Performance evaluation of multi-passive solar applications of a non air-conditioned building

被引:13
|
作者
Kumar, Rakesh [1 ]
Garg, S. N. [1 ]
Kaushik, S. C. [1 ]
机构
[1] Indian Inst Technol, Ctr Energy Studies, New Delhi 110016, India
关键词
solar shading; insulation; ACH; composite; hot and dry; warm and humid;
D O I
10.1504/IJETM.2005.006507
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper describes the performance evaluation of solar passive cooling techniques such as solar shading insulation of building components and air exchange rate. Thermal performance of the non air-conditioned building is predicted by analysing a one-dimensional numerical model. Numerical calculation has been made corresponding to three different climates, viz. composite, hot and dry and warm and humid. A decrease in the indoor temperature by about 2.5 degrees C to 4.5 degrees C is noticed for solar shading. Results modified with insulation and controlled air exchange rate show a further decrease of 4.4 degrees C to 6.8 degrees C in room temperature. For a shaded and selectively ventilated building, 2 cm of thermal insulation gives the same result as 8-10 cm of insulation for a conventional building, which is non-shaded and not ventilated. The analysis suggests that solar shading along with other two options is quite useful to development of passive cooling system to maintain indoor room air temperature lower than the conventional building.
引用
收藏
页码:60 / 75
页数:16
相关论文
共 50 条
  • [21] Envelope wall/roof thermal performance parameters for non air-conditioned buildings
    Barrios, G.
    Huelsz, G.
    Rojas, J.
    Ochoa, J. M.
    Marincic, I.
    ENERGY AND BUILDINGS, 2012, 50 : 120 - 127
  • [22] Prevalence of irritative symptoms in a nonproblem air-conditioned office building
    Muzi, G
    Abbritti, G
    Accattoli, MP
    dell'Omo, M
    INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1998, 71 (06) : 372 - 378
  • [23] Prevalence of irritative symptoms in a nonproblem air-conditioned office building
    Giacomo Muzi
    Giuseppe Abbritti
    M. Patrizia Accattoli
    Marco dell'Omo
    International Archives of Occupational and Environmental Health, 1998, 71 : 372 - 378
  • [24] Indoor suspended particulates distribution in an air-conditioned teaching building
    Huang, YC
    Yang, SH
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 1807 - 1810
  • [25] Development and application of an indoor air quality audit to an air-conditioned building in Singapore
    Cheong, KW
    Chong, KY
    BUILDING AND ENVIRONMENT, 2001, 36 (02) : 181 - 188
  • [26] HIGH PREVALENCE OF SICK BUILDING SYNDROME IN A NEW AIR-CONDITIONED BUILDING IN ITALY
    ABBRITTI, G
    MUZI, G
    ACCATTOLI, MP
    FIORDI, T
    DELLOMO, M
    COLANGELI, C
    GABRIELLI, AR
    FABBRI, T
    DALESSANDRO, A
    ARCHIVES OF ENVIRONMENTAL HEALTH, 1992, 47 (01): : 16 - 22
  • [27] Climatic influences on the energy performance of air-conditioned buildings
    Lam, JC
    ENERGY CONVERSION AND MANAGEMENT, 1999, 40 (01) : 39 - 49
  • [28] Thermal performance of domed roof in air-conditioned spaces
    Reda I.
    AbdelMessih R.N.
    Steit M.
    Mina E.M.
    Energy and Built Environment, 2024, 5 (02): : 270 - 287
  • [29] FUNCTION AND EVALUATION OF AIR-CONDITIONED LUMINAIRES .1.
    HILBERT, GS
    LICHTTECHNIK, 1976, 28 (08): : 342 - 346
  • [30] Thermal performance of non air-conditioned buildings with vaulted roofs in comparison with flat roofs
    Tang, RS
    Meir, IA
    Wu, T
    BUILDING AND ENVIRONMENT, 2006, 41 (03) : 268 - 276