Iterative reconstructions in multiphasic CT imaging of the liver: qualitative and task-based analyses of image quality

被引:6
|
作者
Pasquier, H. [1 ,2 ]
Gardavaud, F. [3 ]
Chiaradia, M. [2 ]
Zanca, F. [4 ]
Herin, E. [2 ,5 ]
Mule, S. [2 ]
Rahmouni, A. [2 ,5 ]
Luciani, A. [2 ,5 ,6 ]
机构
[1] Univ Paris Est, Ecole Doctorale Sci Vie & Sante ED402, F-94010 Creteil, France
[2] AP HP, Grp Henri Mondor Albert Chenevier, Imagerie Med, F-94010 Creteil, France
[3] Hop Tenon, AP HP, Imagerie Med, F-75020 Paris, France
[4] GE Healthcare, DoseWatch, F-78530 Buc, France
[5] Univ Paris Est Creteil, Fac Med, F-94010 Creteil, France
[6] INSERM, IMRB, Unite U955, F-94010 Creteil, France
关键词
FILTERED BACK-PROJECTION; DIAMETER MEASUREMENT; ABDOMINAL CT; TUBE CURRENT; MODEL; PERFORMANCE; NOISE; ALGORITHM; MDCT; DETECTABILITY;
D O I
10.1016/j.crad.2018.05.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate the clinical benefits on image quality (IQ) of adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) in multiphasic liver CT compared to filtered back-projection (FBP), in patients and on phantoms using a novel task-based metric. MATERIALS AND METHODS: Image data of 65 patients who underwent a routine multiphasic liver CT during a 1-month period were reconstructed with FBP, ASIR50, ASIR80, and MBIR. IQ was assessed qualitatively by ranking the most distal hepatic artery (HA) and portal vein (PV) visible; and quantitatively by measuring contrast-to-noise ratio (CNR) of the liver parenchyma, HA and PV. IQ was compared between each reconstruction and correlated to CNR and detectability index (d') measurements computed on phantoms scanned with the same CT protocol as for patients. RESULTS: HA and PV were seen more distally on MBIR and ASIR80 compared to FBP (p <= 0.001). The CNR correlated weakly between patient and phantom (r=0.76 and 0.80 for HA and PV, respectively), whereas d' correlated strongly with the division order of HA and PV (r=0.96 and 0.95, respectively). CONCLUSION: MBIR and ASIR significantly improve the IQ of multiphasic liver CT, especially through better distal detection of HA and PV, in agreement with the adapted task-based metric d' estimated on phantoms. (C) 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:834.e9 / 834.e16
页数:8
相关论文
共 50 条
  • [41] Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging
    Prakash, P.
    Zbijewski, W.
    Gang, G. J.
    Ding, Y.
    Stayman, J. W.
    Yorkston, J.
    Carrino, J. A.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2011, 38 (10) : 5612 - 5629
  • [42] Image quality assessment of an iterative reconstruction algorithm applied to abdominal CT imaging
    Funama, Yoshinori
    Taguchi, Katsuyuki
    Utsunomiya, Daisuke
    Oda, Seitaro
    Katahira, Kazuhiro
    Tokuyasu, Shinichi
    Yamashita, Yasuyuki
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (04): : 527 - 534
  • [43] An Automated Software Tool for Task-Based Image Quality Assessment and Matching in Clinical CT Using the TG-233 Framework
    Solomon, J.
    Zhang, Y.
    Wilson, J.
    Samei, E.
    MEDICAL PHYSICS, 2018, 45 (06) : E134 - E134
  • [44] A Computer Simulation Model Observer for Task-Based Image Quality Assessment in Radiation Therapy
    Dolly, S.
    Yu, L.
    Mutic, S.
    Anastasio, M.
    Li, H.
    MEDICAL PHYSICS, 2016, 43 (06) : 3449 - 3449
  • [45] Design, fabrication, and implementation of voxel-based 3D printed textured phantoms for task-based image quality assessment in CT
    Solomon, Justin
    Ba, Alexandre
    Diao, Andrew
    Lo, Joseph
    Bier, Elianna
    Bochud, Francois
    Gehm, Michael
    Samei, Ehsan
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [46] Image quality guided iterative reconstruction for low-dose CT based on CT image statistics
    Duan, Jiayu
    Mou, Xuanqin
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (18):
  • [47] Improvements to image quality using hybrid and model-based iterative reconstructions: a phantom study
    Aurumskjold, Marie-Louise
    Ydstrom, Kristina
    Tingberg, Anders
    Soderberg, Marcus
    ACTA RADIOLOGICA, 2017, 58 (01) : 53 - 61
  • [48] Image quality of iterative reconstruction in cranial CT imaging: comparison of model-based iterative reconstruction (MBIR) and adaptive statistical iterative reconstruction (ASiR)
    S. Notohamiprodjo
    Z. Deak
    F. Meurer
    F. Maertz
    F. G. Mueck
    L. L. Geyer
    S. Wirth
    European Radiology, 2015, 25 : 140 - 146
  • [49] Image quality of iterative reconstruction in cranial CT imaging: comparison of model-based iterative reconstruction (MBIR) and adaptive statistical iterative reconstruction (ASiR)
    Notohamiprodjo, S.
    Deak, Z.
    Meurer, F.
    Maertz, F.
    Mueck, F. G.
    Geyer, L. L.
    Wirth, S.
    EUROPEAN RADIOLOGY, 2015, 25 (01) : 140 - 146
  • [50] Enhancing cardiac CT imaging quality: Precision metrics for assessing image quality for AI-powered reconstructions
    Longere, Benjamin
    Dacher, Jean-Nicolas
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2024, 105 (03) : 85 - 86