Effects of Supraglottic Airway Devices on Hemodynamic Response and Optic Nerve Sheath Diameter: Proseal LMA, LMA Supreme, and I-gel LMA

被引:1
|
作者
Okyay, Rahsan Dilek [1 ]
Kucukosman, Gamze [1 ]
Koksal, Bengu Gulhan [1 ]
Piskin, Ozcan [1 ]
Ayoglu, Hilal [1 ]
机构
[1] Zonguldak Bulent Ecevit Univ, Fac Med, Anesthesiol & Reanimat Dept, TR-67600 Zonguldak, Turkiye
来源
MEDICINA-LITHUANIA | 2023年 / 59卷 / 04期
关键词
hemodynamic response; optic nerve sheath; supraglottic airway devices; ultrasound; LARYNGEAL MASK AIRWAY; ELEVATED INTRACRANIAL-PRESSURE; TRACHEAL INTUBATION; LARYNGOSCOPY; ULTRASONOGRAPHY; INSERTION; SURGERY;
D O I
10.3390/medicina59040753
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives: Supraglottic airway devices (SADs) are known to be useful in eliminating the drawbacks of laryngoscopy and tracheal intubation, especially ocular pressure and stress responses. The ultrasonographic measurement of optic nerve sheath diameter (ONSD) reflects increases in intracranial pressure (ICP). In our study, we aimed to compare the effects of SADs on hemodynamic response and ONSD. Materials and Methods: Our prospective study included 90 ASA I-II patients over the age of 18 who did not have a history of difficult intubation or ophthalmic pathology. The patients were randomly divided into three groups based on the laryngeal mask airway (LMA) devices used: ProSeal LMA (pLMA, n = 30), LMA Supreme (sLMA, n = 30), and I-gel (n = 30). The bilateral ONSD measurements and hemodynamic data of the patients who underwent standard anesthesia induction and monitoring were recorded before induction (T0) and 1 min (T1), 5 min (T5), and 10 min (T10) after SAD placement. Results: At all measurement times, the hemodynamic responses and ONSD values of the groups were similar. In all three groups, intergroup hemodynamic changes at T0 and T1 were similar and higher than those at other times of measurement (p < 0.001). The ONSD values of all groups increased at T1, and they tended to return to baseline values afterward (p < 0.001). Conclusions: We concluded that all three SADs could be used safely because they preserved both hemodynamic stability and ONSD changes in their placement processes, and they did not cause elevations in ONSD to an extent that would lead to increased ICP.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] A comparison of i-gel(TM) and LMA Supreme(TM) in anesthetized and paralyzed children
    Kim, Hyuk
    Lee, Ji Yeon
    Lee, Seung Yoon
    Park, Sang Yoong
    Lee, Seung Cheol
    Chung, Chan Jong
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2014, 67 (05) : 317 - 322
  • [32] Comparison of i-gel (R) and LMA Supreme (R) during laparoscopic cholecystectomy
    Park, Sang Yoong
    Rim, Jong Cheol
    Kim, Hyuk
    Lee, Ji Hyeon
    Chung, Chan Jong
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2015, 68 (05) : 455 - 461
  • [33] Randomized prospective trial comparing two supraglottic airway devices: i-gel™ and LMA-Supreme™ in paralyzed patients [Étude prospective randomisée comparant deux dispositifs pour voie aérienne supraglottique: i-gel™ et LMA-Supreme™ chez des patients paralysés]
    Joly N.
    Poulin L.-P.
    Tanoubi I.
    Drolet P.
    Donati F.
    St-Pierre P.
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2014, 61 (9): : 794 - 800
  • [34] A study of effect of lateral position on oropharyngeal seal pressure of i-gel® and ProSeal™ LMA in children
    Thakur, Deepali P.
    Malde, Anila D.
    INDIAN JOURNAL OF ANAESTHESIA, 2020, 64 (02) : 125 - 130
  • [35] Comparison of Clinical Performance of I-Gel((TM)) with LMA-Proseal((TM)) in Elective Surgeries
    Singh, Ishwar
    Gupta, Monika
    Tandon, Mansi
    INDIAN JOURNAL OF ANAESTHESIA, 2009, 53 (03) : 302 - 305
  • [36] Using Proseal LMA and I-gel for difficult airway management in patient with diffuse tracheal stenosis and pulmonary artery sling
    Kosucu, M.
    Eroglu, A.
    Besir, A.
    Cansu, A.
    BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2013, 114 (07): : 418 - 420
  • [37] Randomised comparison of the LMA Supreme™ with the I-Gel™ in spontaneously breathing anaesthetised adult patients
    Chew, E. F. F.
    Hashim, N. H. M.
    Wang, C. Y.
    ANAESTHESIA AND INTENSIVE CARE, 2010, 38 (06) : 1018 - 1022
  • [38] Magnetic resonance imaging study of the in vivo position of the extraglottic airway devices i-gel and LMA-Supreme in anaesthetized human volunteers
    Russo, S. G.
    Cremer, S.
    Eich, C.
    Jipp, M.
    Cohnen, J.
    Strack, M.
    Quintel, M.
    Mohr, A.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 109 (06) : 996 - 1004
  • [39] Comparing leak pressure of LMA® ProSeal™ versus i-gel® at head rotation: a randomized controlled trial
    Chaki, Tomohiro
    Koizumi, Masatsugu
    Tachibana, Shunsuke
    Matsumoto, Tomomi
    Kumagai, Tomoe
    Hashimoto, Yuki
    Yamakage, Michiaki
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2024, 71 (01): : 66 - 76
  • [40] Comparison of LMA Supreme™ with i-geI™ and LMA ProSeal™ in children for airway management during general anaesthesia: A meta-analysis of randomized controlled trials
    Bhattacharjee, Sulagna
    Som, Anirban
    Maitra, Souvik
    JOURNAL OF CLINICAL ANESTHESIA, 2017, 41 : 5 - 10