VERIFICATION OF A 2-DIMENSIONAL PENCIL BEAM ARC ELECTRON DOSE CALCULATION ALGORITHM

被引:7
|
作者
ANTOLAK, JA
ELKHATIB, E
SCRIMGER, JW
机构
关键词
ELECTRONS; DOSIMETRY; ARC THERAPY; PENCIL BEAMS; LUNG PHANTOM;
D O I
10.1118/1.596960
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The dosimetry of arced electron beams is of increasing importance because of the increased capabilities of modern linear accelerators. A practical pencil beam algorithm has been developed for arc electron beams and is capable of using computed tomography information for heterogeneity corrections. For homogeneous phantoms, the maximum dose and bremsstrahlung components are predicted very accurately, that is, within 1% of the maximum dose. However, the depth of maximum dose (treatment depth) is predicted to be deeper than measurement, as much as 0.7 cm deeper. For a heterogeneous lung phantom, the discrepancies are as high as 30%, but the accuracy of dose calculation is consistent with conventional stationary pencil beam algorithms. It was concluded that improvements in the dose prediction are possible with more accurate calculations of the pencil beam widths and the incorporation of range straggling into the algorithm.
引用
收藏
页码:1735 / 1742
页数:8
相关论文
共 50 条
  • [21] Clinical Implementation of a GPU Accelerated Pencil Beam Dose Calculation Algorithm
    Chen, H.
    Xiao, Z.
    Du, D.
    Yang, D.
    Mutic, S.
    Li, H.
    MEDICAL PHYSICS, 2012, 39 (06) : 3823 - 3823
  • [22] Polar Coordinate Based Pencil Beam Dose Calculation Algorithm for VMAT
    Tseng, W.
    Lu, B.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [23] A 3-DIMENSIONAL NONCOPLANAR ELECTRON PENCIL BEAM ALGORITHM
    KOOY, HM
    CHIN, L
    KIJEWSKI, PK
    MEDICAL PHYSICS, 1987, 14 (04) : 706 - 706
  • [24] A 3-DIMENSIONAL ELECTRON PENCIL-BEAM ALGORITHM
    KOOY, HM
    RASHID, H
    PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (02): : 229 - 243
  • [25] Electron beam dose calculation: Hybrid pencil beam model extended for small fields
    Gou, CJ
    Zeng, G
    Luo, ZM
    ACTA PHYSICA SLOVACA, 2003, 53 (03) : 259 - 265
  • [26] Verification Of A Novel Pencil-beam Based Dose Calculation Algorithm With Heterogeneity Correction For Situations Of Lateral Electron Disequilibrium And Comparison With Monte Carlo Calculations
    Wertz, H.
    Jahnke, L.
    Schneider, F.
    Polednik, M.
    Fleckenstein, J.
    Lohr, F.
    Wenz, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S903 - S903
  • [27] Experimental verification and clinical implementation of a commercial Monte Carlo electron beam dose calculation algorithm
    Fragosoa, Margarida
    Pillai, Sushakumari
    Solberg, Timothy D.
    Chetty, Indrin J.
    MEDICAL PHYSICS, 2008, 35 (03) : 1028 - 1038
  • [28] Use of pencil-beam redefinition algorithm for electron are dose calculations
    Chi, P
    Boyd, R
    Hogstrom, K
    MEDICAL PHYSICS, 2003, 30 (06) : 1518 - 1518
  • [29] Test procedures for verification of an electron pencil beam algorithm implemented for treatment planning
    Blomquist, M
    Karlsson, M
    Karlsson, M
    RADIOTHERAPY AND ONCOLOGY, 1996, 39 (03) : 271 - 286
  • [30] Dose Calculation Algorithm for External Neutron Radiotherapy Based On Pencil Beam Method
    Moiseev, A.
    Klimanov, V.
    MEDICAL PHYSICS, 2012, 39 (06) : 3830 - 3830