A generalized 2D pencil beam scaling algorithm for proton dose calculation in heterogeneous slab geometries

被引:9
|
作者
Westerly, David C. [1 ]
Mo, Xiaohu [2 ]
Tome, Wolfgang A. [2 ,3 ,4 ]
Mackie, Thomas R. [2 ,5 ]
DeLuca, Paul M., Jr. [2 ]
机构
[1] Univ Colorado, Sch Med, Dept Radiat Oncol, Aurora, CO 80045 USA
[2] Univ Wisconsin, Dept Med Phys, Sch Med & Publ Hlth, Madison, WI 53705 USA
[3] Albert Einstein Coll Med, Inst Oncophys, Bronx, NY 10461 USA
[4] Montefiore Med Ctr, Dept Radiat Oncol, Div Med Phys, Bronx, NY 10461 USA
[5] Univ Wisconsin, Sch Med & Publ Hlth, Dept Human Oncol, Madison, WI 53792 USA
关键词
2D scaling; proton dose calculation; heterogeneity corrections; nonlocal scattering power models; local scattering power models; MULTIPLE COULOMB SCATTERING; MONTE-CARLO SIMULATIONS; CHARGED-PARTICLES; THERAPY; ENERGY; VERIFICATION; RADIOTHERAPY; CONVOLUTION; MEDIA; MODEL;
D O I
10.1118/1.4804055
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Pencil beam algorithms are commonly used for proton therapy dose calculations. Szymanowski and Oelfke ["Two-dimensional pencil beam scaling: An improved proton dose algorithm for heterogeneous media," Phys. Med. Biol. 47, 3313-3330 (2002)] developed a two-dimensional (2D) scaling algorithm which accurately models the radial pencil beam width as a function of depth in heterogeneous slab geometries using a scaled expression for the radial kernel width in water as a function of depth and kinetic energy. However, an assumption made in the derivation of the technique limits its range of validity to cases where the input expression for the radial kernel width in water is derived from a local scattering power model. The goal of this work is to derive a generalized form of 2D pencil beam scaling that is independent of the scattering power model and appropriate for use with any expression for the radial kernel width in water as a function of depth. Methods: Using Fermi-Eyges transport theory, the authors derive an expression for the radial pencil beam width in heterogeneous slab geometries which is independent of the proton scattering power and related quantities. The authors then perform test calculations in homogeneous and heterogeneous slab phantoms using both the original 2D scaling model and the new model with expressions for the radial kernel width in water computed from both local and nonlocal scattering power models, as well as a nonlocal parameterization of Moliere scattering theory. In addition to kernel width calculations, dose calculations are also performed for a narrow Gaussian proton beam. Results: Pencil beam width calculations indicate that both 2D scaling formalisms perform well when the radial kernel width in water is derived from a local scattering power model. Computing the radial kernel width from a nonlocal scattering model results in the local 2D scaling formula under-predicting the pencil beam width by as much as 1.4 mm (21%) at the depth of the Bragg peak for a 220 MeV proton beam in homogeneous water. This translates into a 32% dose discrepancy for a 5 mm Gaussian proton beam. Similar trends were observed for calculations made in heterogeneous slab phantoms where it was also noted that errors tend to increase with greater beam penetration. The generalized 2D scaling model performs well in all situations, with a maximum dose error of 0.3% at the Bragg peak in a heterogeneous phantom containing 3 cm of hard bone. Conclusions: The authors have derived a generalized form of 2D pencil beam scaling which is independent of the proton scattering power model and robust to the functional form of the radial kernel width in water used for the calculations. Sample calculations made with this model show excellent agreement with expected values in both homogeneous water and heterogeneous phantoms. (c) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Dose Calculation Algorithm for External Neutron Radiotherapy Based On Pencil Beam Method
    Moiseev, A.
    Klimanov, V.
    MEDICAL PHYSICS, 2012, 39 (06) : 3830 - 3830
  • [32] A Fast Finite Size Pencil Beam Algorithm for Dose Calculation Using GPUs
    Arhjoul, L.
    Jinag, L.
    Solberg, T.
    Despres, P.
    Mao, W.
    MEDICAL PHYSICS, 2012, 39 (06) : 4020 - 4021
  • [33] ACCELERATION OF A PENCIL-BEAM DOSE CALCULATION ALGORITHM WITH GRAPHICS PROCESSING UNITS
    Arhjoul, L.
    Hissoiny, S.
    Ozell, B.
    Despres, P.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S70 - S70
  • [34] Sub-second pencil beam dose calculation on GPU for adaptive proton therapy
    da Silva, Joakim
    Ansorge, Richard
    Jena, Rajesh
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (12): : 4777 - 4795
  • [35] Fast Pencil Beam Dose calculation for Proton Therapy Using a Double-Gaussian Beam Model
    da Silva, Joakim
    Ansorge, Richard
    Jena, Rajesh
    FRONTIERS IN ONCOLOGY, 2015, 5
  • [36] Optimizing an analytical dose calculation algorithm for fast 2D calculations
    Lorenz, Friedlieb
    Richter, Henning
    Zygmanski, Piotr
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2010, 20 (01): : 61 - 67
  • [37] Improvements in pencil beam scanning proton therapy dose calculation accuracy in brain tumor cases with a commercial Monte Carlo algorithm
    Widesott, Lamberto
    Lorentini, Stefano
    Fracchiolla, Francesco
    Farace, Paolo
    Schwarz, Marco
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (14):
  • [38] A GPU-Based Pencil Beam Algorithm for Dose Calculations in Proton Radiation Therapy
    Kalantzis, G.
    Leventouri, T.
    Tachibana, H.
    Shang, C.
    MEDICAL PHYSICS, 2015, 42 (06) : 3339 - 3339
  • [39] Performance of a Hybrid Monte Carlo-Pencil Beam Dose Algorithm for Proton Therapy
    Montero, A. Barragan
    Souris, K.
    Sanchez-Parcerisa, D.
    Lee, J.
    Sterpin, E.
    MEDICAL PHYSICS, 2017, 44 (06) : 2994 - 2994
  • [40] A GPU-based pencil beam algorithm for dose calculations in proton radiation therapy
    Kalantzis G.
    Leventouri T.
    Tachibana H.
    Shang C.
    International Journal of Networked and Distributed Computing, 2015, 3 (4) : 243 - 249