Performance evaluation of multi-passive solar applications of a non air-conditioned building

被引:13
|
作者
Kumar, Rakesh [1 ]
Garg, S. N. [1 ]
Kaushik, S. C. [1 ]
机构
[1] Indian Inst Technol, Ctr Energy Studies, New Delhi 110016, India
关键词
solar shading; insulation; ACH; composite; hot and dry; warm and humid;
D O I
10.1504/IJETM.2005.006507
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper describes the performance evaluation of solar passive cooling techniques such as solar shading insulation of building components and air exchange rate. Thermal performance of the non air-conditioned building is predicted by analysing a one-dimensional numerical model. Numerical calculation has been made corresponding to three different climates, viz. composite, hot and dry and warm and humid. A decrease in the indoor temperature by about 2.5 degrees C to 4.5 degrees C is noticed for solar shading. Results modified with insulation and controlled air exchange rate show a further decrease of 4.4 degrees C to 6.8 degrees C in room temperature. For a shaded and selectively ventilated building, 2 cm of thermal insulation gives the same result as 8-10 cm of insulation for a conventional building, which is non-shaded and not ventilated. The analysis suggests that solar shading along with other two options is quite useful to development of passive cooling system to maintain indoor room air temperature lower than the conventional building.
引用
收藏
页码:60 / 75
页数:16
相关论文
共 50 条
  • [41] Adaptive comfort temperature model of air-conditioned building in Hong Kong
    Mui, KWH
    Chan, WTD
    BUILDING AND ENVIRONMENT, 2003, 38 (06) : 837 - 852
  • [42] Performance evaluation of a passive solar building in Western Himalayas
    Chandel, S. S.
    Aggarwal, R. K.
    RENEWABLE ENERGY, 2008, 33 (10) : 2166 - 2173
  • [43] MEASUREMENT OF AIRBORNE RADON CONCENTRATION IN AIR-CONDITIONED BUILDING BY USING SSNTD
    LU, YQ
    FENG, YH
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 22 (1-4): : 383 - 385
  • [44] SOLAR THERMAL-ANALYSIS OF HONEYCOMB ROOF COVER SYSTEM FOR ENERGY-CONSERVATION IN AN AIR-CONDITIONED BUILDING
    KAUSHIKA, ND
    SHARMA, PK
    PRIYA, RP
    ENERGY AND BUILDINGS, 1992, 18 (01) : 45 - 49
  • [45] EFFECT OF SPRING GRASS FIRES ON INDOOR AIR QUALITY IN AIR-CONDITIONED OFFICE BUILDING
    Pauraite, J.
    Garbariene, I.
    Minderyte, A.
    Dudoitis, V.
    Mainelis, G.
    Davuliene, L.
    Uoginte, I.
    Plauskaite, K.
    Bycenkiene, S.
    LITHUANIAN JOURNAL OF PHYSICS, 2021, 61 (03): : 191 - 204
  • [46] Thermal comfort evaluation of an air-conditioned lecture theatre in the tropics
    Cheong, KWD
    Djunaedy, E
    Chua, YL
    Tham, KW
    Sekhar, SC
    Wong, NH
    Ullah, MB
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 1633 - 1640
  • [47] Energy Performance Indicators for Air-Conditioned Museums in Tropical Climates
    Lucchi, Elena
    BUILDINGS, 2024, 14 (08)
  • [48] Dynamic evaluation of thermal comfort environment of air-conditioned buildings
    Wang Hanqing
    Huang Chunhua
    Liu Zhiqiang
    Tang Guangfa
    Liu Yingyun
    Wang Zhiyong
    BUILDING AND ENVIRONMENT, 2006, 41 (11) : 1522 - 1529
  • [49] Appraisal of Thermal Comfort in Non-Air-conditioned and Air-conditioned Railway Pantry Car Kitchens
    Alam, Md. Sarfaraz
    Muthiah, Arunachalam
    Salve, Urmi Ravindra
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2020, 12 (08): : 318 - 327
  • [50] Evaluation on screening strategies for indoor air quality assessments in air-conditioned offices
    Wong, L. T.
    Mui, K. W.
    Hui, P. S.
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2009, 30 (03): : 203 - 212