Performance evaluation of multi-passive solar applications of a non air-conditioned building

被引:13
|
作者
Kumar, Rakesh [1 ]
Garg, S. N. [1 ]
Kaushik, S. C. [1 ]
机构
[1] Indian Inst Technol, Ctr Energy Studies, New Delhi 110016, India
关键词
solar shading; insulation; ACH; composite; hot and dry; warm and humid;
D O I
10.1504/IJETM.2005.006507
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper describes the performance evaluation of solar passive cooling techniques such as solar shading insulation of building components and air exchange rate. Thermal performance of the non air-conditioned building is predicted by analysing a one-dimensional numerical model. Numerical calculation has been made corresponding to three different climates, viz. composite, hot and dry and warm and humid. A decrease in the indoor temperature by about 2.5 degrees C to 4.5 degrees C is noticed for solar shading. Results modified with insulation and controlled air exchange rate show a further decrease of 4.4 degrees C to 6.8 degrees C in room temperature. For a shaded and selectively ventilated building, 2 cm of thermal insulation gives the same result as 8-10 cm of insulation for a conventional building, which is non-shaded and not ventilated. The analysis suggests that solar shading along with other two options is quite useful to development of passive cooling system to maintain indoor room air temperature lower than the conventional building.
引用
收藏
页码:60 / 75
页数:16
相关论文
共 50 条
  • [31] Effect of exercise in air-conditioned and non-air-conditioned environment in cardiac autonomic control
    de Carvalho Cutrim, Ana L.
    Soares, Ligia
    Sevilio, Mario, Jr.
    Silva-Filho, Antonio C.
    Dias, Carlos J.
    Rodrigues, Bruno
    Veneroso, Christiano
    Mostarda, Cristiano T.
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2017, 57 (7-8): : 1080 - 1081
  • [32] MEASUREMENT OF ENVIRONMENTAL TOBACCO-SMOKE IN AN AIR-CONDITIONED OFFICE BUILDING
    PROCTOR, CJ
    WARREN, ND
    BEVAN, MAJ
    PRESENT AND FUTURE OF INDOOR AIR QUALITY, 1989, 860 : 169 - 172
  • [33] AN ANALYSIS OF STOCHASTIC PROPERTIES OF THE HEATING LOAD IN AN INTERMITTENTLY AIR-CONDITIONED BUILDING
    HOKOI, S
    MATSUMOTO, M
    ENERGY AND BUILDINGS, 1988, 11 (1-3) : 259 - 266
  • [34] OPTIMUM DISTRIBUTION OF INSULATION OVER THE WALLS AND ROOF OF AN AIR-CONDITIONED BUILDING
    DESHMUKH, MK
    SODHA, MS
    SAWHNEY, RL
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1991, 15 (04) : 275 - 288
  • [35] Multi-source synthesis - Post air-conditioned architecture
    不详
    ARCHITECTURAL DESIGN, 1997, (126) : R2 - R5
  • [36] Neural Networks Approach for Energy Consumption in Air-Conditioned Administrative Building
    Khalil, Essam E.
    Medhat, Ahmed A.
    Morkos, Samy M.
    Salem, Mohamed Y.
    ASHRAE TRANSACTIONS 2012, VOL 118, PT 1, 2012, 118 : 257 - 264
  • [37] Simulation and Analyse on Thermal Characters and Energy Consumption in Air-conditioned Building
    Qu, Ruigui
    PROCEEDINGS OF THE SECOND INTERNATIONAL CONFERENCE ON MODELLING AND SIMULATION (ICMS2009), VOL 3, 2009, : 134 - 139
  • [38] CFD study of the thermal environment in an air-conditioned train station building
    Li, Qiong
    Yoshino, Hiroshi
    Mochida, Akashi
    Lei, Bo
    Meng, Qinglin
    Zhao, Lihua
    Lun, Yufat
    BUILDING AND ENVIRONMENT, 2009, 44 (07) : 1452 - 1465
  • [39] OPTIMUM DISTRIBUTION OF INSULATION OVER VARIOUS COMPONENTS OF AN AIR-CONDITIONED BUILDING
    KUMAR, A
    ASHUTOSH, S
    SODHA, MS
    BUILDING AND ENVIRONMENT, 1989, 24 (02) : 169 - 178
  • [40] MEASUREMENTS OF ENVIRONMENTAL TOBACCO-SMOKE IN AN AIR-CONDITIONED OFFICE BUILDING
    PROCTOR, CJ
    WARREN, ND
    BEVAN, MAJ
    ENVIRONMENTAL TECHNOLOGY LETTERS, 1989, 10 (11): : 1003 - 1018