Performance evaluation of multi-passive solar applications of a non air-conditioned building

被引:13
|
作者
Kumar, Rakesh [1 ]
Garg, S. N. [1 ]
Kaushik, S. C. [1 ]
机构
[1] Indian Inst Technol, Ctr Energy Studies, New Delhi 110016, India
关键词
solar shading; insulation; ACH; composite; hot and dry; warm and humid;
D O I
10.1504/IJETM.2005.006507
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper describes the performance evaluation of solar passive cooling techniques such as solar shading insulation of building components and air exchange rate. Thermal performance of the non air-conditioned building is predicted by analysing a one-dimensional numerical model. Numerical calculation has been made corresponding to three different climates, viz. composite, hot and dry and warm and humid. A decrease in the indoor temperature by about 2.5 degrees C to 4.5 degrees C is noticed for solar shading. Results modified with insulation and controlled air exchange rate show a further decrease of 4.4 degrees C to 6.8 degrees C in room temperature. For a shaded and selectively ventilated building, 2 cm of thermal insulation gives the same result as 8-10 cm of insulation for a conventional building, which is non-shaded and not ventilated. The analysis suggests that solar shading along with other two options is quite useful to development of passive cooling system to maintain indoor room air temperature lower than the conventional building.
引用
收藏
页码:60 / 75
页数:16
相关论文
共 50 条
  • [11] Sick building syndrome in air-conditioned museum
    Ali, Azlan Shah
    Chua, Shirley Jin Lin
    Bin Umar, Mohd Azlan
    MUSEUM MANAGEMENT AND CURATORSHIP, 2024, 39 (05) : 666 - 691
  • [12] Techno-environmental assessment of outdoor glazing cover of a building with multi-passive solar systems
    Jahangir, Mohammad Hossein
    Firouzabad, Mahboube Roostaei
    Ghasempour, Roghayeh
    ENERGY REPORTS, 2023, 10 : 3532 - 3544
  • [13] Ventilation characteristics of an air-conditioned office building in Singapore
    Sekhar, SC
    Tham, KW
    Cheong, D
    BUILDING AND ENVIRONMENT, 2002, 37 (03) : 241 - 255
  • [14] Lighting and energy performance of solar film coating in air-conditioned cellular offices
    Li, DHW
    Lam, JC
    Lau, CCS
    Huan, TW
    RENEWABLE ENERGY, 2004, 29 (06) : 921 - 937
  • [15] Indoor air pollution in Air-Conditioned bus and non-Air-Conditioned bus
    Husna, I. E.
    Unzilatirrizqi, Y. E. R. D.
    Sarifuddin
    Wijinurhayati, A. A.
    2ND INTERNATIONAL CONFERENCE ON ENVIRONMENT, SUSTAINABILITY ISSUES, AND COMMUNITY DEVELOPMENT, 2021, 623
  • [16] FUNCTION AND EVALUATION OF AIR-CONDITIONED LUMINAIRES (II)
    HILBERT, GS
    LICHTTECHNIK, 1976, 28 (09): : 377 - 382
  • [17] Indoor Air Quality Related to Occupancy at an Air-conditioned Public Building
    Ponsoni, Karina
    Goncalves Raddi, Maria Stella
    BRAZILIAN ARCHIVES OF BIOLOGY AND TECHNOLOGY, 2010, 53 (01) : 99 - 103
  • [18] Application of silicon solar cell on the air-conditioned jacket
    Lee, Jiyeon
    Jung, Yelee
    Cho, Ara
    Kim, Eunae
    PROCEEDINGS OF THE FIBER SOCIETY 2009 SPRING CONFERENCE, VOLS I AND II, 2009, : 1052 - 1053
  • [19] SOLAR THERMAL MODELING OF NON-AIR-CONDITIONED MULTI-ZONE BUILDING: EVALUATION OF HEAT FLUXES AND ROOM AIR TEMPERATURES
    Majali, V. S.
    Prasad, B. N.
    Bhat, A. K.
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2008, 5 (05) : 405 - 412
  • [20] THERMAL MODELING OF INTEGRATED ROOF AIR HEATER FOR PASSIVE SOLAR SPACE HEATING OF A NON-AIR-CONDITIONED BUILDING
    CHANDRA, S
    KAUSHIK, DD
    KAUSHIK, SC
    ENERGY CONVERSION AND MANAGEMENT, 1984, 24 (02) : 115 - 122