Performance evaluation of multi-passive solar applications of a non air-conditioned building

被引:13
|
作者
Kumar, Rakesh [1 ]
Garg, S. N. [1 ]
Kaushik, S. C. [1 ]
机构
[1] Indian Inst Technol, Ctr Energy Studies, New Delhi 110016, India
关键词
solar shading; insulation; ACH; composite; hot and dry; warm and humid;
D O I
10.1504/IJETM.2005.006507
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper describes the performance evaluation of solar passive cooling techniques such as solar shading insulation of building components and air exchange rate. Thermal performance of the non air-conditioned building is predicted by analysing a one-dimensional numerical model. Numerical calculation has been made corresponding to three different climates, viz. composite, hot and dry and warm and humid. A decrease in the indoor temperature by about 2.5 degrees C to 4.5 degrees C is noticed for solar shading. Results modified with insulation and controlled air exchange rate show a further decrease of 4.4 degrees C to 6.8 degrees C in room temperature. For a shaded and selectively ventilated building, 2 cm of thermal insulation gives the same result as 8-10 cm of insulation for a conventional building, which is non-shaded and not ventilated. The analysis suggests that solar shading along with other two options is quite useful to development of passive cooling system to maintain indoor room air temperature lower than the conventional building.
引用
收藏
页码:60 / 75
页数:16
相关论文
共 50 条
  • [1] Analysis and performance evaluation of a cavity roof over a non air-conditioned building
    Kumar, G.S.
    Bhardwaj, V.
    Kaushik, S.C.
    International Journal of Ambient Energy, 1997, 18 (03): : 141 - 152
  • [2] Field study of performance of solar chimney with air-conditioned building
    Khedari, J
    Rachapradit, N
    Hirunlabh, J
    ENERGY, 2003, 28 (11) : 1099 - 1114
  • [3] THERMAL PERFORMANCE OF A NON-AIR-CONDITIONED BUILDING FOR PASSIVE SOLAR AIR-CONDITIONING - EVALUATION OF ROOF COOLING SYSTEMS
    CHANDRA, S
    KAUSHIK, SC
    BANSAL, PK
    ENERGY AND BUILDINGS, 1985, 8 (01) : 51 - 69
  • [4] Ionization of air in an air-conditioned building
    Behounek, F
    Kletschka, J
    NATURE, 1938, 142 : 956 - 956
  • [5] A NATURALLY AIR-CONDITIONED BUILDING
    HAY, HR
    YELLOTT, JI
    MECHANICAL ENGINEERING, 1970, 92 (01) : 19 - &
  • [6] Wall/roof thermal performance differences between air-conditioned and non air-conditioned rooms
    Barrios, G.
    Huelsz, G.
    Rechtman, R.
    Rojas, J.
    ENERGY AND BUILDINGS, 2011, 43 (01) : 219 - 223
  • [7] A case study of energy performance for solar film coating in an air-conditioned commercial building
    Li, Danny Hin Wa
    Wong, Sai Lee
    Mak, Ada Hoi Lam
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 176 - 183
  • [8] PERFORMANCE ANALYSIS OF A SOLAR AIR-CONDITIONED VILLA IN THE ARABIAN GULF
    OSMAN, MG
    ENERGY CONVERSION AND MANAGEMENT, 1985, 25 (03) : 283 - 293
  • [9] Building energy performance of air-conditioned office buildings in Hong Kong
    Chan, RYC
    Lam, JC
    Li, DHW
    Tsang, EKW
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 985 - 992
  • [10] CONSTRUCTION AND OPERATION OF A NATURALLY AIR-CONDITIONED BUILDING
    HAY, HR
    YELLOTT, JI
    MECHANICAL ENGINEERING, 1969, 91 (03) : 66 - &