time, oropharyngeal leak pressure, grade of the fiberoptic glottic view, number of airway manipulations required, and postoperative complications. Results: There were no differences in the demographic data between the two groups. The success rate of insertion was same in both groups. The insertion time of the i-gel was longer than that of Supreme (P = 0.004). The oropharyngeal leak pressure in the i-gel group was higher than that in the Supreme group (P = 0.013). On fiberoptic examination, the vocal cords were visible in 90% of the children in the i-gel group and in 96% of the children in the Supreme group. The number of airway manipulations required was higher in the i-gel group (14 cases) than in the Supreme group (1 case) (P < 0.001). There were no differences in complications including blood staining of the device and sore throat between both groups. Conclusions: Both the i-gel and Supreme provided a satisfactory airway during general anesthesia in children. Compared to the Supreme, the i-gel demonstrated a higher oropharyngeal leak pressure, longer time for insertion, and a greater number of airway manipulations during anesthesia.
引用
收藏
页码:317 / 322
页数:6
相关论文
共 50 条
  • [21] Randomized prospective trial comparing two supraglottic airway devices: I-gel™ and LMA-Supreme™ in paralyzed patients
    Poulin, L-P
    Joly, N.
    Tanoubi, I
    Drolet, P.
    Donati, F.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2014, 31 : 280 - 280
  • [22] CONTRAST OF I-GEL TM IN ADDITION LMA PROS PAL TM IN SEDATED RESPONDENTS EXPERIENCING LAPAROSCOPIC CHOLECYSTECTOMY: THE POTENTIAL AND RANDOMIZED MEDICAL TEST
    Azhar, Amina
    Ahmad, Bilal
    Amin, Fatima
    Gill, Hafiz Ali Raza
    INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2019, 6 (06): : 12557 - 12560
  • [23] The LMA-Supreme versus the I-gel in simulated difficult airway in children A randomised study
    Kus, Alparslan
    Gok, Cigdem N.
    Hosten, Tulay
    Gurkan, Yavuz
    Solak, Mine
    Toker, Kamil
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2014, 31 (05) : 280 - 284
  • [24] Comparison of Laryngeal Mask Supreme™ and i-gel™ in simulated difficult airway in anesthetized patients
    Theiler, L.
    Kleine-Brueggeney, M.
    Urwyler, N.
    Luyet, C.
    Kaiser, D.
    Greif, R.
    SWISS MEDICAL WEEKLY, 2008, 138 (41-42) : 7S - 7S
  • [25] Use of supraglottic devices with drainage channel in laparoscopic cholecystectomy: a prospective, randomized comparison of LMA Proseal™, LMA Supreme™ and i-gel™
    Belena, J. M.
    Nunez, M.
    Gasco, C.
    Vidal, A.
    Alcojor, A.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2014, 31 : 281 - 281
  • [26] Comparison of LMA Classic and i-gel in anesthetized, spontaneously breathing patients during elective surgical procedures
    Durrani, Haq Dad
    Butt, Khalid Javed
    Sadaf, Sairah
    Rehan, Anwer
    Khan, Abdul Majid
    Umar, Alina
    ANAESTHESIA PAIN & INTENSIVE CARE, 2013, 17 (03) : 274 - 278
  • [27] Comparison of guided insertion of the LMA ProSeal™ vs the i-gel™
    Gasteiger, L.
    Brimacombe, J.
    Perkhofer, D.
    Kaufmann, M.
    Keller, C.
    ANAESTHESIA, 2010, 65 (09) : 913 - 916
  • [28] A comparison of supraglottic airway i-gel (TM) vs. classic laryngeal mask airway in small children
    Lee, Ju-Hyun
    Cho, Hyun-Seok
    Shin, Won-Jung
    Yang, Hong-Seuk
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2014, 66 (02) : 127 - 130
  • [29] Comparison of i-gel, LMA-supreme, LMA-classic and LMA-proseal as conduits of endotracheal intubation in newborns and infants: A manikin study
    Ankay-Yilbas, Aysun
    Basaran, Betul
    Uzumcugil, Filiz
    Akca, Basak
    Izgi, Murat
    Canbay, Ozgur
    TURKISH JOURNAL OF PEDIATRICS, 2019, 61 (02) : 166 - 173
  • [30] Comparison of the LMA Supreme vs the i-gel™ in paralysed patients undergoing gynaecological laparoscopic surgery with controlled ventilation
    Teoh, W. H. L.
    Lee, K. M.
    Suhitharan, T.
    Yahaya, Z.
    Teo, M. M.
    Sia, A. T. H.
    ANAESTHESIA, 2010, 65 (12) : 1173 - 1179