VERIFICATION OF A 2-DIMENSIONAL PENCIL BEAM ARC ELECTRON DOSE CALCULATION ALGORITHM

被引:7
|
作者
ANTOLAK, JA
ELKHATIB, E
SCRIMGER, JW
机构
关键词
ELECTRONS; DOSIMETRY; ARC THERAPY; PENCIL BEAMS; LUNG PHANTOM;
D O I
10.1118/1.596960
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The dosimetry of arced electron beams is of increasing importance because of the increased capabilities of modern linear accelerators. A practical pencil beam algorithm has been developed for arc electron beams and is capable of using computed tomography information for heterogeneity corrections. For homogeneous phantoms, the maximum dose and bremsstrahlung components are predicted very accurately, that is, within 1% of the maximum dose. However, the depth of maximum dose (treatment depth) is predicted to be deeper than measurement, as much as 0.7 cm deeper. For a heterogeneous lung phantom, the discrepancies are as high as 30%, but the accuracy of dose calculation is consistent with conventional stationary pencil beam algorithms. It was concluded that improvements in the dose prediction are possible with more accurate calculations of the pencil beam widths and the incorporation of range straggling into the algorithm.
引用
收藏
页码:1735 / 1742
页数:8
相关论文
共 50 条
  • [31] A Fast Finite Size Pencil Beam Algorithm for Dose Calculation Using GPUs
    Arhjoul, L.
    Jinag, L.
    Solberg, T.
    Despres, P.
    Mao, W.
    MEDICAL PHYSICS, 2012, 39 (06) : 4020 - 4021
  • [32] ACCELERATION OF A PENCIL-BEAM DOSE CALCULATION ALGORITHM WITH GRAPHICS PROCESSING UNITS
    Arhjoul, L.
    Hissoiny, S.
    Ozell, B.
    Despres, P.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S70 - S70
  • [33] A PENCIL BEAM MODEL FOR PHOTON DOSE CALCULATION
    AHNESJO, A
    SAXNER, M
    TREPP, A
    MEDICAL PHYSICS, 1992, 19 (02) : 263 - 273
  • [34] THE OPTIMIZATION OF PENCIL BEAM WIDTHS FOR USE IN AN ELECTRON PENCIL BEAM ALGORITHM
    MCPARLAND, BJ
    CUNNINGHAM, JR
    WOO, MK
    MEDICAL PHYSICS, 1988, 15 (04) : 489 - 497
  • [35] Evaluation of a commercial three-dimensional electron pencil beam algorithm
    S. Margaret Mercy Healthcare Centers, Hammond, IN 46320, United States
    不详
    MED. PHYS., 1 (91-101):
  • [36] Evaluation of a commercial three-dimensional electron pencil beam algorithm
    MullerRunkel, R
    Cho, SH
    MEDICAL PHYSICS, 1997, 24 (01) : 91 - 101
  • [37] Evaluation of a Modified Pencil Beam Algorithm Dose Calculation in the Presence of Intensity Modulators for Intensity Modulated Bolus Electron Beam Conformal Therapy
    Hilliard, E.
    Carver, R.
    Hogstrom, K.
    Erhart, K.
    MEDICAL PHYSICS, 2019, 46 (06) : E230 - E231
  • [38] A comparison of electron beam dose calculation accuracy between treatment planning systems using either a pencil beam or a Monte Carlo algorithm
    Ding, GX
    Cygler, JE
    Yu, CW
    Kalach, NI
    Daskalov, G
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : 622 - 633
  • [39] Calculating percent depth dose with the electron pencil-beam redefinition algorithm
    Price, Michael J.
    Hogstrom, Kenneth R.
    Antolak, John A.
    White, R. Allen
    Bloch, Charles D.
    Boyd, Robert A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (02): : 61 - 75
  • [40] Electron pencil-beam redefinition algorithm dose calculations in the presence of heterogeneities
    Boyd, RA
    Hogstrom, KR
    Starkschall, G
    MEDICAL PHYSICS, 2001, 28 (10) : 2096 - 2104