Iterative reconstructions in multiphasic CT imaging of the liver: qualitative and task-based analyses of image quality

被引:6
|
作者
Pasquier, H. [1 ,2 ]
Gardavaud, F. [3 ]
Chiaradia, M. [2 ]
Zanca, F. [4 ]
Herin, E. [2 ,5 ]
Mule, S. [2 ]
Rahmouni, A. [2 ,5 ]
Luciani, A. [2 ,5 ,6 ]
机构
[1] Univ Paris Est, Ecole Doctorale Sci Vie & Sante ED402, F-94010 Creteil, France
[2] AP HP, Grp Henri Mondor Albert Chenevier, Imagerie Med, F-94010 Creteil, France
[3] Hop Tenon, AP HP, Imagerie Med, F-75020 Paris, France
[4] GE Healthcare, DoseWatch, F-78530 Buc, France
[5] Univ Paris Est Creteil, Fac Med, F-94010 Creteil, France
[6] INSERM, IMRB, Unite U955, F-94010 Creteil, France
关键词
FILTERED BACK-PROJECTION; DIAMETER MEASUREMENT; ABDOMINAL CT; TUBE CURRENT; MODEL; PERFORMANCE; NOISE; ALGORITHM; MDCT; DETECTABILITY;
D O I
10.1016/j.crad.2018.05.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate the clinical benefits on image quality (IQ) of adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) in multiphasic liver CT compared to filtered back-projection (FBP), in patients and on phantoms using a novel task-based metric. MATERIALS AND METHODS: Image data of 65 patients who underwent a routine multiphasic liver CT during a 1-month period were reconstructed with FBP, ASIR50, ASIR80, and MBIR. IQ was assessed qualitatively by ranking the most distal hepatic artery (HA) and portal vein (PV) visible; and quantitatively by measuring contrast-to-noise ratio (CNR) of the liver parenchyma, HA and PV. IQ was compared between each reconstruction and correlated to CNR and detectability index (d') measurements computed on phantoms scanned with the same CT protocol as for patients. RESULTS: HA and PV were seen more distally on MBIR and ASIR80 compared to FBP (p <= 0.001). The CNR correlated weakly between patient and phantom (r=0.76 and 0.80 for HA and PV, respectively), whereas d' correlated strongly with the division order of HA and PV (r=0.96 and 0.95, respectively). CONCLUSION: MBIR and ASIR significantly improve the IQ of multiphasic liver CT, especially through better distal detection of HA and PV, in agreement with the adapted task-based metric d' estimated on phantoms. (C) 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:834.e9 / 834.e16
页数:8
相关论文
共 50 条
  • [31] Deep-Learning-Based Image Denoising in Imaging of Urolithiasis: Assessment of Image Quality and Comparison to State-of-the-Art Iterative Reconstructions
    Terzis, Robert
    Reimer, Robert Peter
    Nelles, Christian
    Celik, Erkan
    Caldeira, Liliana
    Heidenreich, Axel
    Storz, Enno
    Maintz, David
    Zopfs, David
    Hokamp, Nils Grosse
    DIAGNOSTICS, 2023, 13 (17)
  • [32] Task-based Evaluation of Deep Image Super-Resolution in Medical Imaging
    Kelkar, Varun A.
    Zhang, Xiaohui
    Granstedt, Jason
    Li, Hua
    Anastasio, Mark A.
    MEDICAL IMAGING 2021: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2021, 11599
  • [33] Comparison of two deep learning image reconstruction algorithms in chest CT images: A task-based image quality assessment on phantom data
    Greffier, Joel
    Frandon, Julien
    Si-Mohamed, Salim
    Dabli, Djamel
    Hamard, Aymeric
    Belaouni, Asmaa
    Akessoul, Philippe
    Besse, Francis
    Guiu, Boris
    Beregi, Jean-Paul
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2022, 103 (01) : 21 - 30
  • [34] Task-based measures of image quality and their relation to radiation dose and patient risk
    Barrett, Harrison H.
    Myers, Kyle J.
    Hoeschen, Christoph
    Kupinski, Matthew A.
    Little, Mark P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (02): : R1 - R75
  • [35] Task-Based Evaluation of Image Quality of Filtered Back Projection for Breast Tomosynthesis
    Wang, Xinying
    Mainprize, James G.
    Wu, Gang
    Yaffe, Martin J.
    DIGITAL MAMMOGRAPHY, 2010, 6136 : 106 - 113
  • [36] Fisher information and surrogate figures of merit for the task-based assessment of image quality
    Clarkson, Eric
    Shen, Fangfang
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2010, 27 (10) : 2313 - 2326
  • [37] Impact of dose reduction and the use of an advanced model-based iterative reconstruction algorithm on spectral performance of a dual-source CT system: A task-based image quality assessment
    Greffier, Joel
    Dabli, Djamel
    Hamard, Aymeric
    Akessoul, Philippe
    Belaouni, Asmaa
    Beregi, Jean-Paul
    Frandon, Julien
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2021, 102 (7-8) : 405 - 412
  • [38] Virtual monoenergetic images from dual-energy CT: systematic assessment of task-based image quality performance
    Cester, Davide
    Eberhard, Matthias
    Alkadhi, Hatem
    Euler, Andre
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (01) : 726 - +
  • [39] Task-based detectability in CT image reconstruction by filtered backprojection and penalized likelihood estimation
    Gang, Grace J.
    Stayman, J. Webster
    Zbijewski, Wojciech
    Siewerdsen, Jeffrey H.
    MEDICAL PHYSICS, 2014, 41 (08) : 260 - 278
  • [40] Impact of four kVp combinations available in a dual-source CT on the spectral performance of abdominal imaging: A task-based image quality assessment on phantom data
    Greffier, Joel
    Frandon, Julien
    Sadate, Alexandre
    Akessoul, Philippe
    Belaouni, Asmaa
    Beregi, Jean-Paul
    Dabli, Djamel
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (08): : 243 - 254