Effects of Supraglottic Airway Devices on Hemodynamic Response and Optic Nerve Sheath Diameter: Proseal LMA, LMA Supreme, and I-gel LMA

被引:1
|
作者
Okyay, Rahsan Dilek [1 ]
Kucukosman, Gamze [1 ]
Koksal, Bengu Gulhan [1 ]
Piskin, Ozcan [1 ]
Ayoglu, Hilal [1 ]
机构
[1] Zonguldak Bulent Ecevit Univ, Fac Med, Anesthesiol & Reanimat Dept, TR-67600 Zonguldak, Turkiye
来源
MEDICINA-LITHUANIA | 2023年 / 59卷 / 04期
关键词
hemodynamic response; optic nerve sheath; supraglottic airway devices; ultrasound; LARYNGEAL MASK AIRWAY; ELEVATED INTRACRANIAL-PRESSURE; TRACHEAL INTUBATION; LARYNGOSCOPY; ULTRASONOGRAPHY; INSERTION; SURGERY;
D O I
10.3390/medicina59040753
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives: Supraglottic airway devices (SADs) are known to be useful in eliminating the drawbacks of laryngoscopy and tracheal intubation, especially ocular pressure and stress responses. The ultrasonographic measurement of optic nerve sheath diameter (ONSD) reflects increases in intracranial pressure (ICP). In our study, we aimed to compare the effects of SADs on hemodynamic response and ONSD. Materials and Methods: Our prospective study included 90 ASA I-II patients over the age of 18 who did not have a history of difficult intubation or ophthalmic pathology. The patients were randomly divided into three groups based on the laryngeal mask airway (LMA) devices used: ProSeal LMA (pLMA, n = 30), LMA Supreme (sLMA, n = 30), and I-gel (n = 30). The bilateral ONSD measurements and hemodynamic data of the patients who underwent standard anesthesia induction and monitoring were recorded before induction (T0) and 1 min (T1), 5 min (T5), and 10 min (T10) after SAD placement. Results: At all measurement times, the hemodynamic responses and ONSD values of the groups were similar. In all three groups, intergroup hemodynamic changes at T0 and T1 were similar and higher than those at other times of measurement (p < 0.001). The ONSD values of all groups increased at T1, and they tended to return to baseline values afterward (p < 0.001). Conclusions: We concluded that all three SADs could be used safely because they preserved both hemodynamic stability and ONSD changes in their placement processes, and they did not cause elevations in ONSD to an extent that would lead to increased ICP.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] The LMA Supreme: Is it a suitable alternative to the i-gel and LMA ProSeal for airway maintenance in children?
    Jagannathan, Narasimhan
    Hajduk, Jahn
    JOURNAL OF CLINICAL ANESTHESIA, 2017, 40 : 119 - 120
  • [2] Descriptions on Supraglottic Airways: I-gel, LMA Flex, Classic LMA, and ProSeal LMA Do Not Display the Internal Diameter of the Airway Channel
    Madathil, Thushara
    Jose, P. Don
    Panidapu, Nagarjuna
    Jose, Tony
    Devika, P.
    Neema, Praveen K.
    ANNALS OF CARDIAC ANAESTHESIA, 2024, 27 (03) : 286 - 287
  • [3] Is the i-gel supraglottic airway superior to the LMA® ProSeal in paediatric anaesthesia?
    Cumberworth, J.
    Cumberworth, A.
    ANAESTHESIA, 2015, 70 : 15 - 15
  • [4] Use of supraglottic devices with drainage channel in laparoscopic cholecystectomy: a prospective, randomized comparison of LMA Proseal™, LMA Supreme™ and i-gel™
    Belena, J. M.
    Nunez, M.
    Gasco, C.
    Vidal, A.
    Alcojor, A.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2014, 31 : 281 - 281
  • [5] Comparison of the clinical performance of i-gel, LMA Supreme and LMA ProSeal in elective surgery
    Liew, Geoffrey Haw Chieh
    Yu, Esther Dawen
    Shah, Shitalkumar Sharad
    Kothandan, Harikrishnan
    SINGAPORE MEDICAL JOURNAL, 2016, 57 (08) : 432 - 437
  • [6] A COMPARATIVE STUDY OF THREE SUPRAGLOTTIC AIRWAY DEVICES-CLASSIC LMA, PROSEAL LMA AND I-GEL, IN ADULT PATIENTS UNDERGOING ELECTIVE SURGERIES
    Periasamy, Aravind Kumar
    Sivakumar
    Nahar, Afreen
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2018, 7 (09): : 1106 - 1110
  • [7] A new supraglottic airway device: LMA-Supreme™, comparison with LMA-Proseal™
    Hosten, T.
    Gurkan, Y.
    Ozdamar, D.
    Tekin, M.
    Toker, K.
    Solak, M.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2009, 53 (07) : 852 - 857
  • [8] Comparison of i-gel, LMA-supreme, LMA-classic and LMA-proseal as conduits of endotracheal intubation in newborns and infants: A manikin study
    Ankay-Yilbas, Aysun
    Basaran, Betul
    Uzumcugil, Filiz
    Akca, Basak
    Izgi, Murat
    Canbay, Ozgur
    TURKISH JOURNAL OF PEDIATRICS, 2019, 61 (02) : 166 - 173
  • [9] The Supreme Laryngeal Mask Airway™ (LMA): A new neonatal supraglottic device: Comparison with Classic and ProSeal LMA in a manikin
    Trevisanuto, Daniele
    Parotto, Matteo
    Doglioni, Nicoletta
    Ori, Carlo
    Zanardo, Vincenzo
    Micaglio, Massimo
    RESUSCITATION, 2012, 83 (01) : 97 - 100
  • [10] Comparison of size 2 i-gel supraglottic airway with LMA-ProSeal™ and LMA-Classic™ in spontaneously breathing children undergoing elective surgery
    Goyal, Rakhee
    Shukla, Ravindra Nath
    Kumar, Gaurav
    PEDIATRIC ANESTHESIA, 2012, 22 (04) : 355 - 359