VERIFICATION OF A 2-DIMENSIONAL PENCIL BEAM ARC ELECTRON DOSE CALCULATION ALGORITHM

被引:7
|
作者
ANTOLAK, JA
ELKHATIB, E
SCRIMGER, JW
机构
关键词
ELECTRONS; DOSIMETRY; ARC THERAPY; PENCIL BEAMS; LUNG PHANTOM;
D O I
10.1118/1.596960
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The dosimetry of arced electron beams is of increasing importance because of the increased capabilities of modern linear accelerators. A practical pencil beam algorithm has been developed for arc electron beams and is capable of using computed tomography information for heterogeneity corrections. For homogeneous phantoms, the maximum dose and bremsstrahlung components are predicted very accurately, that is, within 1% of the maximum dose. However, the depth of maximum dose (treatment depth) is predicted to be deeper than measurement, as much as 0.7 cm deeper. For a heterogeneous lung phantom, the discrepancies are as high as 30%, but the accuracy of dose calculation is consistent with conventional stationary pencil beam algorithms. It was concluded that improvements in the dose prediction are possible with more accurate calculations of the pencil beam widths and the incorporation of range straggling into the algorithm.
引用
收藏
页码:1735 / 1742
页数:8
相关论文
共 50 条
  • [41] Pacemakers in radiotherapy - how accurate is the calculation of dose on cardiac pacemakers with a Pencil Beam algorithm?
    Scheermann, J.
    Walke, M.
    Gademann, G.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 : 165 - 165
  • [42] Evaluation of a Pencil Beam Algorithm and Pencil Beam Redefinition Algorithm for Bolus Electron Conformal Therapy
    Kavanaugh, J.
    Carver, R.
    Chu, C.
    Mancuso, G.
    Hogstrom, K.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [43] A pencil beam algorithm for proton dose calculations
    Hong, L
    Goitein, M
    Bucciolini, M
    Comiskey, R
    Gottschalk, B
    Rosenthal, S
    Serago, C
    Urie, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (08): : 1305 - 1330
  • [44] EVALUATION OF ELECTRON PENCIL BEAM DOSE CALCULATIONS
    HOGSTROM, KR
    MEDICAL PHYSICS, 1985, 12 (04) : 554 - 554
  • [45] A pencil beam dose calculation model for CyberKnife system
    Liang, Bin
    Li, Yongbao
    Liu, Bo
    Zhou, Fugen
    Xu, Shouping
    Wu, Qiuwen
    MEDICAL PHYSICS, 2016, 43 (10) : 5380 - 5391
  • [46] Verification of a proton treatment-planning pencil-beam dose algorithm with Monte Carlo
    Titt, U.
    Zheng, Y.
    Zhu, X.
    Mohan, R.
    Newhauser, W.
    MEDICAL PHYSICS, 2006, 33 (06) : 2149 - 2149
  • [47] A generalized 2D pencil beam scaling algorithm for proton dose calculation in heterogeneous slab geometries
    Westerly, David C.
    Mo, Xiaohu
    Tome, Wolfgang A.
    Mackie, Thomas R.
    DeLuca, Paul M., Jr.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [48] Evaluation of an electron Monte Carlo dose calculation algorithm for electron beam radiotherapy
    Hu, A.
    Song, H.
    Chen, Z.
    Zhou, S.
    Yin, F.
    MEDICAL PHYSICS, 2006, 33 (06) : 2099 - 2099
  • [49] Dose Comparison between Proton Pencil Beam and Monte Carlo Dose Calculation Algorithm in Lung Cancer Patients
    Maes, D.
    Bowen, S. R.
    Fung, A.
    Saini, J.
    Bloch, C.
    Egan, A.
    Zeng, J.
    Rengan, R.
    Wong, T. P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E694 - E694
  • [50] Modelling pencil-beam divergence with the electron pencil-beam redefinition algorithm
    Boyd, RA
    Hogstrom, KR
    White, RA
    Starkschall, G
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (11): : 2841 - 2856