Effects of Supraglottic Airway Devices on Hemodynamic Response and Optic Nerve Sheath Diameter: Proseal LMA, LMA Supreme, and I-gel LMA

被引:1
|
作者
Okyay, Rahsan Dilek [1 ]
Kucukosman, Gamze [1 ]
Koksal, Bengu Gulhan [1 ]
Piskin, Ozcan [1 ]
Ayoglu, Hilal [1 ]
机构
[1] Zonguldak Bulent Ecevit Univ, Fac Med, Anesthesiol & Reanimat Dept, TR-67600 Zonguldak, Turkiye
来源
MEDICINA-LITHUANIA | 2023年 / 59卷 / 04期
关键词
hemodynamic response; optic nerve sheath; supraglottic airway devices; ultrasound; LARYNGEAL MASK AIRWAY; ELEVATED INTRACRANIAL-PRESSURE; TRACHEAL INTUBATION; LARYNGOSCOPY; ULTRASONOGRAPHY; INSERTION; SURGERY;
D O I
10.3390/medicina59040753
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives: Supraglottic airway devices (SADs) are known to be useful in eliminating the drawbacks of laryngoscopy and tracheal intubation, especially ocular pressure and stress responses. The ultrasonographic measurement of optic nerve sheath diameter (ONSD) reflects increases in intracranial pressure (ICP). In our study, we aimed to compare the effects of SADs on hemodynamic response and ONSD. Materials and Methods: Our prospective study included 90 ASA I-II patients over the age of 18 who did not have a history of difficult intubation or ophthalmic pathology. The patients were randomly divided into three groups based on the laryngeal mask airway (LMA) devices used: ProSeal LMA (pLMA, n = 30), LMA Supreme (sLMA, n = 30), and I-gel (n = 30). The bilateral ONSD measurements and hemodynamic data of the patients who underwent standard anesthesia induction and monitoring were recorded before induction (T0) and 1 min (T1), 5 min (T5), and 10 min (T10) after SAD placement. Results: At all measurement times, the hemodynamic responses and ONSD values of the groups were similar. In all three groups, intergroup hemodynamic changes at T0 and T1 were similar and higher than those at other times of measurement (p < 0.001). The ONSD values of all groups increased at T1, and they tended to return to baseline values afterward (p < 0.001). Conclusions: We concluded that all three SADs could be used safely because they preserved both hemodynamic stability and ONSD changes in their placement processes, and they did not cause elevations in ONSD to an extent that would lead to increased ICP.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] i-gel (TM) in Ambulatory Surgery: A Comparison with LMA-ProSeal (TM) in Paralyzed Anaesthetized Patients
    Das, Anjan
    Majumdar, Saikat
    Mukherjef, Anindya
    Mitra, Tapobrata
    Kundu, Ratul
    Hajra, Bimal Kumar
    Mukherjef, Dipankar
    Das, Bibhukalyani
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2014, 8 (03) : 80 - 84
  • [42] Comparison of Proseal LMA with i-Gel in children under controlled ventilation: a prospective randomised clinical study
    Shiveshi, Praveen
    Anandaswamy, Tejesh Channasandra
    BRAZILIAN JOURNAL OF ANESTHESIOLOGY, 2022, 72 (02): : 247 - 252
  • [43] Application of the LMA-Supreme™ and i-gel™ laryngeal masks during pelvic operations in adults
    Wang, Fei
    Zhang, Rui
    ASIAN JOURNAL OF SURGERY, 2016, 39 (01) : 1 - 5
  • [44] Comparison of the I-gel Laryngeal Mask Airway With the LMA-Supreme for Airway Management in Patients Undergoing Elective Lumbar Vertebral Surgery
    Kang, Fang
    Li, Juan
    Chai, XiaoQing
    Yu, JinGui
    Zhang, HuaMing
    Tang, ChaoLiang
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2015, 27 (01) : 37 - 41
  • [45] Contrast of oropharyngeal leak pressure and clinical performance of I-gel™ and LMA ProSeal™ in patients: A meta-analysis
    Tan, Yuan
    Jiang, Jingyao
    Wang, Rurong
    PLOS ONE, 2022, 17 (12):
  • [46] Comparison of Size 2.5 i-gel (TM) with ProSeal LMA (TM) in Anaesthetised, Paralyzed Children Undergoing Elective Surgery
    Mitra, Subhro
    Das, Bikramjit
    Jamil, Shahin N.
    NORTH AMERICAN JOURNAL OF MEDICAL SCIENCES, 2012, 4 (10) : 453 - 457
  • [47] Comparison of Outcome of Laryngeal Mask Airway (LMA Classic) and I-Gel Devices in Patients Undergoing General Anaesthesia in Elective Surgeries
    Dar, Shahid Rasool
    Hussain, Riaz
    Nazeer, Tahir
    Tahir, Amna
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2015, 9 (03): : 1036 - 1038
  • [48] Comparison of the LMA Supreme vs the i-gel™ in paralysed patients undergoing gynaecological laparoscopic surgery with controlled ventilation
    Teoh, W. H. L.
    Lee, K. M.
    Suhitharan, T.
    Yahaya, Z.
    Teo, M. M.
    Sia, A. T. H.
    ANAESTHESIA, 2010, 65 (12) : 1173 - 1179
  • [49] Comparison of oropharyngeal leak pressure and clinical performance of LMA ProSeal and i-gel® in adults: Meta-analysis and systematic review
    Shin, Hye Won
    Yoo, Hae Na
    Bae, Go Eun
    Chang, Jun Chul
    Park, Min Kyung
    You, Hae Seun
    Kim, Hyun Jung
    Ahn, Hyung Sik
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2016, 44 (03) : 405 - 418
  • [50] Ultrasonographic assessment of altered anatomical relationship between internal jugular vein and common carotid artery with supraglottic airway in children: LMA vs i-gel™
    Khemka, Rakhi
    Rastogi, Sonal
    Chakraborty, Arunangshu
    Sinha, Subir
    INDIAN JOURNAL OF ANAESTHESIA, 2019, 63 (02) : 114 - 118