A generalized 2D pencil beam scaling algorithm for proton dose calculation in heterogeneous slab geometries

被引:9
|
作者
Westerly, David C. [1 ]
Mo, Xiaohu [2 ]
Tome, Wolfgang A. [2 ,3 ,4 ]
Mackie, Thomas R. [2 ,5 ]
DeLuca, Paul M., Jr. [2 ]
机构
[1] Univ Colorado, Sch Med, Dept Radiat Oncol, Aurora, CO 80045 USA
[2] Univ Wisconsin, Dept Med Phys, Sch Med & Publ Hlth, Madison, WI 53705 USA
[3] Albert Einstein Coll Med, Inst Oncophys, Bronx, NY 10461 USA
[4] Montefiore Med Ctr, Dept Radiat Oncol, Div Med Phys, Bronx, NY 10461 USA
[5] Univ Wisconsin, Sch Med & Publ Hlth, Dept Human Oncol, Madison, WI 53792 USA
关键词
2D scaling; proton dose calculation; heterogeneity corrections; nonlocal scattering power models; local scattering power models; MULTIPLE COULOMB SCATTERING; MONTE-CARLO SIMULATIONS; CHARGED-PARTICLES; THERAPY; ENERGY; VERIFICATION; RADIOTHERAPY; CONVOLUTION; MEDIA; MODEL;
D O I
10.1118/1.4804055
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Pencil beam algorithms are commonly used for proton therapy dose calculations. Szymanowski and Oelfke ["Two-dimensional pencil beam scaling: An improved proton dose algorithm for heterogeneous media," Phys. Med. Biol. 47, 3313-3330 (2002)] developed a two-dimensional (2D) scaling algorithm which accurately models the radial pencil beam width as a function of depth in heterogeneous slab geometries using a scaled expression for the radial kernel width in water as a function of depth and kinetic energy. However, an assumption made in the derivation of the technique limits its range of validity to cases where the input expression for the radial kernel width in water is derived from a local scattering power model. The goal of this work is to derive a generalized form of 2D pencil beam scaling that is independent of the scattering power model and appropriate for use with any expression for the radial kernel width in water as a function of depth. Methods: Using Fermi-Eyges transport theory, the authors derive an expression for the radial pencil beam width in heterogeneous slab geometries which is independent of the proton scattering power and related quantities. The authors then perform test calculations in homogeneous and heterogeneous slab phantoms using both the original 2D scaling model and the new model with expressions for the radial kernel width in water computed from both local and nonlocal scattering power models, as well as a nonlocal parameterization of Moliere scattering theory. In addition to kernel width calculations, dose calculations are also performed for a narrow Gaussian proton beam. Results: Pencil beam width calculations indicate that both 2D scaling formalisms perform well when the radial kernel width in water is derived from a local scattering power model. Computing the radial kernel width from a nonlocal scattering model results in the local 2D scaling formula under-predicting the pencil beam width by as much as 1.4 mm (21%) at the depth of the Bragg peak for a 220 MeV proton beam in homogeneous water. This translates into a 32% dose discrepancy for a 5 mm Gaussian proton beam. Similar trends were observed for calculations made in heterogeneous slab phantoms where it was also noted that errors tend to increase with greater beam penetration. The generalized 2D scaling model performs well in all situations, with a maximum dose error of 0.3% at the Bragg peak in a heterogeneous phantom containing 3 cm of hard bone. Conclusions: The authors have derived a generalized form of 2D pencil beam scaling which is independent of the proton scattering power model and robust to the functional form of the radial kernel width in water used for the calculations. Sample calculations made with this model show excellent agreement with expected values in both homogeneous water and heterogeneous phantoms. (c) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Two-dimensional pencil beam scaling: an improved proton dose algorithm for heterogeneous media
    Szymanowski, H
    Oelfke, U
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (18): : 3313 - 3330
  • [2] A pencil beam algorithm for proton dose calculations
    Hong, L
    Goitein, M
    Bucciolini, M
    Comiskey, R
    Gottschalk, B
    Rosenthal, S
    Serago, C
    Urie, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (08): : 1305 - 1330
  • [3] Delta-Functional Multi Segmented Pencil Beam Algorithm for Highly Accurate Proton Dose Calculation in Heterogeneous Body
    Egashira, Y.
    Nishio, T.
    Kameoka, S.
    Matsuura, T.
    Uesaka, M.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [4] A 3D pencil-beam-based superposition algorithm for photon dose calculation in heterogeneous media
    Tillikainen, L.
    Helminen, H.
    Torsti, T.
    Siljamaki, S.
    Alakuijala, J.
    Pyyry, J.
    Ulmer, W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (14): : 3821 - 3839
  • [5] Calculation of physical parameters in pencil beam dose calculation algorithm
    School of Information Science and Engineering, Northeastern University, Shenyang 110004, China
    不详
    不详
    Dongbei Daxue Xuebao, 2008, 3 (437-440): : 437 - 440
  • [6] A PENCIL BEAM ALGORITHM FOR HELIUM ION BEAM DOSE CALCULATION
    Fuchs, H.
    Stroebele, J.
    Schreiner, T.
    Georg, D.
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S39 - S40
  • [7] Evaluating the Dose Accuracy of a 2D Ion Chamber Array in High Dose Rate Pencil Beam Scanning Proton Beam
    Perles, L.
    Mascia, A.
    Piskulich, F.
    Lepage, R.
    Zhang, Y.
    Giebeler, A.
    Dong, L.
    MEDICAL PHYSICS, 2014, 41 (06)
  • [8] Dose Comparison between Proton Pencil Beam and Monte Carlo Dose Calculation Algorithm in Lung Cancer Patients
    Maes, D.
    Bowen, S. R.
    Fung, A.
    Saini, J.
    Bloch, C.
    Egan, A.
    Zeng, J.
    Rengan, R.
    Wong, T. P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E694 - E694
  • [9] DOSIMETRIC VERIFICATION OF A 3-D ELECTRON PENCIL BEAM DOSE CALCULATION ALGORITHM
    MCSHAN, DL
    FRAASS, BA
    TENHAKEN, RK
    MEDICAL PHYSICS, 1994, 21 (01) : 13 - 23
  • [10] Implementation of apertures in a proton pencil-beam dose algorithm
    Depauw, N.
    Kooy, H. M.
    Daartz, J.
    Bussiere, M.
    Batin, E.
    Madden, T.
    Williams, M.
    Schueman, J.
    Clasie, B. M.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (02)